Although modern ultrasound acquisition systems allow recording of 3D echocardiographic images, tracking anatomical structures from them is still challenging. In addition, since these images are typically created from information obtained across several cardiac cycles, it is not yet possible to acquire high-quality 3D images from patients presenting varying heart rhythms. In this paper, we propose a method to estimate the motion field from multi-plane echocardiographic images of the left ventricle, which are acquired simultaneously during a single cardiac cycle. The method integrates tri-plane B-mode and tissue Doppler images acquired at different rotation angles around the long axis of the left ventricle. It uses a diffeomorphic continuous spatio-temporal transformation model with a spherical data representation for a better interpolation in the circumferential direction. This framework allows exploiting the spatial relation among the acquired planes. In addition, higher temporal resolution of the transformation in the beam direction is achieved by uncoupling the estimation of the different components of the velocity field. The method was validated using a realistic synthetic dataset including healthy and ischemic cases, obtaining errors of 0.14 ± 0.09 mm for displacements, 0.96 ± 1.03% for longitudinal strain and 3.94 ± 4.38% for radial strain estimation. In addition, the method was also demonstrated on a healthy volunteer and two patients with ischemia.

[1]  Jeroen J. Bax,et al.  Usefulness of triplane tissue Doppler imaging to predict acute response to cardiac resynchronization therapy. , 2007, The American journal of cardiology.

[2]  J. D'hooge,et al.  A fast convolution-based methodology to simulate 2-Dd/3-D cardiac ultrasound images , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Hervé Delingette,et al.  Noname manuscript No. (will be inserted by the editor) Fast Parameter Calibration of a Cardiac Electromechanical Model from Medical Images based on the Unscented Transform , 2012 .

[4]  Stephane Cotin,et al.  EP4A: Software and Computer Based Simulator Research: Development and Outlook SOFA—An Open Source Framework for Medical Simulation , 2007, MMVR.

[5]  Michael Unser,et al.  Bimodal myocardial motion analysis from B-mode and tissue Doppler ultrasound , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[6]  A. Hennemuth,et al.  3D Strain Assessment in Ultrasound (Straus): A Synthetic Comparison of Five Tracking Methodologies , 2013, IEEE Transactions on Medical Imaging.

[7]  Piet Claus,et al.  Experimental assessment of a new research tool for the estimation of two-dimensional myocardial strain. , 2006, Ultrasound in medicine & biology.

[8]  M. De Craene,et al.  A Pipeline for the Generation of Realistic 3D Synthetic Echocardiographic Sequences: Methodology and Open-Access Database , 2015, IEEE Transactions on Medical Imaging.

[9]  Alejandro F. Frangi,et al.  Temporal diffeomorphic free-form deformation: Application to motion and strain estimation from 3D echocardiography , 2012, Medical Image Anal..

[10]  Zhou Chang-y Real-time 3-dimensional echocardiography technique and clinical applications , 2006 .

[11]  Masood Ahmad,et al.  Real-time three-dimensional dobutamine stress echocardiography in assessment of ischemia: comparison with two-dimensional dobutamine stress echocardiography , 2001 .

[12]  Frederik Maes,et al.  Influence of the Grid Topology of Free-Form Deformation Models on the Performance of 3D Strain Estimation in Echocardiography , 2013, FIMH.

[13]  Jan D'hooge,et al.  Comparison of real-time tri-plane and conventional 2D dobutamine stress echocardiography for the assessment of coronary artery disease. , 2006, European heart journal.

[14]  Jonas Crosby,et al.  Regional myocardial long-axis strain and strain rate measured by different tissue Doppler and speckle tracking echocardiography methods: a comparison with tagged magnetic resonance imaging. , 2009, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[15]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association , 2002, The international journal of cardiovascular imaging.

[16]  J. Nocedal,et al.  A Limited Memory Algorithm for Bound Constrained Optimization , 1995, SIAM J. Sci. Comput..

[17]  Amir A. Amini,et al.  Tissue Doppler Imaging Optical Flow (TDIOF): A Combined B-Mode and Tissue Doppler Approach for Cardiac Motion Estimation in Echocardiographic Images , 2014, IEEE Transactions on Biomedical Engineering.

[18]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. , 2002, Circulation.

[19]  Alejandro F. Frangi,et al.  Improved Myocardial Motion Estimation Combining Tissue Doppler and B-Mode Echocardiographic Images , 2014, IEEE Transactions on Medical Imaging.

[20]  Brecht Heyde,et al.  Current state of three-dimensional myocardial strain estimation using echocardiography. , 2013, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.