Precision charge control for isolated free-falling test masses: LISA pathfinder results

The LISA Pathfinder charge management device was responsible for neutralizing the cosmic-ray-induced electric charge that inevitably accumulated on the free-falling test masses at the heart of the experiment. We present measurements made on ground and in flight that quantify the performance of this contactless discharge system which was based on photoemission under UV illumination. In addition, a two-part simulation is described that was developed alongside the hardware. Modeling of the absorbed UV light within the Pathfinder sensor was carried out with the Geant4 software toolkit and a separate Matlab charge transfer model calculated the net photocurrent between the test masses and surrounding housing in the presence of AC and DC electric fields. We confront the results of these models with observations and draw conclusions for the design of discharge systems for future experiments like LISA that will also employ free-falling test masses.

[1]  A. Petiteau,et al.  Characteristics and Energy Dependence of Recurrent Galactic Cosmic-Ray Flux Depressions and of a Forbush Decrease with LISA Pathfinder , 2018, 1802.09374.

[2]  J. P. López-Zaragoza,et al.  Beyond the Required LISA Free-Fall Performance: New LISA Pathfinder Results down to 20  μHz. , 2018, Physical review letters.

[3]  Salvatore J. Vitale,et al.  Measuring the galactic cosmic ray flux with the LISA Pathfinder radiation monitor , 2017, 1711.07427.

[4]  J. Baird,et al.  Lifetime testing UV LEDs for use in the LISA charge management system , 2017, 1705.06256.

[5]  J. P. López-Zaragoza,et al.  Charge-Induced Force Noise on Free-Falling Test Masses: Results from LISA Pathfinder. , 2017, Physical review letters.

[6]  J. P. López-Zaragoza,et al.  Sub-Femto-g Free Fall for Space-Based Gravitational Wave Observatories: LISA Pathfinder Results. , 2016, Physical review letters.

[7]  D. Hollington,et al.  Characterising and testing deep UV LEDs for use in space applications , 2015, 1508.00812.

[8]  M. A. Cortés-Giraldo,et al.  Recent developments in GEANT4 , 2015 .

[9]  Walter Fichter,et al.  Modeling and performance of contact-free discharge systems for space inertial sensors , 2012, IEEE Transactions on Aerospace and Electronic Systems.

[10]  K. Perez Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment , 2014 .

[11]  Gerald Hechenblaikner,et al.  Energy distribution and quantum yield for photoemission from air-contaminated gold surfaces under ultraviolet illumination close to the threshold , 2012, 1206.1347.

[12]  L. G. Boté,et al.  Laser Interferometer Space Antenna , 2012 .

[13]  W. Weber,et al.  Interaction between stray electrostatic fields and a charged free-falling test mass. , 2012, Physical review letters.

[14]  R. Rummel,et al.  GOCE gravitational gradiometry , 2011 .

[15]  Walter Fichter,et al.  The LISA Pathfinder interferometry—hardware and system testing , 2011 .

[16]  Daniel Hollington,et al.  The charge management system for LISA and LISA Pathfinder , 2011 .

[17]  G. Ciani,et al.  Direct force measurements for testing the LISA Pathfinder gravitational reference sensor , 2009 .

[18]  S. Nannarone,et al.  Inertial sensor surface properties for LISA Pathfinder and their effect on test mass discharging , 2009 .

[19]  Francesco Biral,et al.  LISA Pathfinder test mass injection in geodesic motion: status of the on-ground testing , 2009 .

[20]  R. Byer,et al.  UV LED operation lifetime and radiation hardness qualification for space flights , 2009 .

[21]  L. Carbone,et al.  Possibilities for measurement and compensation of stray DC electric fields acting on drag-free test masses , 2003, gr-qc/0309067.

[22]  W. J. Weber,et al.  Testing of the UV discharge system for LISA Pathfinder , 2006 .

[23]  Robert L. Byer,et al.  LED deep UV source for charge management of gravitational reference sensors , 2006 .

[24]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[25]  Peter Wass,et al.  Test-mass charging simulations for the LISA Pathfinder mission , 2005 .

[26]  T. Sumner,et al.  Evaluation of disturbances due to test mass charging for LISA , 2005 .

[27]  T. Sumner,et al.  Detailed calculation of test-mass charging in the LISA mission , 2004, astro-ph/0405522.

[28]  M. Watkins,et al.  The gravity recovery and climate experiment: Mission overview and early results , 2004 .

[29]  Daniele Bortoluzzi,et al.  Position sensors for flight testing of LISA drag-free control , 2003, SPIE Astronomical Telescopes + Instrumentation.

[30]  A. Dell'Acqua,et al.  Geant4 - A simulation toolkit , 2003 .

[31]  C. Reigber,et al.  CHAMP mission status , 2002 .

[32]  P. Touboul,et al.  The MICROSCOPE space mission , 2001 .

[33]  T. Sumner,et al.  Electrostatic charging of the LISA proof masses , 1997 .

[34]  Clive C. Speake,et al.  Forces and force gradients due to patch fields and contact-potential differences , 1996 .

[35]  P. Platzman,et al.  Feasibility study of photocathode electron projection lithography , 1995 .

[36]  Saps Buchman,et al.  Charge measurement and control for the Gravity Probe B gyroscopes , 1995 .

[37]  W. M. Haynes CRC Handbook of Chemistry and Physics , 1990 .

[38]  D. Lynch,et al.  Handbook of Optical Constants of Solids , 1985 .

[39]  R. W. Christy,et al.  Optical Constants of the Noble Metals , 1972 .

[40]  K. Torrance,et al.  Theory for off-specular reflection from roughened surfaces , 1967 .

[41]  E. Huber THE EFFECT OF MERCURY CONTAMINATION ON THE WORK FUNCTION OF GOLD , 1966 .