Intravoxel incoherent motion diffusion imaging of the liver: optimal b-value subsampling and impact on parameter precision and reproducibility.

PURPOSE To increase diffusion sampling efficiency in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver by reducing the number of diffusion weightings (b-values). MATERIALS AND METHODS In this IRB approved HIPAA compliant prospective study, 53 subjects (M/F 38/15, mean age 52 ± 13 y) underwent IVIM DWI at 1.5T using 16 b-values (0-800s/mm(2)), with 14 subjects having repeat exams to assess IVIM parameter reproducibility. A biexponential diffusion model was used to quantify IVIM hepatic parameters (PF: perfusion fraction, D: true diffusion and D*: pseudo diffusion). All possible subsets of the 16 b-values were probed, with number of b values ranging from 4 to 15, and corresponding parameters were quantified for each subset. For each b-value subset, global parameter estimation error was computed against the parameters obtained with all 16 b-values and the subsets providing the lowest error were selected. Interscan estimation error was also evaluated between repeat exams to assess reproducibility of the IVIM technique in the liver. The optimal b-values distribution was selected such that the number of b-values was minimal while keeping parameter estimation error below interscan reproducibility error. RESULTS As the number of b-values decreased, the estimation error increased for all parameters, reflecting decreased precision of IVIM metrics. Using an optimal set of 4 b-values (0, 15, 150 and 800s/mm(2)), the errors were 6.5, 22.8 and 66.1% for D, PF and D* respectively. These values lie within the range of test-retest reproducibility for the corresponding parameters, with errors of 12.0, 32.3 and 193.8% for D, PF and D* respectively. CONCLUSION A set of 4 optimized b-values can be used to estimate IVIM parameters in the liver with significantly shorter acquisition time (up to 75%), without substantial degradation of IVIM parameter precision and reproducibility compared to the 16 b-value acquisition used as the reference.

[1]  Hersh Chandarana,et al.  Utility of the apparent diffusion coefficient for distinguishing clear cell renal cell carcinoma of low and high nuclear grade. , 2010, AJR. American journal of roentgenology.

[2]  H. Rusinek,et al.  Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast‐enhanced MRI alone and in combination: Preliminary experience , 2010, Journal of magnetic resonance imaging : JMRI.

[3]  D. Collins,et al.  Measurement reproducibility of perfusion fraction and pseudodiffusion coefficient derived by intravoxel incoherent motion diffusion-weighted MR imaging in normal liver and metastases , 2013, European Radiology.

[4]  Yi Wang,et al.  Diffusion-weighted MR imaging of solid and cystic lesions of the pancreas. , 2011, Radiographics : a review publication of the Radiological Society of North America, Inc.

[5]  Thorsten Feiweier,et al.  Diffusion-weighted imaging of the liver with multiple b values: effect of diffusion gradient polarity and breathing acquisition on image quality and intravoxel incoherent motion parameters--a pilot study. , 2013, Radiology.

[6]  U. Motosugi,et al.  High‐b‐value diffusion‐weighted MR imaging of hepatocellular lesions: Estimation of grade of malignancy of hepatocellular carcinoma , 2009, Journal of magnetic resonance imaging : JMRI.

[7]  B. Taouli,et al.  Diffusion-weighted MR imaging of the liver. , 2010, Radiology.

[8]  Jeong Min Lee,et al.  Evaluation of hepatic focal lesions using diffusion‐weighted MR imaging: Comparison of apparent diffusion coefficient and intravoxel incoherent motion‐derived parameters , 2014, Journal of magnetic resonance imaging : JMRI.

[9]  Chandru P Sundaram,et al.  Usefulness of diffusion-weighted imaging in the evaluation of renal masses. , 2010, AJR. American journal of roentgenology.

[10]  P. Liss,et al.  Intravoxel incoherent motion MR imaging of the kidney: pilot study. , 2013, Advances in experimental medicine and biology.

[11]  Bram Stieltjes,et al.  Toward an optimal distribution of b values for intravoxel incoherent motion imaging. , 2011, Magnetic resonance imaging.

[12]  Qun Chen,et al.  Optimization of b‐value sampling for diffusion‐weighted imaging of the kidney , 2012, Magnetic resonance in medicine.

[13]  A. Aisen,et al.  Assessment of chronic pancreatitis: utility of diffusion-weighted MR imaging with secretin enhancement. , 2009, Radiology.

[14]  Stephan E Maier,et al.  Biexponential characterization of prostate tissue water diffusion decay curves over an extended b-factor range. , 2006, Magnetic resonance imaging.

[15]  R M Henkelman,et al.  A quantitative interpretation of IVIM measurements of vascular perfusion in the rat brain , 1994, Magnetic resonance in medicine.

[16]  Chris Boesch,et al.  Functional evaluation of transplanted kidneys with diffusion-weighted and BOLD MR imaging: initial experience. , 2006, Radiology.

[17]  Berthold Kiefer,et al.  Intravoxel incoherent motion diffusion-weighted MR imaging for characterization of focal pancreatic lesions. , 2013, Radiology.

[18]  E. Scurr,et al.  Colorectal hepatic metastases: quantitative measurements using single-shot echo-planar diffusion-weighted MR imaging , 2006, European Radiology.

[19]  Bram Stieltjes,et al.  Differentiation of Pancreas Carcinoma From Healthy Pancreatic Tissue Using Multiple b-Values: Comparison of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Derived Parameters , 2009, Investigative radiology.

[20]  I. Yamada,et al.  Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. , 1999, Radiology.

[21]  A. Luciani,et al.  Liver Cirrhosis : Intravoxel Incoherent Motion MR Imaging — Pilot Study 1 , 2008 .

[22]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[23]  Daniel K Sodickson,et al.  A versatile flow phantom for intravoxel incoherent motion MRI , 2012, Magnetic resonance in medicine.

[24]  Henry Rusinek,et al.  Intravoxel incoherent motion and diffusion-tensor imaging in renal tissue under hydration and furosemide flow challenges. , 2012, Radiology.

[25]  Frederik De Keyzer,et al.  Diffusion-weighted MR imaging of kidneys in healthy volunteers and patients with parenchymal diseases: initial experience. , 2005, Radiology.

[26]  Bachir Taouli,et al.  Hepatocellular carcinoma: Detection with diffusion‐weighted versus contrast‐enhanced magnetic resonance imaging in pretransplant patients , 2012, Hepatology.

[27]  Jean-Luc Daire,et al.  Evaluation of liver diffusion isotropy and characterization of focal hepatic lesions with two single-shot echo-planar MR imaging sequences: prospective study in 66 patients. , 2003, Radiology.