Effect of the static magnetic field of the MR-scanner on ERPs: Evaluation of visual, cognitive and motor potentials

OBJECTIVE This work investigates the influence of the static magnetic field of the MR-scanner on ERPs extracted from simultaneous EEG-fMRI recordings. The quality of the ERPs after BallistoCardioGraphic (BCG) artifact removal, as well as the reproducibility of the waveforms in different environments is investigated. METHODS We consider a Detection, a Go-Nogo and a Motor task, eliciting peaks that differ in amplitude, latency and scalp topography, repeated in two situations: outside the scanner room (0T) and inside the MR-scanner but without gradients (3T). The BCG artifact is removed by means of three techniques: the Average Artifact Subtraction (AAS) method, the Optimal Basis Set (OBS) method and the Canonical Correlation Analysis (CCA) approach. RESULTS The performance of the three methods depends on the amount of averaged trials. Moreover, differences are found on both amplitude and latency of ERP components recorded in two environments (0T vs 3T). CONCLUSIONS We showed that, while ERPs can be extracted from simultaneous EEG-fMRI data at 3T, the static magnetic field might affect the physiological processes under investigation. SIGNIFICANCE The reproducibility of the ERPs in different recording environments (0T vs 3T) is a relevant issue that deserves further investigation to clarify the equivalence of cognitive processes in both behavioral and imaging studies.

[1]  Jean Gotman,et al.  EEG‐Correlated Functional MRI: Recent Methodologic Progress and Current Issues , 2002 .

[2]  Robert Schmitt,et al.  Integration of fMRI and simultaneous EEG: towards a comprehensive understanding of localization and time-course of brain activity in target detection , 2004, NeuroImage.

[3]  J. Gotman,et al.  Quality of EEG in simultaneous EEG-fMRI for epilepsy , 2003, Clinical Neurophysiology.

[4]  S. Debener,et al.  Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[5]  D. Stewart,et al.  A general canonical correlation index. , 1968, Psychological bulletin.

[6]  Wolfgang Prinz,et al.  Equivalence of cognitive processes in brain imaging and behavioral studies: evidence from task switching , 2003, NeuroImage.

[7]  Bettina Sorger,et al.  Novelty and target processing during an auditory novelty oddball: A simultaneous event-related potential and functional magnetic resonance imaging study , 2008, NeuroImage.

[8]  J T Mordkoff,et al.  Detecting the onset of the lateralized readiness potential: a comparison of available methods and procedures. , 2000, Psychophysiology.

[9]  Gene H. Golub,et al.  Matrix computations , 1983 .

[10]  Andrzej Cichocki,et al.  Removal of ballistocardiogram artifacts from simultaneously recorded EEG and fMRI data using independent component analysis , 2006, IEEE Transactions on Biomedical Engineering.

[11]  Peter Kirsch,et al.  Acquisition of typical EEG waveforms during fMRI: SSVEP, LRP, and frontal theta , 2005, NeuroImage.

[12]  Arnaud Delorme,et al.  EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis , 2004, Journal of Neuroscience Methods.

[13]  Kristina M. Ropella,et al.  Ballistocardiogram artifact reduction in the simultaneous acquisition of auditory ERPS and fMRI , 2004, NeuroImage.

[14]  Gian Luca Romani,et al.  Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis , 2007, NeuroImage.

[15]  Sabine Van Huffel,et al.  Removal of BCG artifacts from EEG recordings inside the MR scanner: A comparison of methodological and validation-related aspects , 2010, NeuroImage.

[16]  Bettina Sorger,et al.  Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: Removal of the ballistocardiogram artefact , 2007, NeuroImage.

[17]  S. Hillyard,et al.  Cortical sources of the early components of the visual evoked potential , 2002, Human brain mapping.

[18]  M. Verhoye,et al.  Reduction of ECG and gradient related artifacts in simultaneously recorded human EEG/MRI data. , 2000, Magnetic resonance imaging.

[19]  A. Kok Effects of degradation of visual stimuli on components of the event-related potential (ERP) in go/nogo reaction tasks , 1986, Biological Psychology.

[20]  Frédéric Grouiller,et al.  A comparative study of different artefact removal algorithms for EEG signals acquired during functional MRI , 2007, NeuroImage.

[21]  Manuel Abbafati,et al.  An independent component analysis-based approach on ballistocardiogram artifact removing. , 2006, Magnetic resonance imaging.

[22]  Arno Villringer,et al.  Visual evoked potentials recovered from fMRI scan periods , 2005, Human brain mapping.

[23]  F Kruggel,et al.  Recording of the event‐related potentials during functional MRI at 3.0 Tesla field strength , 2000, Magnetic resonance in medicine.

[24]  H. Shibasaki Human brain mapping: Hemodynamic response and electrophysiology , 2008, Clinical Neurophysiology.

[25]  M. Patterson,et al.  The use of magnetic field effects on photosensitizer luminescence as a novel probe for optical monitoring of oxygen in photodynamic therapy , 2009, Physics in medicine and biology.

[26]  Alberto Inuggi,et al.  Visual evoked potentials may be recorded simultaneously with fMRI scanning: A validation study , 2005, Human brain mapping.

[27]  Paul Sajda,et al.  Removal of BCG Artifacts Using a Non-Kirchhoffian Overcomplete Representation , 2009, IEEE Transactions on Biomedical Engineering.

[28]  Louis Lemieux,et al.  EEG/Functional MRI in Epilepsy: The Queen Square Experience , 2004, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[29]  Martin Eimer,et al.  The lateralized readiness potential as an on-line measure of central response activation processes , 1998 .

[30]  Rami K. Niazy,et al.  Removal of FMRI environment artifacts from EEG data using optimal basis sets , 2005, NeuroImage.

[31]  Wim Van Paesschen,et al.  Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram , 2006, IEEE Transactions on Biomedical Engineering.

[32]  Jordan Grafman,et al.  Handbook of Neuropsychology , 1991 .

[33]  Xianggui Qu,et al.  Multivariate Data Analysis , 2007, Technometrics.

[34]  Mark S. Cohen,et al.  Acquiring simultaneous EEG and functional MRI , 2000, Clinical Neurophysiology.

[35]  J. Ford,et al.  ERPs to response production and inhibition. , 1985, Electroencephalography and clinical neurophysiology.

[36]  Gene H. Golub,et al.  Matrix computations (3rd ed.) , 1996 .

[37]  S. Debener,et al.  Simultaneous recording of EEG and BOLD responses: a historical perspective. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[38]  Aureliu Lavric,et al.  ERP differences with vs. without concurrent fMRI. , 2006, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[39]  Johan Wagemans,et al.  Ballistocardiogram artifacts in simultaneous EEG- fMRI acquisitions , 2007 .

[40]  H. Hotelling Relations Between Two Sets of Variates , 1936 .

[41]  Hans Hallez,et al.  Removal of the ballistocardiographic artifact from EEG-fMRI data: a canonical correlation approach. , 2009, Physics in medicine and biology.

[42]  Louis Lemieux,et al.  Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction , 1998, NeuroImage.

[43]  Margot J. Taylor,et al.  Guidelines for using human event-related potentials to study cognition: recording standards and publication criteria. , 2000, Psychophysiology.

[44]  Talma Hendler,et al.  The validity of the face-selective ERP N170 component during simultaneous recording with functional MRI , 2008, NeuroImage.

[45]  Christophe Phillips,et al.  Rejection of pulse related artefact (PRA) from continuous electroencephalographic (EEG) time series recorded during functional magnetic resonance imaging (fMRI) using constraint independent component analysis (cICA) , 2009, NeuroImage.

[46]  G. Srivastava,et al.  ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner , 2005, NeuroImage.