Inverse dynamics calculations during gait with restricted ground reaction force information from pressure insoles.

The number of consecutive strides that can be recorded in measurements of gait have been limited due to the number of force plates and dimensions of the measurement field. In addition, the feet are constrained to land on the force plates. A method to calculate the inverse dynamics from the motion and incomplete information from the ground reaction forces (GRF), vertical component and its application point, is presented and compared to the calculations based on force plate measurements. This method is based on the estimation of the three-dimensional GRF during walking with pressure insoles. RMS errors were lower than 20 W for knee joint power compared to those derived from force plate measurements. The errors were larger during double stance phase due to errors in the application point measured with the insoles. This method, with some technical improvement, could be implemented in new gait analysis protocols measuring several consecutive steps either on a treadmill or over ground, depending on the motion-measurement system, without constraining foot placement.

[1]  R. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[2]  D. Sternad,et al.  Local dynamic stability versus kinematic variability of continuous overground and treadmill walking. , 2001, Journal of biomechanical engineering.

[3]  J. Donelan,et al.  Force treadmill for measuring vertical and horizontal ground reaction forces. , 1998, Journal of applied physiology.

[4]  J. Cunningham,et al.  A comparison of vertical force and temporal parameters produced by an in-shoe pressure measuring system and a force platform. , 2000, Clinical biomechanics.

[5]  H. Hatze The fundamental problem of myoskeletal inverse dynamics and its implications. , 2002, Journal of biomechanics.

[6]  Dan Karlsson,et al.  The relative skin movement of the foot: a 2-D roentgen photogrammetry study. , 1998, Clinical biomechanics.

[7]  M. Pepper,et al.  Design, development, and characteristics of an in-shoe triaxial pressure measurement transducer utilizing a single element of piezoelectric copolymer film , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  R. Kram,et al.  A treadmill-mounted force platform. , 1989, Journal of applied physiology.

[9]  F C T van der Helm,et al.  Use of pressure insoles to calculate the complete ground reaction forces. , 2004, Journal of biomechanics.

[10]  R M Cothren,et al.  Frequency content of normal and diabetic plantar pressure profiles: implications for the selection of transducer sizes. , 1996, Journal of biomechanics.

[11]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  M Lord,et al.  Spatial resolution in plantar pressure measurement. , 1997, Medical engineering & physics.

[13]  A. Belli,et al.  A treadmill ergometer for three-dimensional ground reaction forces measurement during walking. , 2001, Journal of biomechanics.

[14]  J. Perry,et al.  Gait Analysis , 2024 .

[15]  Hendrik Johannes Luinge,et al.  Inertial sensing of human movement , 2002 .

[16]  Hans H.C.M. Savelberg,et al.  Assessment of the horizontal, fore-aft component of the ground reaction force from insole pressure patterns by using artificial neural networks , 1999 .

[17]  H J Grootenboer,et al.  An inverse dynamics model for the analysis, reconstruction and prediction of bipedal walking. , 1995, Journal of biomechanics.

[18]  J B Dingwell,et al.  A rehabilitation treadmill with software for providing real-time gait analysis and visual feedback. , 1996, Journal of biomechanical engineering.

[19]  M. Besser,et al.  Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements. , 1998, Gait & posture.

[20]  A. Leardini,et al.  Integrated pressure-force-kinematics measuring system for the characterisation of plantar foot loading during locomotion , 2000, Medical and Biological Engineering and Computing.