Good implant survival after acetabular revision with extensive impaction bone grafting and uncemented components.

AIMS This single-centre observational study aimed to describe the results of extensive bone impaction grafting of the whole acetabular cavity in combination with an uncemented component in acetabular revisions performed in a standardized manner since 1993. METHODS Between 1993 and 2013, 370 patients with a median age of 72 years (interquartile range (IQR) 63 to 79 years) underwent acetabular revision surgery. Of these, 229 were more than ten years following surgery and 137 were more than 15 years. All revisions were performed with extensive use of morcellized allograft firmly impacted into the entire acetabular cavity, followed by insertion of an uncemented component with supplementary screw fixation. All types of reoperation were captured using review of radiographs and medical charts, combined with data from the local surgical register and the Swedish Hip Arthroplasty Register. RESULTS Among patients with possible follow-up of ten and 15 years, 152 and 72 patients remained alive without revision of the acetabular component. The number of deaths was 61 and 50, respectively. Of those who died, six patients in each group had a reoperation performed before death. The number of patients with a reoperation was 22 for those with ten-year follow-up and 21 for those with 15 years of follow-up. The Kaplan-Meier implant survival rate for aseptic loosening among all 370 patients in the cohort was 96.3% (95% confidence interval (CI) 94.1 to 98.5) after ten years and 92.8% (95% CI 89.2 to 96.6) after 15 years. CONCLUSION Extensive bone impaction grafting combined with uncemented revision components appears to be a reliable method with favourable long-term survival. This technique offers the advantage of bone stock restoration and disputes the long-standing perception that uncemented components require > 50% of host bone contact for successful implant survival. Cite this article: Bone Joint J 2020;102-B(2):198-204.

[1]  R. Kerry,et al.  Long‐term results of acetabular reconstruction using irradiated allograft bone , 2018, The bone & joint journal.

[2]  G. Ullmark,et al.  A 2- to 16-Year Clinical Follow-Up of Revision Total Hip Arthroplasty Using a New Acetabular Implant Combined With Impacted Bone Allografts and a Cemented Cup. , 2017, The Journal of arthroplasty.

[3]  J. Kärrholm,et al.  Promising early results for trabecular metal acetabular components used at revision total hip arthroplasty: 42 ACETABULAR REVISIONS FOLLOWED WITH RADIOSTEREOMETRY IN A PROSPECTIVE RANDOMISED TRIAL , 2017, The bone & joint journal.

[4]  B. Waddell,et al.  Reconstruction of non‐contained acetabular defects with impaction grafting, a reinforcement mesh and a cemented polyethylene acetabular component , 2017, The bone & joint journal.

[5]  P. Aspenberg,et al.  Experimental models for cancellous bone healing in the rat , 2015, Acta orthopaedica.

[6]  Szilard Nemes,et al.  High Early Migration of the Revised Acetabular Component is a Predictor of Late cup Loosening: 312 cup Revisions followed with Radiostereometric Analysis for 2-20 Years , 2015, Hip international : the journal of clinical and experimental research on hip pathology and therapy.

[7]  F. Haddad,et al.  Acetabular impaction bone grafting in total hip replacement. , 2013, The bone & joint journal.

[8]  Shelain Patel,et al.  Initial implant stability predicts migration but not failure in cementless acetabular revision with bone grafting. , 2013, The Journal of arthroplasty.

[9]  Xianrong Zhang,et al.  Mesenchymal progenitors residing close to the bone surface are functionally distinct from those in the central bone marrow. , 2013, Bone.

[10]  Joong-Myung Lee,et al.  Acetabular revision total hip arthroplasty using an impacted morselized allograft and a cementless cup: minimum 10-year follow-up. , 2011, The Journal of arthroplasty.

[11]  E. Garcia-Cimbrelo,et al.  The Survival and Fate of Acetabular Reconstruction With Impaction Grafting for Large Defects , 2010, Clinical orthopaedics and related research.

[12]  J. Kvist,et al.  Acetabular revision with extensive allograft impaction and uncemented hydroxyapatite-coated implants. Results after 9 (7-11) years follow-up. , 2007, The Journal of arthroplasty.

[13]  I. Heyligers,et al.  High rate of failure of impaction grafting in large acetabular defects. , 2007, The Journal of bone and joint surgery. British volume.

[14]  Å. Carlsson,et al.  Catastrophic failure of an uncemented acetabular component due to high wear and osteolysisAn analysis of 154 Omnifit prostheses with mean 6-year follow-up , 2004, Acta orthopaedica Scandinavica.

[15]  J. Bechtold,et al.  The effects of hydroxyapatite coating and bone allograft on fixation of loaded experimental primary and revision implants , 2003, Acta orthopaedica Scandinavica.

[16]  E. Valstar,et al.  Factors associated with excessive migration in bone impaction hip revision surgery: a radiostereometric analysis study. , 2002, The Journal of arthroplasty.

[17]  K. Obrant,et al.  Histology of impacted bone-graft incorporation. , 2002, The Journal of arthroplasty.

[18]  A. Gross Revision Arthroplasty of the Acetabulum with Restoration of Bone Stock , 1999 .

[19]  J Kärrholm,et al.  Poor outcome of the PCA and Harris-Galante hip prostheses. Randomized study of 171 arthroplasties with 9-year follow-up. , 1999, Acta orthopaedica Scandinavica.

[20]  S. Woolson,et al.  Acetabular revision using a bone-ingrowth total hip component in patients who have acetabular bone stock deficiency. , 1996, The Journal of arthroplasty.

[21]  B. Wroblewski,et al.  Flanged acetabular components in cemented Charnley hip arthroplasty. Ten-year follow-up of 350 patients. , 1993, The Journal of bone and joint surgery. British volume.

[22]  W. Bargar,et al.  Classification and management of acetabular abnormalities in total hip arthroplasty. , 1989, Clinical orthopaedics and related research.

[23]  C. Engh,et al.  Results of cementless revision for failed cemented total hip arthroplasty. , 1988, Clinical orthopaedics and related research.

[24]  T. Slooff Bone grafting in total hip replacement for acetabular protrusion. , 1984, Acta orthopaedica Belgica.