Application of neural networks to predict the transient performance of a Run-Around Membrane Energy Exchanger for yearly non-stop operation

Abstract Application of soft computing methods (i.e. neural networks and genetic algorithms) for modeling and controlling the dynamic and transient behavior of systems has been increasing during the last decade. In this study, a neural network (NN) model is developed to predict the transient heat and moisture transfer performances (i.e., the sensible and latent effectivenesses) of a novel HVAC energy exchanger, called the Run-Around Membrane Energy Exchanger (RAMEE), which is able to transfer both heat and moisture between exhaust and supply air streams. The training data set for the NN model covers a wide range of outdoor conditions and system parameters and is produced using a Transient Numerical Model (TNM) that has been experimentally validated for some transient applications. Two separate NNs (one for sensible and one for latent energy transfer) each with 12 inputs and one output, are selected to represent the RAMEE. The ability of NN models to predict the performance of a given RAMEE design in different climates is numerically validated. The mean absolute difference (MAD) between the results of TNM and NN models for different locations are 0.5 °C for the sensible model and 0.2 g v /kg a for the latent model, which indicates satisfactory agreement for energy exchange calculations. These NN models are very fast and easy to use therefore, they might be used for design purposes or estimating the annual energy savings in different buildings with continuous operation and a RAMEE in their HVAC system.

[1]  R. Besant,et al.  Numerical model and effectiveness correlations for a run-around heat recovery system with combined counter and cross flow exchangers , 2009 .

[2]  Cai-Hang Liang,et al.  Conjugate heat and mass transfer in membrane-formed channels in all entry regions , 2010 .

[3]  Kenneth Levenberg A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .

[4]  H. Hemingson The impacts of outdoor air conditions and non-uniform exchanger channels on a run around membrane energy exchanger , 2010 .

[5]  Blake Erb Run-around membrane energy exchanger performance and operational control strategies , 2009 .

[6]  R. Besant,et al.  Energy wheel effectiveness: part II—correlations , 1999 .

[7]  Mihir Sen,et al.  Simulation of heat exchanger performance by artificial neural networks , 1999 .

[8]  Gongnan Xie,et al.  Performance predictions of laminar and turbulent heat transfer and fluid flow of heat exchangers having large tube-diameter and large tube-row by artificial neural networks , 2009 .

[9]  A. Bejan,et al.  Thermal Energy Storage: Systems and Applications , 2002 .

[10]  Carey J. Simonson,et al.  Transient behavior of run-around heat and moisture exchanger system. Part IІ: Sensitivity studies for a range of initial conditions , 2009 .

[11]  Soteris A. Kalogirou,et al.  Applications of artificial neural networks in energy systems , 1999 .

[12]  Li-Zhi Zhang,et al.  Fluid flow and heat mass transfer in membrane parallel-plates channels used for liquid desiccant air dehumidification , 2012 .

[13]  Li-Zhi Zhang An Analytical Solution to Heat and Mass Transfer in Hollow Fiber Membrane Contactors for Liquid Desiccant Air Dehumidification , 2011 .

[14]  Khizir Mahmud,et al.  Design and performance testing of counter-cross-flow run-around membrane energy exchanger system , 2009 .

[15]  Martin T. Hagan,et al.  Neural network design , 1995 .

[16]  R. Besant,et al.  Steady-state performance of a run-around membrane energy exchanger (RAMEE) for a range of outdoor air conditions , 2011 .

[17]  Rodney L. McClain,et al.  Heat Rate Predictions in Humid Air-Water Heat Exchangers Using Correlations and Neural Networks , 2001 .

[18]  R. Payne,et al.  Artificial neural network modelling of the thermal performance of a compact heat exchanger , 2009 .

[19]  Luisa F. Cabeza,et al.  Review on thermal energy storage with phase change: materials, heat transfer analysis and applications , 2003 .

[20]  Carey J. Simonson,et al.  Application of neural networks to predict the steady state performance of a Run-Around Membrane Energy Exchanger , 2012 .

[21]  Li-Zhi Zhang,et al.  Heat and mass transfer in a cross-flow membrane-based enthalpy exchanger under naturally formed boundary conditions , 2007 .

[22]  R. Besant,et al.  Energy wheel effectiveness: part I—development of dimensionless groups , 1999 .

[23]  Li-Zhi Zhang,et al.  Coupled heat and mass transfer in a counter flow hollow fiber membrane module for air humidification , 2011 .

[24]  Carey J. Simonson,et al.  The elastic and moisture transfer properties of polyethylene and polypropylene membranes for use in liquid-to-air energy exchangers , 2007 .

[25]  Ephraim M Sparrow,et al.  Heat and mass transfer characteristics of a rotating regenerative total energy wheel , 2007 .

[26]  Qiuwang Wang,et al.  Heat transfer analysis for shell-and-tube heat exchangers with experimental data by artificial neural networks approach , 2007 .

[27]  Anna Chiari,et al.  Performance analysis of a liquid desiccant and membrane contactor hybrid air-conditioning system , 2010 .

[28]  Y. Islamoglu,et al.  Heat transfer analysis using ANNs with experimental data for air flowing in corrugated channels , 2004 .

[29]  M. Ahmadi,et al.  Modeling the transient behavior of a run-around heat and moisture exchanger system , 2008 .

[30]  Hao Peng,et al.  Neural networks analysis of thermal characteristics on plate-fin heat exchangers with limited experimental data , 2009 .

[31]  Arnold Janssens,et al.  Evaluation of the different definitions of the convective mass transfer coefficient for water evaporation into air , 2009 .

[32]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[33]  W. Marion,et al.  User`s manual for TMY2s: Derived from the 1961--1990 National Solar Radiation Data Base , 1995 .

[34]  Lutz Prechelt,et al.  Early Stopping - But When? , 2012, Neural Networks: Tricks of the Trade.

[35]  R. Besant,et al.  Transient behavior of run-around heat and moisture exchanger system. Part І: Model formulation and verification , 2009 .

[36]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[37]  Haisheng Fan,et al.  Performance of a Run-Around System for HVAC Heat and Moisture Transfer Applications Using Cross-Flow Plate Exchangers Coupled with Aqueous Lithium Bromide , 2006 .

[38]  Carey J. Simonson,et al.  Performance testing of a counter-cross-flow run-around membrane energy exchanger (RAMEE) system for HVAC applications , 2010 .

[39]  Carey J. Simonson,et al.  Convective mass transfer coefficient for a hydrodynamically developed airflow in a short rectangular duct , 2007 .