Quantitative Coronary Arteriography

The quantitative coronary arteriography that we provide for you will be ultimate to give preference. This reading book is your chosen book to accompany you when in your free time, in your lonely. This kind of book can help you to heal the lonely and get or add the inspirations to be more inoperative. Yeah, book as the widow of the world can be very inspiring manners. As here, this book is also created by an inspiring author that can make influences of you to do more.

[1]  P D Esser,et al.  Effect of coronary stenotic lesions on regional myocardial blood flow at rest. , 1986, Circulation.

[2]  S M Collins,et al.  Videodensitometric analysis of human coronary stenoses: validation in vivo by intraoperative high-frequency epicardial echocardiography. , 1988, Circulation.

[3]  Eckart Fleck,et al.  Erkennung und Quantifizierung von Koronarstenosen aus angiographischen Röntgenbildern , 1988, DAGM-Symposium.

[4]  E R Bates,et al.  Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterization. , 1985, The American journal of cardiology.

[5]  B. Eicker,et al.  The Improvement of Vessel Quantification with Image Processing Equipment for High Resolution Digital Angiography , 1989 .

[6]  E S Beckenbach,et al.  Computer densitometry for angiographic assessment of arterial cholesterol content and gross pathology in human atherosclerosis. , 1977, The Journal of laboratory and clinical medicine.

[7]  Raymond J. Lewis,et al.  DIGITAL RADIOGRAPHIC CORONARY ARTERY QUANTIFICATION. , 1985 .

[8]  William J. Sanders,et al.  Quantitation Of Coronary Artery Dimensions Using Digital Image Processing , 1981, Other Conferences.

[9]  J. J. Gerbrands,et al.  An on-line system for the quantitative analysis of coronary arterial segments , 1989, [1989] Proceedings. Computers in Cardiology.

[10]  G. Hutchins,et al.  Vessel Caliber and Branch‐Angle of Human Coronary Artery Branch‐Points , 1976, Circulation research.

[11]  S. M. Collins,et al.  Automated analysis of coronary arterial morphology in cineangiograms: geometric and physiologic validation in humans. , 1989, IEEE transactions on medical imaging.

[12]  Robert H. Selzer,et al.  A second look at quantitative coronary angiography: some unexpected problems , 1986 .

[13]  L. Brunton,et al.  Excitation-contraction coupling and cardiac contractile force , 1992 .

[14]  H W Fischer,et al.  Catalog of intravascular contrast media. , 1986, Radiology.

[15]  Robert H. Selzer,et al.  Computer Quantitation Of Coronary Angiograms , 1979, Other Conferences.

[16]  Johan H. C. Reiber,et al.  Improved Densitometric Assessment Of Percent Area-Stenosis From Coronary Cineangiograms , 1987, Other Conferences.

[17]  S. Ellis,et al.  Optimal detection of the progression of coronary artery disease: comparison of methods suitable for risk factor intervention trials. , 1986, Circulation.

[18]  E. Moore,et al.  Use and Approval of Antihypertensive Agents and Surrogate Endpoints for the Approval of Drugs Affecting Antiarrhythmic Heart Failure and Hypolipidemia , 1990, Developments in Cardiovascular Medicine.

[19]  S L Winters,et al.  Angiographic morphology and the pathogenesis of unstable angina pectoris. , 1985, Journal of the American College of Cardiology.

[20]  Dennis L. Parker,et al.  Three-dimensional Reconstruction and Cross-section Measurements of Coronary Arteries using ECG-Correlated Digital Coronary Arteriography , 1988 .

[21]  C. J. Slager,et al.  Quantitative Coronary and Left Ventricular Cineangiography: Methodology and Clinical Applications , 1986 .

[22]  J. Liénard,et al.  RII Geometrical Distorsion Modelling and Calibration , 1987 .

[23]  Martin A. Fischler,et al.  A General Approach to Machine Perception of Linear Structure in Imaged Data , 1983 .

[24]  E. Bolson,et al.  Quantitative Coronary Arteriography: Estimation of Dimensions, Hemodynamic Resistance, and Atheroma Mass of Coronary Artery Lesions Using the Arteriogram and Digital Computation , 1977, Circulation.

[25]  R. Kruger,et al.  Cross-sectional area measurements by digital subtraction videodensitometry. , 1986, Investigative radiology.

[26]  Paul Suetens,et al.  A knowledge-based system for the threedimensional reconstruction of the cerebral blood vessels from a pair of stereoscopic angiograms , 1988 .

[27]  M. LeFree,et al.  Automated quantitative coronary arteriography: morphologic and physiologic validation in vivo of a rapid digital angiographic method. , 1987, Circulation.

[28]  D C Levin,et al.  Complex and simple coronary artery stenoses: a new way to interpret coronary angiograms based on morphologic features of lesions. , 1987, Radiology.

[29]  Johan H. C. Reiber,et al.  Morphologic and Densitometric Analysis of Coronary Arteries , 1988 .

[30]  P. Lichtlen,et al.  Drug plasma levels and coronary vasodilation after isosorbide dinitrate chewing capsules. , 1989, European heart journal.

[31]  P J de Feyter,et al.  Change in diameter of coronary artery segments adjacent to stenosis after percutaneous transluminal coronary angioplasty: failure of percent diameter stenosis measurement to reflect morphologic changes induced by balloon dilation. , 1988, Journal of the American College of Cardiology.

[32]  Dietrich G. W. Onnasch,et al.  Korrektur magnetfeldbedingter Bildverzeichnungen in bewegten Röntgen-Bildverstärker-Fernseh-Systemen , 1989 .

[33]  J. Hamer Practical Echocardiography in the Adult , 2011, Developments in Cardiovascular Medicine.

[34]  C. J. Kooijman,et al.  Assessment of dimensions and image quality of coronary contrast catheters from cineangiograms. , 1985, Catheterization and cardiovascular diagnosis.

[35]  N Bom,et al.  Intra-arterial ultrasonic imaging for recanalization by spark erosion. , 1988, Ultrasound in medicine & biology.

[36]  H J ten Katen,et al.  Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: diameter versus densitometric area measurements. , 1984, The American journal of cardiology.

[37]  E L Bolson,et al.  Incomplete lysis of thrombus in the moderate underlying atherosclerotic lesion during intracoronary infusion of streptokinase for acute myocardial infarction: quantitative angiographic observations. , 1986, Circulation.

[38]  E. Ritman,et al.  CORONARY ANGIOGRAPHIC EXAMINATION WITH THE DYNAMIC SPATIAL RECONSTRUCTOR , 1984, Circulation.

[39]  R. Vogel,et al.  Comparison of automated edge detection and videodensitometric quantitative coronary arteriography , 1988 .

[40]  G. Mancini,et al.  Morphologic and physiologic validation of quantitative coronary arteriography utilizing digital methods , 1988 .

[41]  T Sandor,et al.  The minimum error in estimating coronary luminal cross-sectional area from cineangiographic diameter measurements. , 1983, Catheterization and cardiovascular diagnosis.

[42]  Rein Vos,et al.  Drugs Looking for Diseases: Innovative Drug Research and the Development of the Beta Blockers and the Calcium Antagonists , 1990 .

[43]  P D Esser,et al.  Quantification of relative coronary arterial stenosis by cinevideodensitometric analysis of coronary arteriograms. , 1984, Circulation.

[44]  R H Selzer,et al.  Precision and reproducibility of quantitative coronary angiography with applications to controlled clinical trials. A sampling study. , 1989, The Journal of clinical investigation.

[45]  P. Marhoff,et al.  Fast Automatic Recognition and 3D Reconstruction of the Coronary Tree from DSA-Projection Pairs , 1988 .

[46]  Kunio Doi,et al.  Automated Tracking Of The Vascular Tree In DSA Images Using A Double-Square-Box Region-Of-Search Algorithm , 1986, Other Conferences.

[47]  Johan H. C. Reiber,et al.  Early regression and late progression in coronary artery lesions in the first 3 months following coronary angioplasty , 1988 .

[48]  J. J. Gerbrands,et al.  Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms. , 1985, Circulation.

[49]  R H Selzer,et al.  Computer assessment of hemodynamic severity of coronary artery stenosis from angiograms. , 1985, Computer methods and programs in biomedicine.

[50]  Johan H. C. Reiber,et al.  New Developments in Quantitative Coronary Arteriography , 1988, Developments in Cardiovascular Medicine.

[51]  J H Grollman,et al.  Human coronary artery size during life. A cinearteriographic study. , 1973, Radiology.

[52]  Johan H. C. Reiber,et al.  Approaches towards standardization in acquisition and quantitation of arterial dimensions from cineangiograms , 1986 .

[53]  Jan J. Gerbrands,et al.  Computer assisted analysis of the severity of obstructions from coronary cineangiograms: a methodological review , 1984 .

[54]  E J Topol,et al.  Variability of quantitative digital subtraction coronary angiography before and after percutaneous transluminal coronary angioplasty. , 1987, The American journal of cardiology.

[55]  N Guggenheim,et al.  Morphometric versus densitometric assessment of coronary vasomotor tone--an overview. , 1989, European heart journal.

[56]  E. Bolson,et al.  Intrathoracic spatial location of specified coronary segments on the normal human heart. Applications in quantitative arteriography, assessment of regional risk and contraction, and anatomic display. , 1988, Circulation.

[57]  Paul D. Clayton,et al.  QUANTITATION IN CARDIAC VIDEO-DENSITOMETRY. , 1984 .

[58]  G H Reil,et al.  Influence of ionic and non-ionic radiographic contrast media on the vasomotor tone of epicardial coronary arteries. , 1989, European heart journal.

[59]  David M. Herrington,et al.  Issues of validation in quantitative coronary angiography , 1988 .

[60]  Michael T. LeFree,et al.  Digital Radiographic Assessment Of Coronary Arterial Geometric Diameter And Videodensitometric Cross-Sectional Area , 1986, Other Conferences.

[61]  H. Wollschlager,et al.  Optical distortion due to geomagnetism in quantitative angiography , 1988, Proceedings. Computers in Cardiology 1988.

[62]  L. Boxt Basic Concepts of Digital Subtraction Angiography , 1984 .

[63]  S M Collins,et al.  Videodensitometric analysis of coronary stenoses. In vivo geometric and physiologic validation in humans. , 1988, Investigative radiology.

[64]  Johan H. C. Reiber,et al.  Quality control in performing quantitative coronary arteriography , 1989 .

[65]  J. J. Gerbrands,et al.  Computer-Aided Quantitation Of The Severity Of Coronary Obstructions From Single View Cineangiograms , 1982, Other Conferences.

[66]  T. Sandor,et al.  High Precision Quantitative Angiography , 1987, IEEE Transactions on Medical Imaging.

[67]  K. Gould,et al.  AUTOMATED EVALUATION OF VESSEL DIAMETER FROM ARTERIOGRAMS. , 1983 .

[68]  D. L. Pope,et al.  Left ventricular border recognition using a dynamic search algorithm. , 1985, Radiology.

[69]  K. Gould,et al.  Assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VII. Validation of coronary flow reserve as a single integrated functional measure of stenosis severity reflecting all its geometric dimensions. , 1986, Journal of the American College of Cardiology.

[70]  W Rutishauser,et al.  On the accuracy of densitometric measurements of coronary artery stenosis based on Lambert-Beer’s absorption law , 1988 .

[71]  D. Blankenhorn,et al.  Angiographic Trials of Lipid‐Lowering Therapy , 1981 .

[72]  H. Oswald,et al.  Densitometric Correction of Vessel Diameter from Digital Arteriograms , 1988 .