MRI velocimetry in microchannel networks

Magnetic Resonance Imaging (MRI) velocimetry was used for the first time to quantify the interstitial 2-D velocity field of water through an engineered microchannel network constructed from poly-dimethylsiloxane (PDMS). We describe the fabrication of the multilayered PDMS network, which consists of two identical non-communicating capillary networks, each featuring 2 mm deep and 0.9 mm wide staggered channels forming a 10/spl times/8 periodic array. The logistics of perfusing the network through multiple interconnects and the velocity extraction are delineated. The effect of a priori or a posteriori methods to estimate the interstitial volume on the accuracy of the pore velocity is shown to be significant.

[1]  Daniel L Marks,et al.  Structural and functional imaging of 3D microfluidic mixers using optical coherence tomography. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[2]  Alex Groisman,et al.  A microfluidic rectifier: anisotropic flow resistance at low Reynolds numbers. , 2004, Physical review letters.

[3]  Robin H. Liu,et al.  Passive mixing in a three-dimensional serpentine microchannel , 2000, Journal of Microelectromechanical Systems.

[4]  L. Gladden,et al.  Slow flow across macroscopically rectangular fiber lattices and an open region: Visualization by magnetic resonance imaging , 2001 .

[5]  K. Moser,et al.  On the accuracy of EPI-based phase contrast velocimetry. , 2000, Magnetic resonance imaging.

[6]  K. Moser,et al.  Extraction and validation of correlation lengths from interstitial velocity fields using diffusion-weighted MRI. , 2004, Magnetic resonance imaging.

[7]  Structural and functional imaging of 3 D microfluidic mixers using optical coherence tomography , 2004 .

[8]  K. Moser,et al.  Velocity measurements of flow through a step stenosis using Magnetic Resonance Imaging , 2000 .

[9]  Howard A. Stone,et al.  Three-dimensional flows in slowly varying planar geometries , 2003, cond-mat/0306572.

[10]  Yohei K. Sato,et al.  Visualization of convective mixing in microchannel by fluorescence imaging , 2001 .

[11]  J. Georgiadis,et al.  Kinematics of the stationary helical vortex mode in Taylor–Couette–Poiseuille Flow , 2004, Journal of Fluid Mechanics.

[12]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[13]  D. Beebe,et al.  A particle image velocimetry system for microfluidics , 1998 .

[14]  John G. Georgiadis,et al.  Convection and flow in porous media. Part 1. Visualization by magnetic resonance imaging , 1997, Journal of Fluid Mechanics.

[15]  D. Beebe,et al.  Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer , 2000, Journal of Microelectromechanical Systems.

[16]  Howard A. Stone,et al.  ENGINEERING FLOWS IN SMALL DEVICES , 2004 .

[17]  Rustem F Ismagilov,et al.  Integrated microfluidic systems. , 2003, Angewandte Chemie.

[18]  D. Beebe,et al.  Physics and applications of microfluidics in biology. , 2002, Annual review of biomedical engineering.

[19]  D. Beebe,et al.  A valved responsive hydrogel microdispensing device with integrated pressure source , 2004, Journal of Microelectromechanical Systems.