Medical applications with synchrotron radiation in Japan.

In Japan, various medical applications of synchrotron X-ray imaging, such as angiography, monochromatic X-ray computed tomography (CT), radiography and radiation therapy, are being developed. In particular, coronary arteriography (CAG) is quite an important clinical application of synchrotron radiation. Using a two-dimensional imaging method, the first human intravenous CAG was carried out at KEK in May 1996; however, further improvements of image quality are required in clinical practice. On the other hand, two-dimensional aortographic CAG revealed canine coronary arteries as clearly as those on selective CAG, and coronary arteries less than 0.2 mm in diameter. Among applications of synchrotron radiation to X-ray CT, phase-contrast X-ray CT and fluorescent X-ray CT are expected to be very interesting future applications of synchrotron radiation. For actual clinical applications of synchrotron radiation, a medical beamline and a laboratory are now being constructed at SPring-8 in Harima.

[1]  A. Momose,et al.  Phase-contrast radiographs of nonstained rat cerebellar specimen. , 1995, Medical physics.

[2]  William Thomlinson,et al.  Multiple energy computed tomography (MECT) at the NSLS: Status report , 1995 .

[3]  D N Slatkin,et al.  Single-and dual-energy CT with monochromatic synchrotron x-rays. , 1997, Physics in medicine and biology.

[4]  江橋 節郎,et al.  Handbook on synchrotron radiation , 1983 .

[5]  Britton Chance,et al.  Synchrotron radiation in the biosciences , 2005 .

[6]  T Takeda,et al.  Dynamic intravenous coronary arteriography using synchrotron radiation and its application to the measurement of coronary blood flow. , 1997, Japanese circulation journal.

[7]  Atsushi Momose,et al.  Phase-contrast x-ray computed tomography for observing biological specimens and organic materials , 1995 .

[8]  L. Grodzins,et al.  Fluorescence tomography using synchrotron radiation at the NSLS , 1987 .

[9]  Tetsuya Yuasa,et al.  Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decomposition , 1997 .

[10]  M. Ando,et al.  Real time K‐edge subtraction x‐ray imaging , 1989 .

[11]  William Thomlinson,et al.  Effects of spatial resolution and spectral purity on transvenous coronary angiography images , 1995 .

[12]  Tohoru Takeda Preliminary experiment of the fluorescent X-ray computed tomography with synchrotron radiation , 1994 .

[13]  Hidezo Mori,et al.  Visualization of Penetrating Transmural Arteries In Situ by Monochromatic Synchrotron Radiation , 1994, Circulation.

[14]  Tetsuya Yuasa,et al.  Incoherent-scatter computed tomography with monochromatic synchrotron x ray: feasibility of multi-CT imaging system for simultaneous measurement-of fluorescent and incoherent scatter x rays , 1997 .

[15]  T Takeda,et al.  High Spatial Resolution CT with a Synchrotron Radiation System , 1994, Journal of computer assisted tomography.