Just-in-time tomography (JiTT): a new concept for image-guided radiation therapy.

Soft-tissue target motion is one of the main concerns in high-precision radiation therapy. Cone beam computed tomography (CBCT) has been developed recently to image soft-tissue targets in the treatment room and guide the radiation therapy treatment. However, due to its relatively long image acquisition time the CBCT approach cannot provide images of the target at the instant of the treatment and thus it is not adequate for imaging targets with intrafraction motion. In this note, a new approach for image-guided radiation therapy-just-in-time tomography (JiTT)-is proposed. Differing from CBCT, JiTT takes much less time to generate the needed tomographical, beam's-eye-view images of the treatment target at the right moment to guide the radiation therapy treatment.

[1]  Yasuhiro Monden Toyota Management System: Linking the Seven Key Functional Areas , 1993 .

[2]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[3]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[4]  Yoshihiro Takai,et al.  Evaluation of inter- and intrafraction organ motion during intensity modulated radiation therapy (IMRT) for localized prostate cancer measured by a newly developed on-board image-guided system. , 2005, Radiation medicine.

[5]  Günter Lauritsch,et al.  Theoretical framework for filtered back projection in tomosynthesis , 1998, Medical Imaging.

[6]  P J Biggs,et al.  A diagnostic X ray field verification device for a 10 MV linear accelerator. , 1984, International journal of radiation oncology, biology, physics.

[7]  John A. Rowlands,et al.  WE‐C‐J‐6C‐09: Cone Beam Digital Tomosynthesis (CBDT): An Alternative to Cone Beam Computed Tomography (CBCT) for Image‐Guided Radiation Therapy , 2005 .

[8]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[9]  Carlo Tognina,et al.  Megavoltage cone-beam computed tomography using a high-efficiency image receptor. , 2003, International journal of radiation oncology, biology, physics.

[10]  Gregory C Sharp,et al.  Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors , 2004, Physics in medicine and biology.

[11]  D. Kopans,et al.  Tomographic mammography using a limited number of low-dose cone-beam projection images. , 2003, Medical physics.

[12]  S Sone,et al.  Digital tomosynthesis imaging of the lung. , 1996, Radiation medicine.

[13]  C. Badea,et al.  Image quality in extended ARC filtered digital tomosynthesis , 2001 .