Distribution Entropy (DistEn): A complexity measure to detect arrhythmia from short length RR interval time series

Heart rate complexity analysis is a powerful non-invasive means to diagnose several cardiac ailments. Non-linear tools of complexity measurement are indispensable in order to bring out the complete non-linear behavior of Physiological signals. The most popularly used non-linear tools to measure signal complexity are the entropy measures like Approximate entropy (ApEn) and Sample entropy (SampEn). But, these methods become unreliable and inaccurate at times, in particular, for short length data. Recently, a novel method of complexity measurement called Distribution Entropy (DistEn) was introduced, which showed reliable performance to capture complexity of both short term synthetic and short term physiologic data. This study aims to i) examine the competence of DistEn in discriminating Arrhythmia from Normal sinus rhythm (NSR) subjects, using RR interval time series data; ii) explore the level of consistency of DistEn with data length N; and iii) compare the performance of DistEn with ApEn and SampEn. Sixty six RR interval time series data belonging to two groups of cardiac conditions namely `Arrhythmia' and `NSR' have been used for the analysis. The data length N was varied from 50 to 1000 beats with embedding dimension m = 2 for all entropy measurements. Maximum ROC area obtained using ApEn, SampEn and DistEn were 0.83, 0.86 and 0.94 for data length 1000, 1000 and 500 beats respectively. The results show that DistEn undoubtedly exhibits a consistently high performance as a classification feature in comparison with ApEn and SampEn. Therefore, DistEn shows a promising behavior as bio marker for detecting Arrhythmia from short length RR interval data.

[1]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[2]  Ki H. Chon,et al.  Automatic Selection of the Threshold Value $r$ for Approximate Entropy , 2008, IEEE Transactions on Biomedical Engineering.

[3]  Dingchang Zheng,et al.  Assessing the complexity of short-term heartbeat interval series by distribution entropy , 2014, Medical & Biological Engineering & Computing.

[4]  Ong Wai Sing,et al.  Heart rate analysis in normal subjects of various age groups , 2004, Biomedical engineering online.

[5]  Nathaniel H. Hunt,et al.  The Appropriate Use of Approximate Entropy and Sample Entropy with Short Data Sets , 2012, Annals of Biomedical Engineering.

[6]  G.B. Moody,et al.  The impact of the MIT-BIH Arrhythmia Database , 2001, IEEE Engineering in Medicine and Biology Magazine.

[7]  Chengyu Liu,et al.  Comparison of different threshold values r for approximate entropy: application to investigate the heart rate variability between heart failure and healthy control groups , 2011, Physiological measurement.

[8]  E Kristal-Boneh,et al.  Heart rate variability in health and disease. , 1995, Scandinavian journal of work, environment & health.

[9]  S M Pincus,et al.  Approximate entropy as a measure of system complexity. , 1991, Proceedings of the National Academy of Sciences of the United States of America.

[10]  Weiting Chen,et al.  Measuring complexity using FuzzyEn, ApEn, and SampEn. , 2009, Medical engineering & physics.

[11]  Paul D. Bromley,et al.  The reliability of short-term measurements of heart rate variability. , 2005, International journal of cardiology.

[12]  Andreas Holzinger,et al.  Selection of entropy-measure parameters for knowledge discovery in heart rate variability data , 2014, BMC Bioinformatics.

[13]  U. Rajendra Acharya,et al.  Heart rate variability: a review , 2006, Medical and Biological Engineering and Computing.

[14]  P. Castiglioni,et al.  How the threshold “r” influences approximate entropy analysis of heart-rate variability , 2008, 2008 Computers in Cardiology.

[15]  J. Richman,et al.  Physiological time-series analysis using approximate entropy and sample entropy. , 2000, American journal of physiology. Heart and circulatory physiology.