Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endolumen enlargement by angioplasty.

OBJECTIVES This study was designed to assess whether the spectral waveform of coronary velocity on Doppler study is characteristically altered in the presence of significant stenosis with normalization of the spectral waveform after relief of endolumen obstruction. BACKGROUND Although coronary flow reserve determinations have provided physiologic information complementary to the angiographic percent diameter narrowing, flow velocity measurements have been limited to proximal arteries with inconsistent results after angioplasty. A 12-MHz Doppler guide wire permits flow velocity determination in the proximal and distal coronary artery with fast Fourier spectral analysis. METHODS With the Doppler guide wire, proximal arterial flow velocity and flow reserve measurements in 17 angiographically normal arteries were compared with measurements in 29 significantly stenosed arteries. Proximal and distal flow velocity measurements were also obtained before and after angioplasty of the 29 abnormal arteries. Velocity spectrum was digitized to compute peak diastolic velocity, peak systolic velocity, mean velocity, diastolic/systolic velocity ratio and first third and first half flow fraction. RESULTS Compared with proximal stenosed arteries, proximal normal arteries had significantly higher peak diastolic velocity (64 +/- 26 cm/s vs. 41 +/- 26 cm/s) and higher coronary vasodilator reserve (2.3 +/- 0.8 vs. 1.6 +/- 0.7). Normal arteries had higher flows in the first third and first half of the coronary cycle (46 +/- 3% vs. 39 +/- 7% and 65 +/- 2% vs. 56 +/- 10%, respectively). Before angioplasty, coronary velocity variables were significantly lower distal than proximal to the stenosis. After angioplasty, there was a greater mean increase in distal velocities (200% vs. 90% for the proximal arteries) that resulted in near equalization of proximal and distal mean velocity and a significant reduction in proximal/distal mean velocity ratio (2.4 +/- 1.7 vs. 1.2 +/- 0.4). CONCLUSIONS Before angioplasty, abnormal coronary flow velocity dynamics are more marked distal than proximal to the stenosis. Greater increase in coronary flow velocities in the distal circulation after relief of endolumen obstruction results in a significant reduction in the proximal/distal flow velocity ratio. Thus, normalization of Doppler-derived flow velocity variables with marked reduction of the proximal/distal flow velocity ratios parallels angiographic success and may prove useful as an additional end point measurement in interventional cases with questionable angiographic findings.

[1]  M. Kern A simplified method to measure coronary blood flow velocity in patients: validation and application of a Judkins-style Doppler-tipped angiographic catheter. , 1990, American heart journal.

[2]  R. Cannon,et al.  Angina caused by reduced vasodilator reserve of the small coronary arteries. , 1983, Journal of the American College of Cardiology.

[3]  M. Kern,et al.  Alterations of phasic coronary artery flow velocity in humans during percutaneous coronary angioplasty. , 1992, Journal of the American College of Cardiology.

[4]  R. Wilson,et al.  Intracoronary papaverine: an ideal coronary vasodilator for studies of the coronary circulation in conscious humans. , 1986, Circulation.

[5]  C. White,et al.  Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis? , 1984, The New England journal of medicine.

[6]  G W Hamilton,et al.  Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. , 1974, The American journal of cardiology.

[7]  C. White,et al.  The value of lesion cross-sectional area determined by quantitative coronary angiography in assessing the physiologic significance of proximal left anterior descending coronary arterial stenoses. , 1984, Circulation.

[8]  R. Wilson,et al.  Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man. , 1985, Circulation.

[9]  F. Klocke,et al.  Measurements of coronary blood flow and degree of stenosis: current clinical implications and continuing uncertainties. , 1983, Journal of the American College of Cardiology.

[10]  S. E. Logan,et al.  On the Fluid Mechanics of Human Coronary Artery Stenosis , 1975, IEEE Transactions on Biomedical Engineering.

[11]  R. Wilson,et al.  Prediction of the physiologic significance of coronary arterial lesions by quantitative lesion geometry in patients with limited coronary artery disease. , 1987, Circulation.

[12]  S. M. Collins,et al.  The effect of coronary angioplasty on coronary flow reserve. , 1988, Circulation.

[13]  Coronary flow reserve in patients with normal coronary angiograms. , 1985, Journal of the American College of Cardiology.

[14]  H. Kennedy,et al.  Impaired coronary vasodilator reserve in the immediate postcoronary angioplasty period: analysis of coronary artery flow velocity indexes and regional cardiac venous efflux. , 1989, Journal of the American College of Cardiology.

[15]  H. M. Payne,et al.  Validation of A Doppler Guide Wire for Intravascular Measurement of Coronary Artery Flow Velocity , 1992, Circulation.

[16]  M. Kern,et al.  Intravenous adenosine: continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease. , 1991, Journal of the American College of Cardiology.

[17]  C. Hartley,et al.  Subselective measurement of coronary blood flow velocity using a steerable Doppler catheter. , 1986, Journal of the American College of Cardiology.

[18]  F. Kajiya,et al.  Analysis of flow characteristics in poststenotic regions of the human coronary artery during bypass graft surgery. , 1987, Circulation.

[19]  M. Frank,et al.  Relation among impaired coronary flow reserve, left ventricular hypertrophy and thallium perfusion defects in hypertensive patients without obstructive coronary artery disease☆ , 1990 .

[20]  S. M. Collins,et al.  Visual estimates of percent diameter coronary stenosis: "a battered gold standard". , 1988, Journal of the American College of Cardiology.

[21]  P. Yock,et al.  Assessment of severity of coronary stenoses using a Doppler catheter. Validation of a method based on the continuity equation. , 1989, Circulation.