Microneurography as a tool to develop decoding algorithms for peripheral neuro-controlled hand prostheses

BackgroundThe usability of dexterous hand prostheses is still hampered by the lack of natural and effective control strategies. A decoding strategy based on the processing of descending efferent neural signals recorded using peripheral neural interfaces could be a solution to such limitation. Unfortunately, this choice is still restrained by the reduced knowledge of the dynamics of human efferent signals recorded from the nerves and associated to hand movements.FindingsTo address this issue, in this work we acquired neural efferent activities from healthy subjects performing hand-related tasks using ultrasound-guided microneurography, a minimally invasive technique, which employs needles, inserted percutaneously, to record from nerve fibers. These signals allowed us to identify neural features correlated with force and velocity of finger movements that were used to decode motor intentions. We developed computational models, which confirmed the potential translatability of these results showing how these neural features hold in absence of feedback and when implantable intrafascicular recording, rather than microneurography, is performed.ConclusionsOur results are a proof of principle that microneurography could be used as a useful tool to assist the development of more effective hand prostheses.

[1]  R E Burke,et al.  Spindle model responsive to mixed fusimotor inputs and testable predictions of beta feedback effects. , 2003, Journal of neurophysiology.

[2]  Luca Citi,et al.  On the use of wavelet denoising and spike sorting techniques to process electroneurographic signals recorded using intraneural electrodes , 2008, Journal of Neuroscience Methods.

[3]  Ping Zhou,et al.  Factors governing the form of the relation between muscle force and the EMG: a simulation study. , 2004, Journal of neurophysiology.

[4]  Luca Citi,et al.  Restoring Natural Sensory Feedback in Real-Time Bidirectional Hand Prostheses , 2014, Science Translational Medicine.

[5]  K. Reilly,et al.  Mapping phantom movement representations in the motor cortex of amputees. , 2006, Brain : a journal of neurology.

[6]  P. Rossini,et al.  Double nerve intraneural interface implant on a human amputee for robotic hand control , 2010, Clinical Neurophysiology.

[7]  E Henneman,et al.  Postsynatpic population potentials recorded from ventral roots perfused with isotonic sucrose: connections of groups Ia and II spindle afferent fibers with large populations of motoneurons. , 1979, Journal of neurophysiology.

[8]  D. Winter,et al.  Models of recruitment and rate coding organization in motor-unit pools. , 1993, Journal of neurophysiology.

[9]  Carlo J De Luca,et al.  Neural control of muscle force: indications from a simulation model. , 2013, Journal of neurophysiology.

[10]  Jim R. Potvin,et al.  A motor unit-based model of muscle fatigue , 2017, PLoS Comput. Biol..

[11]  Richard G. Shiavi,et al.  Analysis of raw microneurographic recordings based on wavelet de-noising technique and classification algorithm: wavelet analysis in microneurography , 2003, IEEE Transactions on Biomedical Engineering.

[12]  M. Schiefer,et al.  Fascicular Perineurium Thickness, Size, and Position Affect Model Predictions of Neural Excitation , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[13]  T. Stieglitz,et al.  A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. , 2010, Biosensors & bioelectronics.

[14]  Dario Farina,et al.  The Extraction of Neural Information from the Surface EMG for the Control of Upper-Limb Prostheses: Emerging Avenues and Challenges , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[15]  D. Burke,et al.  Voluntary activation of human motor axons in the absence of muscle afferent feedback. The control of the deafferented hand. , 1990, Brain : a journal of neurology.

[16]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[17]  Eugene M. Izhikevich,et al.  Simple model of spiking neurons , 2003, IEEE Trans. Neural Networks.

[18]  Timothy B. Curry,et al.  The use of real-time ultrasound in microneurography , 2011, Autonomic Neuroscience.

[19]  Anthony N. Burkitt,et al.  A Review of the Integrate-and-fire Neuron Model: I. Homogeneous Synaptic Input , 2006, Biological Cybernetics.

[20]  C J Heckman,et al.  Motor unit. , 2012, Comprehensive Physiology.

[21]  M E Jabaley,et al.  Internal topography of major nerves of the forearm and hand: a current view. , 1980, The Journal of hand surgery.

[22]  Mikael Bergenheim,et al.  Microneurography in Humans , 1999 .

[23]  Max Ortiz-Catalan,et al.  An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs , 2014, Science Translational Medicine.

[24]  R. Johansson,et al.  Properties of cutaneous mechanoreceptors in the human hand related to touch sensation. , 1984, Human neurobiology.

[25]  K. Horch,et al.  Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs. , 2004, The Journal of hand surgery.

[26]  Anthony N. Burkitt,et al.  A review of the integrate-and-fire neuron model: II. Inhomogeneous synaptic input and network properties , 2006, Biological Cybernetics.

[27]  Loredana Zollo,et al.  Control of Prosthetic Hands via the Peripheral Nervous System , 2016, Front. Neurosci..

[28]  J. Roll,et al.  Efferent discharges recorded from single skeletomotor and fusimotor fibres in man. , 1986, The Journal of physiology.

[29]  M. Keith,et al.  A neural interface provides long-term stable natural touch perception , 2014, Science Translational Medicine.

[30]  Sergio Silvestri,et al.  Ecological Sucking Monitoring of Newborns , 2013, IEEE Sensors Journal.

[31]  Silvestro Micera,et al.  A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems , 2005, Journal of the peripheral nervous system : JPNS.

[32]  Luca Citi,et al.  Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces , 2011, Journal of NeuroEngineering and Rehabilitation.

[33]  R. Enoka,et al.  Motor unit physiology: Some unresolved issues , 2001, Muscle & nerve.

[34]  E Knutsson,et al.  Discharge patterns in motor nerve fibres during voluntary effort in man. , 1971, Acta physiologica Scandinavica.

[35]  David J. Warren,et al.  Restoration of motor control and proprioceptive and cutaneous sensation in humans with prior upper-limb amputation via multiple Utah Slanted Electrode Arrays (USEAs) implanted in residual peripheral arm nerves , 2017, Journal of NeuroEngineering and Rehabilitation.

[36]  Andrew J Fuglevand,et al.  Distinguishing intrinsic from extrinsic factors underlying firing rate saturation in human motor units. , 2015, Journal of neurophysiology.

[37]  Donald W. Pfaff,et al.  Neuroscience in the 21st Century , 2013, Springer New York.

[38]  Stanisa Raspopovic,et al.  Framework for the Development of Neuroprostheses: From Basic Understanding by Sciatic and Median Nerves Models to Bionic Legs and Hands , 2017, Proceedings of the IEEE.

[39]  G.S. Dhillon,et al.  Direct neural sensory feedback and control of a prosthetic arm , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[40]  R. Enoka,et al.  Motor-unit synchronization increases EMG amplitude and decreases force steadiness of simulated contractions. , 2000, Journal of neurophysiology.

[41]  J. Randall Flanagan,et al.  Coding and use of tactile signals from the fingertips in object manipulation tasks , 2009, Nature Reviews Neuroscience.

[42]  S Micera,et al.  Control of Hand Prostheses Using Peripheral Information , 2010, IEEE Reviews in Biomedical Engineering.

[43]  A. G. Richardson,et al.  Modelling the effects of electric fields on nerve fibres: Influence of the myelin sheath , 2000, Medical and Biological Engineering and Computing.

[44]  John P. Cunningham,et al.  Methods for estimating neural firing rates, and their application to brain-machine interfaces , 2009, Neural Networks.

[45]  A. Monster,et al.  Isometric force production by motor units of extensor digitorum communis muscle in man. , 1977, Journal of neurophysiology.

[46]  S. Gandevia,et al.  The methodology and scope of human microneurography , 1997, Journal of Neuroscience Methods.

[47]  G. Loeb,et al.  Mathematical models of proprioceptors. II. Structure and function of the Golgi tendon organ. , 2006, Journal of neurophysiology.