Analysis of Thermal Comfort in a Residential Room with Multiple Vents: A Case Study by Numerical Simulation Technique

Thermal comfort is very essential for the occupants in the residential building without air-conditioning system in the hot and arid climatic regions. In this study, the thermal comfort prevailed inside the room with window openings at their adjacent walls was analyzed under various wind directions by computational fluid dynamic technique. The CFD simulation was validated with the experimental results obtained from wind tunnel test rig and network model and found that it is having a good agreement. The room with single window opening at the adjacent walls was investigated under various wind directions and based on their prevailed uncomforted zones, the window opening at the windward side wall was splited in to multiple vents as double and triple vent system without changing window opening area. From this study, it was identified that the triple vent system reduces the indoor temperature and predicted mean vote by 0.3 and provides improved uniform thermal comfort.

[1]  Paramasivam Ravikumar,et al.  Analysis of thermal comfort in an office room by varying the dimensions of the windows on adjacent walls using CFD: A case study based on numerical simulation , 2009 .

[2]  D. Prakash,et al.  Analysis of thermal comfort in a residential room with insect proof screen: A case study by numerical simulation methods , 2011 .

[3]  J. Busch A tale of two populations: thermal comfort in air-conditioned and naturally ventilated offices in Thailand , 1992 .

[4]  Bje Bert Blocken,et al.  CFD simulation of cross-ventilation for a generic isolated building : impact of computational parameters , 2012 .

[5]  Mohamed B. Gadi,et al.  A comparison between CFD and Network models for predicting wind-driven ventilation in buildings , 2007 .

[6]  John D. Spengler,et al.  Relationships Between Ventilation and Indoor Air Quality: A Review , 1996 .

[7]  Dominique Marchio,et al.  Full scale experimental study of single-sided ventilation: Analysis of stack and wind effects , 2011 .

[8]  Weeratunge Malalasekera,et al.  An introduction to computational fluid dynamics - the finite volume method , 2007 .

[9]  G. Evola,et al.  Computational analysis of wind driven natural ventilation in buildings , 2006 .

[10]  Xiong Shen,et al.  Comparison of different methods for estimating ventilation rates through wind driven ventilated buildings , 2012 .

[11]  Per Heiselberg,et al.  Single-sided natural ventilation driven by wind pressure and temperature difference , 2008 .

[12]  H. Awbi Ventilation of buildings , 1873 .

[13]  K. Visagavel,et al.  Analysis of single side ventilated and cross ventilated rooms by varying the width of the window opening using CFD , 2009 .

[14]  Shinsuke Kato,et al.  Wind-induced ventilation performances and airflow characteristics in an areaway-attached basement wi , 2011 .