Rapid vessel prototyping: vascular modeling using 3t magnetic resonance angiography and rapid prototyping technology

Object Conversion of thoracic aortic vasculature as measured by Magnetic Resonance Imaging into a real physical replica. Materials and methods Several procedural steps including data acquisition with contrast enhanced MR Angiography at 3T, data visualization and 3D computer model generation, as well as rapid prototyping were used to construct an in-vitro model of the vessel geometry. Results A rapid vessel prototyping process was implemented and used to convert complex vascular geometry of the entire thoracic aorta and major branching arteries into a real physical replica with large anatomical coverage and high spatial resolution. Conclusion Rapid vessel prototyping permits the creation of a concrete solid replica of a patient’s vascular anatomy

[1]  加藤 加代子 Accuracy of plastic replica of aortic aneurysm using 3D-CT data for transluminal stent-grafting : Experimental and clinical evaluation , 2001 .

[2]  W J Earwaker,et al.  Cerebrovascular biomodelling: a technical note. , 1999, Surgical neurology.

[3]  Norbert J. Pelc,et al.  4D Magnetic resonance velocimetry for mean velocity measurements in complex turbulent flows , 2003 .

[4]  C. Kerber,et al.  Stereolithographic vascular replicas from CT scans: choosing treatment strategies, teaching, and research from live patient scan data. , 2005, AJNR. American journal of neuroradiology.

[5]  F. Viñuela,et al.  Intraaneurysmal flow dynamics study featuring an acrylic aneurysm model manufactured using a computerized tomography angiogram as a mold. , 2001, Journal of neurosurgery.

[6]  M. Prince,et al.  Gadolinium-enhanced magnetic resonance angiography of abdominal aortic aneurysms. , 1995, Journal of vascular surgery.

[7]  Michael Markl,et al.  Time‐resolved three‐dimensional phase‐contrast MRI , 2003, Journal of magnetic resonance imaging : JMRI.

[8]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[9]  Bob S. Hu,et al.  Journal of Cardiovascular Magnetic Resonance Spiral Magnetic Resonance Coronary Angiography—direct Comparison of 1.5 Tesla vs. 3 Tesla , 2022 .

[10]  M. Prince Gadolinium-enhanced MR aortography. , 1990, Radiology.

[11]  Klaas P Pruessmann,et al.  Parallel Imaging at High Field Strength: Synergies and Joint Potential , 2004, Topics in magnetic resonance imaging : TMRI.

[12]  R A Black,et al.  Computer aided design and fabrication of models for in vitro studies of vascular fluid dynamics , 1999, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[13]  A. Ba-Ssalamah,et al.  MR Contrast Agent at High-Field MRI (3 Tesla) , 2003, Topics in magnetic resonance imaging : TMRI.

[14]  Alejandro F. Frangi,et al.  Quantitative analysis of vascular morphology from 3D MR angiograms: In vitro and in vivo results , 2001, Magnetic resonance in medicine.

[15]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[16]  David G Norris,et al.  High field human imaging , 2003, Journal of magnetic resonance imaging : JMRI.

[17]  T M Barker,et al.  Integration of 3-D medical imaging and rapid prototyping to create stereolithographic models. , 1993, Australasian physical & engineering sciences in medicine.