Accurate broadband measurement of electromagnetic tissue phantoms using open-ended coaxial systems

New technologies and devices for wireless communication networks are continually developed. In order to assess their performance, they have to be tested in realistic environments taking into account the influence of the body in wireless communications. Thus, the development of phantoms, which are synthetic materials that can emulate accurately the electromagnetic behaviour of different tissues, is mandatory. An accurate dielectric measurement of these phantoms requires using a measurement method with a low uncertainty. The openended coaxial technique is the most spread technique but its accuracy is strongly conditioned by the calibration procedure. A typical calibration is performed using an open circuit, a short circuit and water. However, this basic calibration is not the most accurate approach for measuring all kinds of materials. In this paper, an uncertainty analysis of the calibration process of openended coaxial characterization systems when a polar liquid is added to the typical calibration is provided. Measurements are performed on electromagnetically well-known liquids in the 0.5 - 8.5 GHz band. Results show that adding methanol improves the accuracy in the whole solution domain of the system, mainly when measuring phantoms that mimic high water content tissues, whereas ethanol is more suitable for measuring low water content tissue phantoms.

[1]  R. D. Pollard,et al.  An improved technique for permittivity measurements using a coaxial probe , 1997 .

[2]  Kenneth R. Foster,et al.  Noninvasive electrical characterization of materials at microwave frequencies using an open-ended coaxial line: test of an improved calibration technique , 1990 .

[3]  Narcis Cardona,et al.  Tailor-Made Tissue Phantoms Based on Acetonitrile Solutions for Microwave Applications up to 18 GHz , 2016, IEEE Transactions on Microwave Theory and Techniques.

[4]  Jan Vrba,et al.  Broadband Complex Permittivity Determination for Biomedical Applications , 2010 .

[5]  T. Hikage,et al.  Measurement of the maximum SAR in a spherical phantom when operating a mobile phone near a metallic wall , 2008, 2008 First International Symposium on Applied Sciences on Biomedical and Communication Technologies.

[6]  M. A. Stuchly,et al.  Equivalent circuit of an open-ended coaxial line in a lossy dielectric , 1982, IEEE Transactions on Instrumentation and Measurement.

[7]  S. S. Stuchly,et al.  Permittivity measurements using open-ended sensors and reference liquid calibration-an uncertainty analysis , 1992 .

[8]  Maria A. Stuchly,et al.  ANA Calibration Method for Measurements of Dielectric Properties , 1983, IEEE Transactions on Instrumentation and Measurement.

[9]  R N Clarke,et al.  Tables of the complex permittivity of dielectric reference liquids at frequencies up to 5 GHz. , 2012 .

[10]  F. E. Gardiol,et al.  Reflection of an open-ended coaxial line and application to nondestructive measurement of materials , 1981, IEEE Transactions on Instrumentation and Measurement.

[11]  Ilangko Balasingham,et al.  Experimental Path Loss Models for In-Body Communications Within 2.36-2.5 GHz , 2015, IEEE Journal of Biomedical and Health Informatics.

[12]  M. Stuchly,et al.  Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A Review , 1980, IEEE Transactions on Instrumentation and Measurement.

[13]  Weng Cho Chew,et al.  Improved calibration of a large open-ended coaxial probe for dielectric measurements , 1991 .

[14]  C C Davis,et al.  Microwave dielectric measurements of erythrocyte suspensions. , 1994, Biophysical journal.

[15]  Thomas Johnson,et al.  PERMITTIVITY MEASUREMENTS OF BIOLOGICAL SAMPLES BY AN OPEN-ENDED COAXIAL LINE , 2020, 2007.07343.

[16]  Andrzej Wolski,et al.  Theory of electromagnetic fields , 2011, 1111.4354.

[17]  Narcis Cardona,et al.  Spatial In-Body Channel Characterization Using an Accurate UWB Phantom , 2016, IEEE Transactions on Microwave Theory and Techniques.