Intraocular Lens Formula Comparison of Flanged Intrascleral Intraocular Lens Fixation with Double Needle Technique

Purpose To analyze visual outcomes and accuracy of intraocular lens (IOL) calculation formulas in predicting postoperative outcomes in patients undergoing flanged intrascleral IOL fixation. Design Case Series. Subjects Twenty-three patients who had undergone secondary IOL placement using flanged intrascleral fixation technique. Methods Retrospective chart review. Main Outcome Measures Corrected distance visual acuity (CDVA) and postoperative spherical equivalent based on manifest refraction. Results Visual acuity improved from 20/577 to 20/58. Overall, the actual refraction was 0.06 D more myopic than predicted. Holladay 2, Sanders Retzlaff Kraff/Theoretical (SRK/T) and Barrett Universal II resulted in mild myopic surprise (−0.55, −0.18 and −0.20 D). Haigis and Hill-RBF (Radial Basis Function) resulted in mild hyperopic surprise (+0.28 and +0.28 D). Hoffer Q and Holladay 1 were the most accurate (−0.02D and −0.08 D). Conclusion Flanged intrascleral IOL fixation improved vision even in patients with other posterior segment pathologies. The effective lens positioning is likely similar to in-the-bag positioning. Hoffer Q and Holladay 1 formulas with in-the-bag calculations were the most accurate.

[1]  Mitchell P. Weikert,et al.  Accuracy of intraocular lens calculation formulas for flanged intrascleral intraocular lens fixation with double-needle technique , 2020, Journal of cataract and refractive surgery.

[2]  S. Koenig,et al.  Clinical Outcomes and Lens Constant Optimization of the Zeiss CT Lucia 602 Lens Using a Modified Yamane Technique , 2020, Clinical ophthalmology.

[3]  Jack X. Kane,et al.  Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service. , 2020, Journal of cataract and refractive surgery.

[4]  A. Abazari,et al.  Refractive outcomes of phacoemulsification after pars plana vitrectomy using traditional and new intraocular lens calculation formulas. , 2019, Journal of cataract and refractive surgery.

[5]  A. Shrivastava,et al.  Precision of intraocular lens power prediction in eyes shorter than 22 mm: An analysis of 6 formulas. , 2018, Journal of cataract and refractive surgery.

[6]  R. Fogla,et al.  Comparison of Two Modified Sutureless Techniques of Scleral Fixation of Intraocular Lens. , 2018, Ophthalmic surgery, lasers & imaging retina.

[7]  M. K. Walsh,et al.  27-GAUGE SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENSES WITH HAPTIC FLANGING: Short-Term Clinical Outcomes and a Disinsertion Force Study. , 2018, Retina.

[8]  D. Koch,et al.  Accuracy of 8 intraocular lens calculation formulas in relation to anterior chamber depth in patients with normal axial lengths. , 2018, Journal of cataract and refractive surgery.

[9]  J. Holladay,et al.  Accuracy of Intraocular Lens Calculation Formulas. , 2017, Ophthalmology.

[10]  Shin Yamane,et al.  Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique. , 2017, Ophthalmology.

[11]  Mitchell P. Weikert,et al.  Secondary intraocular lens implantation: Complication rates, visual acuity, and refractive outcomes. , 2017, Journal of cataract and refractive surgery.

[12]  Jack X. Kane,et al.  Intraocular lens power formula accuracy: Comparison of 7 formulas , 2016, Journal of cataract and refractive surgery.

[13]  S. Sengupta,et al.  Comparison of sutured versus sutureless scleral‐fixated intraocular lenses , 2016, Journal of cataract and refractive surgery.

[14]  B. Monson,et al.  Transscleral fixation of a foldable posterior chamber intraocular lens , 2015, Journal of cataract and refractive surgery.

[15]  S. Dorairaj,et al.  Comparative evaluation of suture-assisted and fibrin glue-assisted scleral fixated intraocular lens implantation. , 2012, Journal of refractive surgery.

[16]  S. Binder,et al.  Accuracy of preoperative biometry in vitrectomy combined with cataract surgery for patients with epiretinal membranes and macular holes: Results of a prospective controlled clinical trial , 2008, Journal of cataract and refractive surgery.

[17]  Soosan Jacob,et al.  Fibrin glue–assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules , 2008, Journal of cataract and refractive surgery.

[18]  J. Seland,et al.  Implantation of scleral‐fixated posterior chamber intraocular lenses in adults , 2008, Acta ophthalmologica.

[19]  Sverker Norrby,et al.  Sources of error in intraocular lens power calculation , 2008, Journal of cataract and refractive surgery.

[20]  A. Marinho,et al.  Scleral fixation in eyes with loss of capsule or zonule support , 2007, Journal of cataract and refractive surgery.

[21]  J. Jeoung,et al.  Factors influencing refractive outcomes after combined phacoemulsification and pars plana vitrectomy: Results of a prospective study , 2007, Journal of cataract and refractive surgery.

[22]  Illés Kovács,et al.  Intraocular lens power calculation for combined cataract surgery, vitrectomy and peeling of epiretinal membranes for macular oedema. , 2006, Acta ophthalmologica Scandinavica.

[23]  M. Araie,et al.  10-year follow-up study of secondary transscleral ciliary sulcus fixated posterior chamber intraocular lenses. , 2003, American journal of ophthalmology.

[24]  M. Nakazawa,et al.  Postoperative refractive error after simultaneous vitrectomy and cataract surgery. , 2000, Ophthalmic surgery and lasers.

[25]  H. Hayashi,et al.  Intraocular lens tilt and decentration, anterior chamber depth, and refractive error after trans-scleral suture fixation surgery. , 1999, Ophthalmology.

[26]  N. Ogino,et al.  Change in postoperative refractive error when vitrectomy is added to intraocular lens implantation , 1997, Journal of cataract and refractive surgery.

[27]  H. Mittelviefhaus,et al.  Transscleral suture fixation of posterior-chamber lenses after cataract extraction associated with vitreous loss. , 1995, German journal of ophthalmology.

[28]  J. Gottsch,et al.  Posterior chamber intraocular lens implantation in the absence of capsular support. , 1989, Archives of ophthalmology.