CT-based True- and False-Lumen Segmentation in Type B Aortic Dissection Using Machine Learning.

Purpose To develop a segmentation pipeline for segmentation of aortic dissection CT angiograms into true and false lumina on multiplanar reformations (MPRs) perpendicular to the aortic centerline and derive quantitative morphologic features, specifically aortic diameter and true- or false-lumen cross-sectional area. Materials and Methods An automated segmentation pipeline including two convolutional neural network (CNN) segmentation algorithms was developed. The algorithm derives the aortic centerline, generates MPRs orthogonal to the centerline, and segments the true and false lumina. A total of 153 CT angiograms obtained from 45 retrospectively identified patients (mean age, 50 years; range, 22-79 years) were used to train (n = 103), validate (n = 22), and test (n = 28) the CNN pipeline. Accuracy was evaluated by using the Dice similarity coefficient (DSC). Segmentations were then used to derive the maximal diameter of test-set patients and cross-sectional area profiles of the true and false lumina. Results The segmentation pipeline yielded a mean DSC of 0.873 ± 0.056 for the true lumina and 0.894 ± 0.040 for the false lumina of test-set cases. Automated maximal diameter measurements correlated well with manual measurements (R 2 = 0.95). Profiles of cross-sectional diameter, true-lumen area, and false-lumen area over several follow-up examinations were derived. Conclusion A segmentation pipeline was used to accurately identify true and false lumina on CT angiograms of aortic dissection. These segmentations can be used to obtain diameter and other morphologic parameters for surveillance and risk stratification.Supplemental material is available for this article.© RSNA, 2020.

[1]  Rangasami L. Kashyap,et al.  Building Skeleton Models via 3-D Medial Surface/Axis Thinning Algorithms , 1994, CVGIP Graph. Model. Image Process..

[2]  J. Elefteriades Thoracic aortic aneurysm: reading the enemy's playbook. , 2008, Current problems in cardiology.

[3]  Raúl San José Estépar,et al.  Automated quantitative 3D analysis of aorta size, morphology, and mural calcification distributions. , 2015, Medical physics.

[4]  K. Eagle,et al.  Current evidence in predictors of aortic growth and events in acute type B aortic dissection , 2018, Journal of vascular surgery.

[5]  Anthony P. Reeves,et al.  Automated aorta segmentation in low-dose chest CT images , 2014, International Journal of Computer Assisted Radiology and Surgery.

[6]  Toshiro Ito,et al.  New predictor of aortic enlargement in uncomplicated type B aortic dissection based on elliptic Fourier analysis , 2017, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[7]  M. Mcmahon,et al.  Multidetector CT of Aortic Dissection: A Pictorial Review. , 2010, Radiographics : a review publication of the Radiological Society of North America, Inc.

[8]  C Karmonik,et al.  Elevated Wall Shear Stress in Aortic Type B Dissection May Relate to Retrograde Aortic Type A Dissection: A Computational Fluid Dynamics Pilot Study. , 2017, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[9]  Cheng Wang,et al.  Towards Automatic Measurement of Type B Aortic Dissection Parameters: Methods, Applications and Perspective , 2018, CVII-STENT/LABELS@MICCAI.

[10]  Thoracic aorta. , 1999, Radiology.

[11]  D. C. Miller,et al.  Aortic growth and development of partial false lumen thrombosis are associated with late adverse events in type B aortic dissection. , 2019, The Journal of thoracic and cardiovascular surgery.

[12]  Philippe C. Cattin,et al.  Automatic Segmentation of the Aortic Dissection Membrane from 3D CTA Images , 2006, MIAR.

[13]  T. Luebke,et al.  Type B Aortic Dissection , 2014, AORTA.

[14]  Noboru Niki,et al.  Automated assessment of aortic and main pulmonary arterial diameters using model-based blood vessel segmentation for predicting chronic thromboembolic pulmonary hypertension in low-dose CT lung screening , 2018, Medical Imaging.

[15]  Bert Jüttler,et al.  Computation of rotation minimizing frames , 2008, TOGS.

[16]  Karl Krissian,et al.  Semi-automatic segmentation and detection of aorta dissection wall in MDCT angiography , 2014, Medical Image Anal..

[17]  A. Karthikesalingam,et al.  A systematic review of aortic remodeling after endovascular repair of type B aortic dissection: methods and outcomes. , 2014, The Annals of thoracic surgery.

[18]  A. England,et al.  Variability of vascular CT measurement techniques used in the assessment abdominal aortic aneurysms , 2010 .