Methods for quantitative analysis of the primary stability in uncemented hip prostheses.

Torsional loads of daily activities contribute to the failure of the primary fixation of hip prostheses. Implant torsional stability must be evaluated prior to in vivo clinical trials. Whereas previous work has investigated this phenomenon, descriptions of physiologically accurate and reproducible in vitro methodologies are rare. The present study aimed to detect and control the sources of error and variability that influence in vitro methods. A typical set-up for the analysis of primary stability of hip stems was studied. Load cycles included proximal-to-distal axial force, torque, and bending moment. The effects of loading frequency and strain distribution across the cortical bone were investigated in order to optimize testing conditions and measurement set-up. The relative shear motion at the bone-stem interface was measured transcortically using linear variable displacement transducers. The procedures developed for mounting specimens on the testing machine and for positioning sensors on the specimen were standardized and tested for reproducibility. The protocol was finally tested for repeatability and accuracy. Measurement errors were 2.3 microm between load cycles and 4.9 microm for repeated set-ups, comparing favorably with the literature.

[1]  J J Callaghan,et al.  The effect of femoral stem geometry on interface motion in uncemented porous-coated total hip prostheses. Comparison of straight-stem and curved-stem designs. , 1992, The Journal of bone and joint surgery. American volume.

[2]  L Cristofolini,et al.  Initial stability of uncemented hip stems: an in-vitro protocol to measure torsional interface motion. , 1995, Medical engineering & physics.

[3]  A. Cappello,et al.  Mechanical validation of whole bone composite tibia models. , 2000, Journal of biomechanics.

[4]  D. Davy,et al.  Telemeterized in vivo hip joint force data: A report on two patients after total hip surgery , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  J Kärrholm,et al.  Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. , 1994, The Journal of bone and joint surgery. American volume.

[6]  A Rohlmann,et al.  Is staircase walking a risk for the fixation of hip implants? , 1995, Journal of biomechanics.

[7]  L Cristofolini,et al.  Mechanical validation of whole bone composite femur models. , 1996, Journal of biomechanics.

[8]  W. Hayes,et al.  Cross-sectional geometry of Pecos Pueblo femora and tibiae--a biomechanical investigation: I. Method and general patterns of variation. , 1983, American journal of physical anthropology.

[9]  S D Cook,et al.  Hydroxylapatite coating of porous implants improves bone ingrowth and interface attachment strength. , 1992, Journal of biomedical materials research.

[10]  K. Markolf,et al.  The effect of calcar contact on femoral component micromovement. A mechanical study. , 1980, The Journal of bone and joint surgery. American volume.

[11]  L Cristofolini,et al.  A critical analysis of stress shielding evaluation of hip prostheses. , 1997, Critical reviews in biomedical engineering.

[12]  R. Balderston,et al.  Postoperative blood salvage in total knee arthroplasty using the Solcotrans autotransfusion system. , 1995, The Journal of arthroplasty.

[13]  N. Rydell Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons. , 1966, Acta orthopaedica Scandinavica.

[14]  J. J. O’Connor Load simulation problems in model testing , 1992 .

[15]  A Sarmiento,et al.  The cement mantle in total hip arthroplasty. Analysis of long-term radiographic results. , 1994, The Journal of bone and joint surgery. American volume.

[16]  P. Delincé,et al.  Two-year outcome of hydroxyapatite-coated prostheses. Two femoral prostheses retrieved at autopsy. , 1994, Acta orthopaedica Scandinavica.

[17]  H Weinans,et al.  Histological and biomechanical analysis of bone and interface reactions around hydroxyapatite-coated intramedullary implants of different stiffness: a pilot study on the goat. , 1997, Biomaterials.

[18]  M A Freeman,et al.  Torsional stability of the femoral component of hip arthroplasty. Response to an anteriorly applied load. , 1989, The Journal of bone and joint surgery. British volume.

[19]  P. Zysset,et al.  Micromotion at the Bone-Stem Interface during the Gait Cycle after Cementless Total Hip Replacement: Influence of Stem Design and Loading Level , 1996 .

[20]  P. Lachiewicz,et al.  In vitro initial fixation of porous-coated acetabular total hip components. A biomechanical comparative study. , 1989, The Journal of arthroplasty.

[21]  H Iwata,et al.  Macrophage activation and migration in interface tissue around loosening total hip arthroplasty components. , 1997, Journal of biomedical materials research.

[22]  S. Goodman,et al.  The effects of micromotion and particulate materials on tissue differentiation. Bone chamber studies in rabbits. , 1994, Acta orthopaedica Scandinavica. Supplementum.

[23]  P C McLeod,et al.  Measurements of repetitive activities of the knee. , 1975, Journal of biomechanics.

[24]  R W Mann,et al.  Contact pressures from an instrumented hip endoprosthesis. , 1989, The Journal of bone and joint surgery. American volume.

[25]  M Martens,et al.  The mechanical characteristics of the long bones of the lower extremity in torsional loading. , 1980, Journal of biomechanics.

[26]  L. Whiteside,et al.  Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission. , 1989, Clinical orthopaedics and related research.

[27]  T W Phillips,et al.  Loosening of cementless femoral stems: a biomechanical analysis of immediate fixation with loading vertical, femur horizontal. , 1991, Journal of biomechanics.

[28]  G. Chang,et al.  Intramedullary implant of plasma-sprayed hydroxyapatite coating: an interface study. , 1997, Journal of biomedical materials research.

[29]  K. Søballe,et al.  Hydroxyapatite ceramic coating for bone implant fixation. Mechanical and histological studies in dogs. , 1993, Acta orthopaedica Scandinavica. Supplementum.