Investigation of metrics to assess vascular flow modifications for diverter device designs using hydrodynamics and angiographic studies

Intracranial aneurysm treatment with flow diverters (FD) is a new minimally invasive approach, recently approved for use in human patients. Attempts to correlate the flow reduction observed in angiograms with a parameter related to the FD structure have not been totally successful. To find the proper parameter, we investigated four porous-media flow models. The models describing the relation between the pressure drop and flow velocity that are investigated include the capillary theory linear model (CTLM), the drag force linear model (DFLM), the simple quadratic model (SQM) and the modified quadratic model (MQM). Proportionality parameters are referred to as permeability for the linear models and resistance for the quadratic ones. A two stage experiment was performed. First, we verified flow model validity by placing six different stainless-steel meshes, resembling FD structures, in known flow conditions. The best flow model was used for the second stage, where six different FD's were inserted in aneurysm phantoms and flow modification was estimated using angiographically derived time density curves (TDC). Finally, TDC peak variation was compared with the FD parameter. Model validity experiments indicated errors of: 70% for the linear models, 26% for the SQM and 7% for the MQM. The resistance calculated according to the MQM model correlated well with the contrast flow reduction. Results indicate that resistance calculated according to MQM is appropriate to characterize the FD and could explain the flow modification observed in angiograms.

[1]  Stephen Rudin,et al.  Angiographic imaging evaluation of patient-specific bifurcation-aneurysm phantom treatment with pre-shaped, self-expanding, flow-diverting stents: feasibility study , 2011, Medical Imaging.

[2]  I. Idelchik Handbook of Hydraulic Resistance, 2nd Edition , 1987 .

[3]  M. Gounis,et al.  The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms , 2002, Neurological research.

[4]  Daniel R. Bednarek,et al.  Microangiographic image-guided localization of a new asymmetric stent for treatment of cerebral aneurysms , 2005, SPIE Medical Imaging.

[5]  Ciprian N Ionita,et al.  Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents , 2004, SPIE Medical Imaging.

[6]  Adrian E. Scheidegger,et al.  The physics of flow through porous media , 1957 .

[7]  S. Rudin,et al.  Evaluation of a Second-Generation Self-Expanding Variable-Porosity Flow Diverter in a Rabbit Elastase Aneurysm Model , 2011, American Journal of Neuroradiology.

[8]  U. Wais,et al.  Age dependence of flow velocities in basal cerebral arteries. , 1988, Archives of disease in childhood.

[9]  S Rudin,et al.  Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology , 2008, SPIE Medical Imaging.

[10]  Baruch B. Lieber,et al.  Particle Image Velocimetry Assessment of Stent Design Influence on Intra-Aneurysmal Flow , 2002, Annals of Biomedical Engineering.

[11]  Jason Sherman,et al.  Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study , 2009, Medical Imaging.

[12]  E. Brundrett,et al.  Prediction of Pressure Drop for Incompressible Flow Through Screens , 1993 .

[13]  C Keleshis,et al.  Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions , 2009, Medical Imaging.

[14]  Stephen Rudin,et al.  Partially polyurethane-covered stent for cerebral aneurysm treatment. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[15]  Ciprian N. Ionita Design, x-ray image guidance and flow characterization of new asymmetric vascular stents , 2005 .

[16]  J. Happel,et al.  Low Reynolds number hydrodynamics: with special applications to particulate media , 1973 .

[17]  Stephen Rudin,et al.  Asymmetric Vascular Stent: Feasibility Study of a New Low-Porosity Patch-Containing Stent , 2008, Stroke.

[18]  J. Krejza,et al.  Transcranial color Doppler sonography of basal cerebral arteries in 182 healthy subjects: age and sex variability and normal reference values for blood flow parameters. , 1999, AJR. American journal of roentgenology.

[19]  Stephen Rudin,et al.  Assessment of contrast flow modification in aneurysms treated with closed-cell self-deploying asymmetric vascular stents (SAVS) , 2010, Medical Imaging.

[20]  Stephen Rudin,et al.  The Asymmetric Vascular Stent: Efficacy in a Rabbit Aneurysm Model , 2009, Stroke.

[21]  Daniel R. Bednarek,et al.  Investigation of new flow modifying endovascular image-guided interventional (EIGI) techniques in patient-specific aneurysm phantoms (PSAPs) using optical imaging , 2008, SPIE Medical Imaging.

[22]  Stephen Rudin,et al.  Flow modification in canine intracranial aneurysm model by an asymmetric stent: studies using digital subtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses , 2006, SPIE Medical Imaging.