The effect of an enclosure retrofit on air leakage rates for a multi-unit residential case-study building

Abstract This paper presents a relatively new, simple and robust, method for air leakage testing. A thirteen-story multi-unit residential building was tested for air leakage before and after an enclosure retrofit. The building suites had a pre-retrofit NLA 50 average of 6.77 cm 2 /m 2 and an average post-retrofit NLA 50 of 2.82 cm 2 /m 2 —a 58% betterment. The effect of the retrofit on air leakage rates was assessed and compared to other multi-unit residential buildings across Canada and USA. The case study building was significantly tighter than other multi-unit residential buildings included in published studies. Recommendations were made for field-testing procedures in order to maximize the potential for accurate measured flow characteristics. Field-testing for air-tightness needs to be standardized in order for useful comparative results to be generated in order to inform future research and operational considerations for the multi-unit residential building stock across North America.

[1]  Colin Genge Controlling Air Leakage In Tall Buildings , 2009 .

[2]  John Straube,et al.  AIR LEAKAGE WITHIN MULTI-UNIT RESIDENTIAL BUILDINGS: TESTING AND IMPLICATIONS FOR BUILDING PERFORMANCE , 2009 .

[3]  Max H. Sherman,et al.  Ventilation Behavior and Household Characteristics in NewCalifornia Houses , 2006 .

[4]  D. J. Dickerhoff,et al.  Ventilation and infiltration in high-rise apartment buildings , 1996 .

[5]  Vice President,et al.  AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS INC. , 2007 .

[6]  Max H. Sherman,et al.  Building airtightness: Research and practice , 2004 .

[7]  Girma Bitsuamlak,et al.  Air infiltration through building envelopes: A review , 2012 .

[8]  Helmut E. Feustel Measurements of air permability in multizone buildings , 1990 .

[9]  Max H. Sherman,et al.  A comparison of the power law to quadratic formulations for air infiltration calculations , 1998 .

[10]  John Straube,et al.  Building science for building enclosures , 2005 .

[11]  Max H. Sherman,et al.  Uncertainties in fan pressurization measurements , 1995 .

[12]  S. Michalski Leakage prediction for buildings, cases, bags and bottles , 1994 .

[13]  Graham Finch,et al.  The Performance of Rainscreen Walls in Coastal British Columbia , 2007 .

[14]  M. P. Modera Residential duct system leakage; Magnitude, impacts, and potential for reduction , 1989 .

[15]  Amy Musser,et al.  Case studies of building envelope leakage measurement using an air-handler fan pressurisation approach , 2008 .

[16]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[17]  P. Price Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings , 2011 .

[18]  N. B. Hutcheon,et al.  Building Science for a Cold Climate , 1984 .