Quantum-inspired detection for spectral domain optical coherence tomography.

Intensity levels allowed by safety standards (ICNIRP or ANSI) limit the amount of light that can be used in a clinical setting to image highly scattering or absorptive tissues with optical coherence tomography (OCT). To achieve high-sensitivity imaging at low intensity levels, we adapt a detection scheme-which is used in quantum optics for providing information about spectral correlations of photons-into a standard spectral domain OCT system. This detection scheme is based on the concept of dispersive Fourier transformation, where a fiber introduces a wavelength-dependent time delay measured by a single-pixel detector, usually a high-speed photoreceiver. Here, we use a fast superconducting single-photon detector SSPD as a single-pixel detector and obtain images of a glass stack and a slice of onion at the intensity levels of the order of 10 pW. We also provide a formula for a depth-dependent sensitivity falloff in such a detection scheme, which can be treated as a temporal equivalent of diffraction-grating-based spectrometers.

[1]  W. Drexler,et al.  In vivo retinal optical coherence tomography at 1040 nm - enhanced penetration into the choroid. , 2005, Optics express.

[2]  Dug Young Kim,et al.  Ultra-high-speed optical coherence tomography with a stretched pulse supercontinuum source. , 2006, Optics express.

[3]  Lingfeng Yu,et al.  Improved lateral resolution in optical coherence tomography by digital focusing using two-dimensional numerical diffraction method. , 2007, Optics express.

[4]  A. Rollins,et al.  Analytical model of spectrometer-based two-beam spectral interferometry. , 2007, Applied optics.

[5]  A. Rollins,et al.  Optical Design for OCT , 2008 .

[6]  C. Silberhorn,et al.  Fibre assisted single photon spectrograph , 2009, CLEO/Europe - EQEC 2009 - European Conference on Lasers and Electro-Optics and the European Quantum Electronics Conference.

[7]  K. Goda,et al.  Theory of amplified dispersive Fourier transformation , 2009 .

[8]  Ramiro S. Maldonado,et al.  The use of optical coherence tomography in intraoperative ophthalmic imaging. , 2011, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[9]  K. Goda,et al.  High-throughput optical coherence tomography at 800 nm. , 2012, Optics express.

[10]  K. Goda,et al.  Dispersive Fourier transformation for fast continuous single-shot measurements , 2013, Nature Photonics.

[11]  M. Wojtkowski,et al.  Spectrometer calibration for spectroscopic Fourier domain optical coherence tomography. , 2016, Biomedical optics express.

[12]  R. Leitgeb,et al.  Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited]. , 2017, Biomedical optics express.

[13]  Zach DeVito,et al.  Opt , 2017 .

[14]  George Nehmetallah,et al.  Methods to assess sensitivity of optical coherence tomography systems. , 2017, Biomedical optics express.

[15]  Andrew J. Reader,et al.  Deep Learning for Suppression of Resolution-Recovery Artefacts in MLEM PET Image Reconstruction , 2017, 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[16]  Hiroshi Ishikawa,et al.  Retinal optical coherence tomography image enhancement via deep learning. , 2018, Biomedical optics express.

[17]  A single photon detection system for the spectrum range up to 2300 nm , 2018 .

[18]  A. Divochiy,et al.  Single photon detection system for visible and infrared spectrum range. , 2018, Optics letters.

[19]  Chengbo Li,et al.  Coherent noise attenuation using machine learning techniques for land seismic processing , 2019 .

[20]  Xinjian Chen,et al.  DeSpecNet: a CNN-based method for speckle reduction in retinal optical coherence tomography images , 2019, Physics in medicine and biology.

[21]  Chi Zhang,et al.  Calibration-free time-stretch optical coherence tomography with large imaging depth. , 2019, Optics letters.