Electrochemical Detection of the Neurotransmitter Dopamine by Nanoimprinted Interdigitated Electrodes and a CMOS Circuit With Enhanced Collection Efficiency

The interdigitated microelectrodes presented in this work desire to achieve a high collection efficiency for electrochemical dopamine detection by reducing the separation between electrodes. Sub-μm microelectrodes can be batch fabricated through nanoimprint lithography without relying on the expensive electron-beam lithography repeatedly. The applied reduction and oxidation potentials were determined by cyclic voltammetry at -0.2 V and 0.6 V, respectively. The measured current values agreed well with the analytic values. Measured sensitivities were 2.89 and 1.73 nA/μM for electrodes with gaps of 300 and 600 nm, respectively, and the average collection efficiency values were 97.9% and 95.4%. Signal transduction was also demonstrated by using a CMOS (complementary metal-oxide semiconductor) sensing circuit. The detectable resolution was about 0.1 μM. Nafion-coated electrodes were shown to provide a high selectivity of 41:1 with respect to ascorbic acid.

[1]  R. Murray,et al.  Micrometer-spaced platinum interdigitated array electrode: fabrication, theory, and initial use , 1985 .

[2]  N. Miura,et al.  Surface plasmon resonance biosensor for dopamine using D3 dopamine receptor as a biorecognition molecule. , 2007, Biosensors & bioelectronics.

[3]  Stephen Y. Chou,et al.  Imprint of sub-25 nm vias and trenches in polymers , 1995 .

[4]  G.K. Fedder,et al.  A low-noise low-offset capacitive sensing amplifier for a 50-/spl mu/g//spl radic/Hz monolithic CMOS MEMS accelerometer , 2004, IEEE Journal of Solid-State Circuits.

[5]  S. Sherman,et al.  Single-chip surface micromachined integrated gyroscope with 50°/h Allan deviation , 2002, IEEE J. Solid State Circuits.

[6]  M. S. Lu,et al.  Electrochemical detection of the neurotransmitter dopamine by nanoimprinted sub-μm microelectrodes and CMOS circuitry with near 100% collection efficiency , 2010 .

[7]  L. Anderson,et al.  Filar electrodes: steady-state currents and spectroelectrochemistry at twin interdigitated electrodes , 1985 .

[8]  Ralph N. Adams,et al.  Nafion-coated electrodes with high selectivity for CNS electrochemistry , 1984, Brain Research.

[9]  Hisao Tabei,et al.  Electrochemical behavior of reversible redox species at interdigitated array electrodes with different geometries: consideration of redox cycling and collection efficiency , 1990 .

[10]  Highly sensitive electrochemical microsensensors using submicrometer electrode arrays , 1995 .

[11]  T. Osaka,et al.  High efficiency electrochemical immuno sensors using 3D comb electrodes. , 2005, Biosensors & bioelectronics.

[12]  Lars Montelius,et al.  Nanoelectrochemical transducers for (bio-) chemical sensor applications fabricated by nanoimprint lithography , 2004 .

[13]  J. Jorgenson,et al.  Preparation and evaluation of slurry-packed liquid chromatography microcolumns with inner diameters from 12 to 33 μm , 1996 .

[14]  Gregory M Dittami,et al.  Electrically evoking and electrochemically resolving quantal release on a microchip. , 2010, Lab on a chip.

[15]  K. Ho,et al.  Enhancing dopamine detection using a glassy carbon electrode modified with MWCNTs, quercetin, and Nafion. , 2009, Biosensors & bioelectronics.

[16]  Tsutomu Horiuchi,et al.  Development of Nanoscale Interdigitated Array Electrode as Electrochemical Sensor Platform for Highly Sensitive Detection of Biomolecules , 2008 .

[17]  J. Ye,et al.  Fabrication and electrochemical characterization of interdigitated nanoelectrode arrays , 2005 .

[18]  Koichi Aoki,et al.  Quantitative analysis of reversible diffusion-controlled currents of redox soluble species at interdigitated array electrodes under steady-state conditions , 1988 .

[19]  G. Fedder,et al.  A Low-Noise Low-Offset Capacitive Sensing Amplifier for a 50-g = Hz Monolithic CMOS MEMS Accelerometer , 2004 .