Hands-on robotic distal interlocking in intramedullary nail fixation of femoral shaft fractures.

INTRODUCTION Intramedullary nailing has become the gold standard in the treatment of femoral shaft fractures. This procedure involves the placement of distal interlocking bolts using the freehand technique. Accurate placement of distal interlocks can be a challenging task, especially in inexperienced hands. Misplacement of distal interlocking bolts can lead to iatrogenic fracture, instability of the bone-implant construct, or even malalignment of the extremity. Repeated drilling attempts increase radiation exposure and can cause additional bony and soft tissue trauma. We hypothesize that robot-guided placement of distal interlocks is more accurate, precise, and efficient than the freehand technique. METHODS A custom-designed drill guide was mounted onto the arm of an industrial robot. We developed a special device to secure a generic block (Synbone, Malans, Switzerland) into which an intramedullary nail could be inserted in a standardized way. A metric scale allowed later measurements of the drillings. Digital images were taken from each side of the block for analysis of the drilling trajectories. The fluoroscope was adjusted to obtain perfect circles of the distal interlocking holes. The number of images necessary to achieve this was recorded. The axis was recognized automatically by using the differences in contrast between the matrix of the generic bone and the implant (intramedullary nail). The drill trajectories were then computed. The robot with the mounted drill-guide automatically moved onto the calculated trajectory. The surgeon then executed the drilling. We performed 40 robot assisted drillings in generic blocks. Freehand drilling served as our control group. RESULTS Analysis of the digital images revealed a mean deviation of 0.94 mm and 2.7° off the ideal trajectory using robotic assistance. In 100% of the cases (n = 40), the distal locking hole was hit. A mean of 8.8 images was acquired. After manual drilling, 92.5% of the distal interlocks were hit. A mean deviation of 3.66 mm and 10.36° was measured. A mean of 23.4 fluoroscopic images were needed. The differences between the two methods were statistically significant. CONCLUSION Robot-guided drilling increases the accuracy and precision of distal interlocking while reducing irradiation. Considering economical and logistical aspects, this application should be integrated with robot-guided fracture reduction.

[1]  Leo Joskowicz,et al.  Precise robot-assisted guide positioning for distal locking of intramedullary nails , 2005, IEEE Transactions on Medical Imaging.

[2]  S. Hayati,et al.  A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery , 1988, IEEE Transactions on Biomedical Engineering.

[3]  Leo Joskowicz,et al.  Bone-mounted miniature robot for surgical procedures: Concept and clinical applications , 2003, IEEE Trans. Robotics Autom..

[4]  Christian Krettek,et al.  Robot‐assisted fracture reduction using three‐dimensional intraoperative fracture visualization: An experimental study on human cadaver femora , 2010, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  K P Sherman,et al.  A computer assisted orthopaedic surgical system for distal locking of intramedullary nails , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[6]  R Phillips,et al.  Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra‐medullary nails: a valid and reliable navigation system , 2005, The international journal of medical robotics + computer assisted surgery : MRCAS.

[7]  R Phillips,et al.  Recovery of distal hole axis in intramedullary nail trajectory planning , 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  C. Krettek,et al.  A mechanical distal aiming device for distal locking in femoral nails. , 1999, Clinical orthopaedics and related research.

[9]  Mamoru Mitsuishi,et al.  Robot-assisted femoral fracture reduction: Preliminary study in patients and healthy volunteers , 2008, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[10]  T Ortmaier,et al.  Experiments on robot‐assisted navigated drilling and milling of bones for pedicle screw placement , 2006, The international journal of medical robotics + computer assisted surgery : MRCAS.

[11]  Peter Kazanzides,et al.  Force sensing and control for a surgical robot , 1992, Proceedings 1992 IEEE International Conference on Robotics and Automation.

[12]  Moshe Shoham,et al.  On rotations and translations with application to robot manipulators , 1993, Adv. Robotics.

[13]  Ralf Westphal,et al.  3D visualized robot assisted reduction of femoral shaft fractures: evaluation in exposed cadaveric bones. , 2009, Technology and health care : official journal of the European Society for Engineering and Medicine.

[14]  Guoyan Zheng,et al.  A Robust and Accurate Two-Stage Approach for Automatic Recovery of Distal Locking Holes in Computer-Assisted Intramedullary Nailing of Femoral Shaft Fractures , 2008, IEEE Transactions on Medical Imaging.

[15]  S Lindequist PINTRACE: a computer program for assessment of pin positions in routine radiographs of femoral neck fractures. , 1992, Computer methods and programs in biomedicine.

[16]  Leo Joskowicz,et al.  Robot-Assisted Distal Locking of Long Bone Intramedullary Nails: Localization, Registration, and In Vitro Experiments , 2004, MICCAI.