Evaluation of Chlorine Decay in Drinking Water Systems for Different Flow Conditions: From Theory to Practice

An intensive study was developed to assess the influence of different flow conditions in the chlorine decay of drinking water systems based on a series of experiments tested on a loop pipe linked to the Lisbon water distribution system. Water samples and chlorine measurements were taken under three distinct flow conditions: (1) steady-state regimes; (2) combined flow situations—an initial steady-state period, followed by successive transient events and a new steady-state period; (3) isolated flow tests—steady-state flow regimes and transient flow regimes performed independently. All the tests were replicated for a typical range of Reynolds numbers in real water distribution systems. More specifically, pressure and velocity variations associated with hydraulic transients or water hammer conditions may degrade water quality. The series of results obtained in steady-state flow conditions confirmed the rate of chlorine decay increases with the Reynolds number and provided evidence that hydraulic transients have a slowing-down effect on chlorine decay rates.

[1]  A. E. Greenberg,et al.  Standard methods for the examination of water and wastewater : supplement to the sixteenth edition , 1988 .

[2]  C. F. Forster,et al.  Bulk Decay of Chlorine in Water Distribution Systems , 2003 .

[3]  R. Clark CHLORINE DEMAND AND TTHM FORMATION KINETICS: A SECOND-ORDER MODEL , 1998 .

[4]  Helena M. Ramos,et al.  Surge damping analysis in pipe systems: modelling and experiments Effet d'atténuation du coup de bélier dans les systèmes de conduits: modelation mathématique et expériences , 2004 .

[5]  Mark W. LeChevallier,et al.  Coliform Regrowth in Drinking Water: A Review , 1990 .

[6]  Bryan W. Karney,et al.  Velocity Profiles and Unsteady Pipe Friction in Transient Flow , 2000 .

[7]  Helena M. Ramos,et al.  Water Supply System Performance for Different Pipe Materials Part II: Sensitivity Analysis to Pressure Variation , 2009 .

[8]  C. F. Forster,et al.  Performance of Various Kinetic Models for Chlorine Decay , 2000 .

[9]  Stefano Alvisi,et al.  Optimal Placement of Isolation Valves in Water Distribution Systems Based on Valve Cost and Weighted Average Demand Shortfall , 2010 .

[10]  C F Forster,et al.  The decay of chlorine associated with the pipe wall in water distribution systems. , 2002, Water research.

[11]  Robert M. Clark,et al.  Effect of the distribution system on drinking-water quality , 1993 .

[12]  M. Ferrante,et al.  Small Amplitude Sharp Pressure Waves to Diagnose Pipe Systems , 2011 .

[13]  Bryan W. Karney,et al.  Velocity Profiles, Unsteady Friction Losses and Transient Modelling , 1999 .

[14]  P. Vieira,et al.  Accounting for the influence of initial chlorine concentration, TOC, iron and temperature when modelling chlorine decay in water supply , 2004 .

[15]  C. F. Forster,et al.  Factors which control bulk chlorine decay rates , 2000 .

[16]  S. T. Coelho,et al.  Dependency of bulk chlorine decay rates on flow velocity in water distribution networks , 2003 .

[17]  Helena M. Ramos,et al.  Water Supply System Performance for Different Pipe Materials Part I: Water Quality Analysis , 2008 .