Numerical investigations on the performance of a single-stage auto-cascade refrigerator operating with two vapor–liquid separators and environmentally benign binary refrigerants

The performance of auto-cascade refrigerator operating with two vapor–liquid separators and six binary refrigerants (R23/R134a, R23/R227ea, R23/R236fa, R170/R290, R170/R600a and R170/R600) was investigated with a new approach at the temperature level of −60°C. The results show that the pressure ratio, the composition of mixed refrigerants, the main stream ratio and the pressure level are the main factors affecting COP, which deserve a good balance in the optimization. The overall and local matching of heat capacity rates of the hot and cold refrigerants in the recuperators are both important for the improvement of COP. Among these binary refrigerants, the 0.55mol fraction of R23 for R23/R236fa and R170 for R170/R600 are the most prospective compositions in the nonflammable refrigerants and natural refrigerants for medium suction pressure compressors, respectively. The new approach employed in this paper also suggests a promising application to the optimization of the performance with multi-component refrigerants and different temperature levels.

[1]  M. Q. Gong,et al.  Performances of the mixed-gases Joule–Thomson refrigeration cycles for cooling fixed-temperature heat loads , 2004 .

[2]  Dale J. Missimer Refrigerant conversion of auto-refrigerating cascade (ARC) systems , 1997 .

[3]  Shengjun Zhang,et al.  Experimental investigation of moderately high temperature water source heat pump with non-azeotropic refrigerant mixtures , 2010 .

[4]  Omer Comakli,et al.  Determination of optimum working conditions R22 and R404A refrigerant mixtures in heat-pumps using Taguchi method , 2009 .

[5]  D. Jung,et al.  Performance of heat pumps charged with R170/R290 mixture , 2009 .

[6]  Fusheng Chen,et al.  Performance of a single-stage Linde-Hampson refrigerator operating with binary refrigerants at the temperature level of −60 °C , 2010 .

[7]  A. Rozhentsev Refrigerating machine operating characteristics under various mixed refrigerant mass charges , 2008 .

[8]  Yunting Ge,et al.  Performance simulation of refrigerated display cabinets operating with refrigerants R22 and R404A , 2008 .

[9]  A. P. Kleemenko One flow cascade cycle. , 1960 .

[10]  Dongsoo Jung,et al.  Performance of alternative refrigerants for residential air-conditioning applications , 2007 .

[11]  V. Kovalenko,et al.  Modern Trends in Designing Small-Scale Throttle-Cycle Coolers Operating with Mixed Refrigerants , 2002 .

[12]  W. B. Gosney Principles of Refrigeration , 1982 .

[13]  A. Khatri,et al.  Development of jt Coolers Operating at Cryogenic Temperatures with Nonflammable Mixed Refrigerants , 2008 .

[14]  G. Venkatarathnam Cryogenic mixed refrigerant processes , 2008 .