An approach in architectural design of energy-efficient timber buildings with a focus on the optimal

The current research presents an architectural design approach to determine an optimal proportion of the glazing areas in regard to energy-efficiency of prefabricated timber-frame buildings, with a special focus on the south-oriented glazing surfaces. A parametric analysis is performed on the variation of the glazing-to-wall area ratio (AGAW) from 0% to 80% for six different exterior wall elements with different thermal properties. Modifications are performed for the main cardinal directions, while a detailed analysis is carried out only for the south facade. The impact of the presented variable parameters on the energy demand for heating and cooling is analysed with the use of the PHPP software. A basic theoretical contribution of the present research is transformation of a complex energy related problem to only one single independent variable – that of thermal transmittance of the wall elements (Uwall-value), with a view to determining the optimal glazing area size (AGAWopt) for all contemporary prefabricated timber construction systems. The main aim of the current study is to offer architects a simple and useful shortcut to energy-efficient design of prefabricated timber-frame buildings. The use of mathematical linear interpolation is therefore presented as a simple method for predicting an approximate energy demand with respect to AGAW and Uwall-values.

[1]  Ahmed Al-Salaymeh,et al.  Influence of windows on the energy balance of apartment buildings in Amman , 2010 .

[2]  Miroslav Premrov,et al.  Impact of the proportion of glazing surface in south facade on energy efficiency of prefabricated timber buildings , 2011 .

[3]  Maria Wall,et al.  Influence of window size on the energy balance of low energy houses , 2006 .

[4]  Sašo Medved,et al.  The effects of changes in the climate on the energy demands of buildings , 2008 .

[5]  Chiheb Bouden Influence of glass curtain walls on the building thermal energy consumption under Tunisian climatic conditions : The case of administrative buildings , 2007 .

[6]  Arild Gustavsen,et al.  State-of-the-Art Highly Insulating Window Frames - Research and Market Review , 2008 .

[7]  D. Arasteh,et al.  Glazing energy performance and design optimization with daylighting , 1984 .

[8]  Brian Ford,et al.  The Passivhaus standard in European warm climates: design guidelines for comfortable low energy homes , 2007 .

[9]  Mari-Louise Persson Windows of Opportunities : The Glazed Area and its Impact on the Energy Balance of Buildings , 2006 .

[10]  Philip Steadman,et al.  ESTIMATING THE EXPOSED SURFACE AREA OF THE DOMESTIC STOCK , 1987 .

[11]  Paul Joseph,et al.  Sustainable Non-Metallic Building Materials , 2010 .

[12]  Mehlika Inanici,et al.  Thermal performance optimization of building aspect ratio and south window size in five cities having different climatic characteristics of Turkey , 2000 .