Investigation of the chemical stability of the laser-induced fluorescence tracers acetone, diethylketone, and toluene under IC engine conditions using Raman spectroscopy.

This paper reports on an investigation of the chemical stability of the common laser-induced fluorescence (LIF) tracers acetone, diethylketone, and toluene. Stability is analyzed using linear Raman spectroscopy inside a heated pressure cell with optical access, which is used for the LIF calibration of these tracers. The measurements examine the influence of temperature, pressure, and residence time on tracer oxidation, which occurs without a rise in temperature or pressure inside the cell, highlighting the need for optical detection. A comparison between the three different tracers shows large differences, with diethylketone having the lowest and toluene by far the highest stability. An analysis of the sensitivity of the measurement shows that the detection limit of the oxidized tracer is well below 3% molar fraction, which is typical for LIF applications in combustion devices such as internal combustion (IC) engines. Furthermore, the effect on the LIF signal intensity is examined in an isothermal turbulent mixing study.

[1]  A. Leipertz,et al.  Acetone laser-induced fluorescence behavior for the simultaneous quantification of temperature and residual gas distribution in fired spark-ignition engines. , 2010, Applied optics.

[2]  Y. Hattori,et al.  Quantitative 2-D Fuel Distribution Measurements in an SI Engine Using Laser-Induced Fluorescence with Suitable Combination of Fluorescence Tracer and Excitation Wavelength , 1997 .

[3]  C. Westbrook,et al.  Diagnostic implications of the reactivity of fluorescence tracers , 2009 .

[4]  M. Morris,et al.  Infrared and Raman Spectroscopy , 2000 .

[5]  Ronald K. Hanson,et al.  Simultaneous Imaging of Exhaust Gas Residuals and Temperature During HCCI Combustion , 2009 .

[6]  H. Wagner,et al.  Untersuchungen zum thermischen Zerfall von Acetaldehyd und Aceton , 1976 .

[7]  Thomas Seeger,et al.  Application of 266-nm and 355-nm Nd:YAG laser radiation for the investigation of fuel-rich sooting hydrocarbon flames by raman scattering. , 2004, Applied optics.

[8]  Y. Hidaka,et al.  Shock-tube and modeling study of acetone pyrolysis and oxidation , 2000 .

[9]  Kenji Fukui,et al.  2-D Temperature Measurements of Unburned Gas Mixture in an Engine by Two-line Excitation LIF Technique , 2006 .

[10]  P. Guibert,et al.  3-Pentanone LIF at elevated temperatures and pressures: measurements and modeling , 2007 .

[11]  M. G. Zabetakis Flammability characteristics of combustible gases and vapors , 1964 .

[12]  L. Gasnot,et al.  A comprehensive chemical mechanism for the oxidation of methylethylketone in flame conditions , 2002 .

[13]  H. Curran,et al.  Oxidation of Acetone and Its Interaction with Nitric Oxide , 2010 .

[14]  C. Hinshelwood,et al.  A Homogeneous Unimolecular Reactions-The Thermal Decomposition of Acetone in the Gaseous State , 1926 .

[15]  Ronald K. Hanson,et al.  CW laser-induced fluorescence of toluene for time-resolved imaging of gaseous flows , 2010 .

[16]  Martin Hattwig,et al.  Handbook of Explosion Prevention and Protection , 2004 .

[17]  A. Dreizler,et al.  High-speed PIV and LIF imaging of temperature stratification in an internal combustion engine , 2013 .

[18]  N. Wermuth,et al.  Absorption and fluorescence data of acetone, 3-pentanone, biacetyl, and toluene at engine-specific combinations of temperature and pressure , 2005 .

[19]  M. Thurber Acetone laser-induced fluorescence for temperature and multiparameter imaging in gaseous flows , 1999 .

[20]  Jon Koch,et al.  Fuel tracer photophysics for quantitative planar laser-induced fluorescence , 2005 .

[21]  Volker Sick,et al.  Measurement of temperature, fuel concentration and equivalence ratio fields using tracer LIF in IC engine combustion , 2000 .

[22]  A. Leipertz,et al.  Simultaneous Two-Dimensional Flow Velocity and Gas Temperature Measurements by use of a Combined Particle Image Velocimetry and Filtered Rayleigh Scattering Technique. , 2001, Applied optics.

[23]  Volker Sick,et al.  Temperature and pressure dependences of the laser-induced fluorescence of gas-phase acetone and 3-pentanone , 1996 .

[24]  A. Leipertz,et al.  Quantitative vapor temperature imaging in DISI-sprays at elevated pressures and temperatures using two-line excitation laser-induced fluorescence , 2013 .

[25]  M. Bellenoue,et al.  Characterization of a two-dimensional temperature field within a rapid compression machine using a toluene planar laser-induced fluorescence imaging technique , 2009 .

[26]  Lars Zigan,et al.  Application of linear Raman spectroscopy for the determination of acetone decomposition. , 2011, Optics express.

[27]  R. Hanson,et al.  Temperature imaging with single- and dual-wavelength acetone planar laser-induced fluorescence. , 1997, Optics letters.

[28]  A. Leipertz,et al.  Laser-induced fluorescence of ketones at elevated temperatures for pressures up to 20 bars by using a 248 nm excitation laser wavelength: experiments and model improvements. , 2006, Applied optics.

[29]  C. Hinshelwood,et al.  The thermal decomposition of acetone vapour , 1935 .

[30]  M. Aldén,et al.  Measurements of picosecond laser induced fluorescence from gas phase 3-pentanone and acetone: Implications to combustion diagnostics , 1997 .

[31]  Volker Sick,et al.  Tracer-LIF diagnostics: quantitative measurement of fuel concentration, temperature and fuel/air ratio in practical combustion systems , 2005 .

[32]  Ronald K. Hanson,et al.  Predicting LIF signal strength for toluene and 3-pentanone under engine-related temperature and pressure conditions , 2004 .

[33]  Ronald K. Hanson,et al.  Acetone: a tracer for concentration measurements in gaseous flows by planar laser-induced fluorescence , 1992 .