Electrochemical As(III) whole-cell based biochip sensor.

The development of a whole-cell based sensor for arsenite detection coupling biological engineering and electrochemical techniques is presented. This strategy takes advantage of the natural Escherichia coli resistance mechanism against toxic arsenic species, such as arsenite, which consists of the selective intracellular recognition of arsenite and its pumping out from the cell. A whole-cell based biosensor can be produced by coupling the intracellular recognition of arsenite to the generation of an electrochemical signal. Hereto, E. coli was equipped with a genetic circuit in which synthesis of beta-galactosidase is under control of the arsenite-derepressable arsR-promoter. The E. coli reporter strain was filled in a microchip containing 16 independent electrochemical cells (i.e. two-electrode cell), which was then employed for analysis of tap and groundwater samples. The developed arsenic-sensitive electrochemical biochip is easy to use and outperforms state-of-the-art bacterial bioreporters assays specifically in its simplicity and response time, while keeping a very good limit of detection in tap water, i.e. 0.8ppb. Additionally, a very good linear response in the ranges of concentration tested (0.94ppb to 3.75ppb, R(2)=0.9975 and 3.75 ppb to 30ppb, R(2)=0.9991) was obtained, complying perfectly with the acceptable arsenic concentration limits defined by the World Health Organization for drinking water samples (i.e. 10ppb). Therefore, the proposed assay provides a very good alternative for the portable quantification of As (III) in water as corroborated by the analysis of natural groundwater samples from Swiss mountains, which showed a very good agreement with the results obtained by atomic absorption spectroscopy.

[1]  Julio A. Barberis,et al.  International groundwater resources law , 1986 .

[2]  Stefan Rödiger,et al.  Advances in Biochemical Engineering/Biotechnology , 2013 .

[3]  M Virta,et al.  Luminescent bacterial sensor for cadmium and lead. , 1998, Biosensors & bioelectronics.

[4]  Dan Melamed,et al.  Monitoring arsenic in the environment: a review of science and technologies with the potential for field measurements , 2005 .

[5]  J Rishpon,et al.  On-line monitoring of gene expression. , 1999, Microbiology.

[6]  Ian T. Paulsen,et al.  Environmental Microbiology , 2022, Methods in Molecular Biology.

[7]  T. S. West Analytical Chemistry , 1969, Nature.

[8]  T. MacDonald,et al.  Arsenic trioxide inhibits human cancer cell growth and tumor development in mice by blocking Hedgehog/GLI pathway. , 2011, The Journal of clinical investigation.

[9]  J. T. Clerc,et al.  Trends in analytical chemistry , 1980 .

[10]  Judith Rishpon,et al.  Electrochemical Biosensors for Pollutants in the Environment , 2007 .

[11]  J. R. van der Meer,et al.  Illuminating the detection chain of bacterial bioreporters. , 2004, Environmental microbiology.

[12]  M Virta,et al.  Recombinant luminescent bacteria for measuring bioavailable arsenite and antimonite , 1997, Applied and environmental microbiology.

[13]  Michael Berg,et al.  Bacterial bioassay for rapid and accurate analysis of arsenic in highly variable groundwater samples. , 2005, Environmental science & technology.

[14]  Shimshon Belkin,et al.  Microbial sensor cell arrays. , 2012, Current opinion in biotechnology.

[15]  J. Rishpon,et al.  Genetically engineered pfabA pfabR bacteria: an electrochemical whole cell biosensor for detection of water toxicity. , 2006, Analytical chemistry.

[16]  S. Daunert,et al.  Sensing antimonite and arsenite at the subattomole level with genetically engineered bioluminescent bacteria. , 1997, Analytical chemistry.

[17]  Jan Roelof van der Meer,et al.  Development of a microfluidics biosensor for agarose-bead immobilized Escherichia coli bioreporter cells for arsenite detection in aqueous samples. , 2011, Lab on a chip.

[18]  Yosi Shacham-Diamand,et al.  Electrochemical detection of biological reactions using a novel nano-bio-chip array , 2006 .

[19]  Water Research , 1961, Nature.

[20]  Hauke Harms,et al.  Internal arsenite bioassay calibration using multiple bioreporter cell lines , 2007, Microbial biotechnology.

[21]  S. Eykyn Microbiology , 1950, The Lancet.

[22]  G. Raber,et al.  Does the determination of inorganic arsenic in rice depend on the method , 2011 .

[23]  J. C. Bevington,et al.  Chemical Reviews , 1970, Nature.

[24]  C. Dolea,et al.  World Health Organization , 1949, International Organization.

[25]  Mohammad Sohel Rahman,et al.  Effectiveness and reliability of arsenic field testing kits: are the million dollar screening projects effective or not? , 2002, Environmental science & technology.

[26]  Eliora Z Ron,et al.  Biosensing environmental pollution. , 2007, Current opinion in biotechnology.

[27]  Jan Roelof van der Meer,et al.  Development of a set of simple bacterial biosensors for quantitative and rapid measurements of arsenite and arsenate in potable water. , 2003, Environmental science & technology.

[28]  S. Kounaves,et al.  Voltammetric measurement of arsenic in natural waters. , 2002, Talanta.

[29]  C. Holding Lab on a chip , 2004, Genome Biology.

[30]  Hauke Harms,et al.  Field testing of arsenic in groundwater samples of Bangladesh using a test kit based on lyophilized bioreporter bacteria. , 2012, Environmental science & technology.

[31]  V. N. Paunov,et al.  Rapid and direct magnetization of GFP-reporter yeast for micro-screening systems. , 2010, Biosensors & bioelectronics.

[32]  Sylvia Daunert,et al.  Bacteria-based chemiluminescence sensing system using β-galactosidase under the control of the ArsR regulatory protein of the ars operon , 1998 .

[33]  R. Swarup,et al.  Environmental Science and Technology , 1998 .

[34]  M. Valko,et al.  Arsenic: toxicity, oxidative stress and human disease , 2011, Journal of applied toxicology : JAT.

[35]  Genbank,et al.  APPLIED AND ENVIRONMENTAL MICROBIOLOGY , 2008, Applied and Environmental Microbiology.

[36]  J Rishpon,et al.  Online and in situ monitoring of environmental pollutants: electrochemical biosensing of cadmium. , 2000, Environmental microbiology.

[37]  Ted M. Lakowski,et al.  Analytical Biochemistry , 1960, Nature.

[38]  G. Barrett,et al.  Genetically engineered whole-cell sensing systems: coupling biological recognition with reporter genes. , 2000, Chemical reviews.

[39]  Wei Wan,et al.  Effects of water chemistry on arsenic removal from drinking water by electrocoagulation. , 2011, Water research.

[40]  H. Pfeifer,et al.  Dispersion of natural arsenic in the Malcantone watershed, Southern Switzerland: field evidence for repeated sorption–desorption and oxidation–reduction processes , 2004 .

[41]  Yosi Shacham-Diamand,et al.  Novel integrated electrochemical nano-biochip for toxicity detection in water. , 2005, Nano letters.

[42]  Dayi Zhang,et al.  Functionalization of whole‐cell bacterial reporters with magnetic nanoparticles , 2010, Microbial biotechnology.

[43]  Eliora Z Ron,et al.  Electrochemical cell-based sensors. , 2010, Advances in biochemical engineering/biotechnology.

[44]  Jan Roelof van der Meer,et al.  Analysis of bioavailable arsenic in rice with whole cell living bioreporter bacteria. , 2007, Journal of agricultural and food chemistry.

[45]  S. Belkin,et al.  Where microbiology meets microengineering: design and applications of reporter bacteria , 2010, Nature Reviews Microbiology.

[46]  Xiangqin Cui,et al.  Sensors and Actuators B , 2003 .

[47]  S. Daunert,et al.  Genetically engineered bacteria: electrochemical sensing systems for antimonite and arsenite. , 1997, Analytical chemistry.

[48]  Peter Schieberle,et al.  Targeted Metabolomics: a new section in the Journal of Agricultural and Food Chemistry. , 2014, Journal of agricultural and food chemistry.

[49]  Eliora Z Ron,et al.  Monitoring aromatic hydrocarbons by whole cell electrochemical biosensors. , 2004, Analytical biochemistry.