The design and application of an inexpensive pressure monitoring system for shallow water level measurement, tensiometry and piezometry

Summary The measurement of water level or pressure is often a key requirement in the study of hydrogeological, hydrological and soil science processes. Modern microelectronics can provide a range of solutions for the automated monitoring of water levels in boreholes, rivers as well as more specialised applications such as tensiometry. The advantages of stand-alone monitoring systems when compared to manual measurement approaches are well understood, especially when the point of measurement is remote or the frequency of perturbation is rapid. For this reason the combination of a pressure transducer and logging system within a single package has been widely adopted in commercially available systems. However, although the price of these devices continues to fall, they may still represent a significant cost for researchers on limited budgets. We therefore present a design for a simple, inexpensive (∼£30) but versatile pressure monitoring system which can interface to low-cost (£50–£70) data-loggers. We demonstrate how the design may be adapted for a range of field applications which include: river level measurements, tensiometers, permeameters and in situ river-bed piezometers. The performance of the system is assessed and for each application the specific design and examples of resulting data are described.

[1]  Martin Thalheimer,et al.  Tensiometer modification for diminishing errors due to the fluctuating inner water column , 2003 .

[2]  Paul Horowitz,et al.  The Art of Electronics , 1980 .

[3]  M. Cuthbert Hydraulic processes controlling recharge through glacial drift , 2006 .

[4]  M. Rivett,et al.  Cost-effective mini drive-point piezometers and multilevel samplers for monitoring the hyporheic zone , 2008, Quarterly Journal of Engineering Geology and Hydrogeology.

[5]  Chris Soulsby,et al.  High‐frequency logging technologies reveal state‐dependent hyporheic process dynamics: implications for hydroecological studies , 2006 .

[6]  Steven P Loheide,et al.  Noise in pressure transducer readings produced by variations in solar radiation. , 2004, Ground water.

[7]  R. D. Barker,et al.  The use of electrical resistivity tomography in deriving local-scale models of recharge through superficial deposits , 2009 .

[8]  J. Dowd,et al.  Use of inexpensive pressure transducers for measuring water levels in wells , 1997, Wetlands Ecology and Management.

[9]  P. A. Ellis The impact of urban groundwater upon surface water quality : Birmingham - River Tame study, UK , 2003 .

[10]  Gq,et al.  Groundwater Quality: Natural and Enhanced Restoration of Groundwater Pollution , 2002 .

[11]  C. Maksimovic,et al.  Estimation of groundwater-contaminant fluxes to urban rivers. , 2004 .

[12]  M. Rivett,et al.  Assessing the impact of VOC-contaminated groundwater on surface water at the city scale. , 2007, Journal of contaminant hydrology.

[13]  M. J. Hvorslev Time lag and soil permeability in ground-water observations , 1951 .

[14]  P. Wierenga,et al.  A Pressure Transducer for Field Tensiometers1 , 1983 .

[15]  Adunias dos Santos Teixeira,et al.  Desenvolvimento e calibração de um tensiômetro eletrônico de leitura automática , 2005 .

[16]  Timothy C. Riley,et al.  Monitoring soil moisture and water table height with a low-cost data logger , 2006, Comput. Geosci..