An attenuation correction technique to correct for neutron and gamma attenuation in the reconstructed image of a neutron stimulated emission computed tomography (NSECT) system

Neutron spectroscopy is being developed as a tomographic tool to measure trace element concentration in the body at molecular levels. We are developing a neutron stimulated emission computed tomography (NSECT) system using inelastic scattering of neutrons by target nuclei, to identify elements and their concentration in tissue. An incoming neutron scatters inelastically with an atomic nucleus, which emits a gamma photon of specific energy. This energy, which is detected by an energy-sensitive Gamma detector, is characteristic of the scattering nucleus. The neutron beam and gamma photons undergo considerable attenuation while passing through the body, causing a reduction in detected counts leading to inaccurate reconstruction. We describe a technique to correct for this attenuation as follows. The scanning geometry used for data acquisition is simulated. The lengths of attenuating material lying in the path of the neutron beam are calculated. Neutron attenuation is determined along this path, using attenuation coefficients for each element. Gamma attenuation is calculated similarly for the path between the point of gamma origin and the detector. A transmission profile is then determined for each projection, using the product of the neutron and gamma attenuations for every point along the projection. The inverse of the integral of this profile yields a correction factor. The experimental data is multiplied by the correction factors to yield attenuation corrected projections. After correction, the projection data is seen to represent the known elemental distribution more accurately. This correction technique improves the consistency of the projections, and leads to the improved accuracy in reconstructed NSECT images.

[1]  L. G. Hiltz,et al.  Attenuation correction for three-dimensional PET using uncollimated flood-source transmission measurements. , 1994, Physics in medicine and biology.

[2]  S L Rizk,et al.  Comparison between concentrations of trace elements in normal and neoplastic human breast tissue. , 1984, Cancer research.

[3]  James E. Bowsher,et al.  Neutron stimulated emission computed tomography of stable isotopes , 2004, SPIE Medical Imaging.

[4]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[5]  D. Rubin,et al.  Maximum likelihood from incomplete data via the EM - algorithm plus discussions on the paper , 1977 .

[6]  J.A. Fessler Segmented attenuation correction for PET , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[7]  L. Baum,et al.  A Maximization Technique Occurring in the Statistical Analysis of Probabilistic Functions of Markov Chains , 1970 .

[8]  R. W. Fink,et al.  Trace elements in noraml and malignant human breast tissue. , 1974, Surgery.

[9]  L. Looi,et al.  Elevated trace element concentrations in malignant breast tissues. , 1997, The British journal of radiology.

[10]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[11]  D. Bradley,et al.  Concentrations of Fe, Cu and Zn in breast tissue: a synchrotron XRF study. , 2002, Physics in medicine and biology.

[12]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[13]  M. Woodbury A missing information principle: theory and applications , 1972 .

[14]  H. Mussalo-Rauhamaa,et al.  Cu, Zn, Se and Mg concentrations in breast fat of Finnish breast cancer patients and healthy controls , 1993 .

[15]  V. Singh,et al.  An elemental correlation study in cancerous and normal breast tissue with successive clinical stages by neutron activation analysis , 1994, Biological Trace Element Research.

[16]  R. R. Hocking,et al.  The analysis of incomplete data. , 1971 .