Image comparison techniques for use with megavoltage imaging systems.

In this paper we describe software facilities for enabling patient positioning studies using the megavoltage imaging system developed at the Royal Marsden Hospital and Institute of Cancer Research. The study focuses on the use of the system for three purposes: patient position verification (by comparing images taken at treatment simulation with megavoltage images taken at treatment time); reproducibility studies (by analysing a set of megavoltage images); and set-up correction (by adjusting the set-up until the megavoltage image obtained at treatment registers with the simulation image). The need is discussed for suitably presented simulator images, a method of determining field boundaries and the possibility of delineating soft-tissue interfaces. Several algorithms of different types, developed specifically for the purpose of intercomparison of planar projection images, are presented. The techniques employed and their usefulness, in both the qualitative and the quantitative sense, are discussed. The results are presented of a phantom and clinical study, to evaluate the rigour and reproducibility of the algorithms. These results indicate that measurements can be made to an accuracy of about 1-2 mm, with a similar value for interobserver reproducibility for the best image comparison techniques available.

[1]  M van Herk,et al.  A matrix ionisation chamber imaging device for on-line patient setup verification during radiotherapy. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  S Shalev,et al.  Video techniques for on-line portal imaging. , 1989, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[3]  J Leong,et al.  A digital image processing system for high energy X-ray portal images. , 1984, Physics in medicine and biology.

[4]  H. Amols,et al.  The variability of clinical thermoluminescent dosimetry systems: a multi-institutional study. , 1987, Medical physics.

[5]  J C Leong,et al.  Visualization of internal motion within a treatment portal during a radiation therapy treatment. , 1987, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  H Meertens,et al.  Digital processing of high-energy photon beam images. , 1985, Medical physics.

[7]  D. G. Lewis,et al.  A linear array, scintillation crystal-photodiode detector for megavoltage imaging. , 1991, Medical physics.

[8]  S Balter,et al.  Megavoltage portal films using computed radiographic imaging with photostimulable phosphors. , 1987, Medical physics.

[9]  J Bijhold,et al.  A method for the measurement of field placement errors in digital portal images. , 1990, Physics in medicine and biology.

[10]  J. W. Epstein,et al.  On-line radiotherapy imaging with an array of fiber-optic image reducers. , 1990, International journal of radiation oncology, biology, physics.

[11]  A G Haus,et al.  Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma with extended mantle fields , 1974, Cancer.

[12]  P M Evans,et al.  Development of video frame store and distortion correction facilities for an external-beam radiotherapy treatment simulator. , 1991, The British journal of radiology.

[13]  T D Kampp,et al.  Fluoroscopic visualization of megavoltage therapeutic x ray beams. , 1980, International journal of radiation oncology, biology, physics.

[14]  J. Cox,et al.  Weekly localization films and detection of field placement errors. , 1978, International journal of radiation oncology, biology, physics.

[15]  M van Herk,et al.  A liquid ionisation detector for digital radiography of therapeutic megavoltage photon beams. , 1985, Physics in medicine and biology.

[16]  K S Lam,et al.  An on-line electronic portal imaging system for external beam radiotherapy. , 1986, The British journal of radiology.

[17]  M. Goitein,et al.  Accuracy of radiation field alignment in clinical practice. , 1985, International journal of radiation oncology, biology, physics.

[18]  P M Evans,et al.  The design of megavoltage projection imaging systems: some theoretical aspects. , 1991, Medical physics.

[19]  J. Leong,et al.  Use of digital fluoroscopy as an on-line verification device in radiation therapy. , 1986, Physics in medicine and biology.

[20]  A Fenster,et al.  A digital fluoroscopic imaging device for radiotherapy localization. , 1990, International journal of radiation oncology, biology, physics.

[21]  M van Herk,et al.  First clinical experience with a newly developed electronic portal imaging device. , 1990, International journal of radiation oncology, biology, physics.

[22]  Lawrence T. Fitzgerald,et al.  Real-time megavoltage imaging , 1987 .

[23]  K S Lam,et al.  On-line measurement of field placement errors in external beam radiotherapy. , 1987, The British journal of radiology.

[24]  A G Visser,et al.  Accuracy in radiation field alignment in head and neck cancer: a prospective study. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  M W Vannier,et al.  A method to analyze 2-dimensional daily radiotherapy portal images from an on-line fiber-optic imaging system. , 1991, International journal of radiation oncology, biology, physics.