Effectiveness assessment of signal processing in the presence of smear

Moving imagery from a static scene was recorded with an uncooled thermal imager at nine different angular velocities ranging from 0 (static) to 1 pixel∕frame (3.75 deg ∕s) using a tilted rotating mirror. The scene contained a thermal acuity test chart with triangular test patterns based on the triangle orientation discrimination (TOD) test method. The imagery was processed with different types of image enhancement: dynamic super-resolution (DSR), local adaptive contrast enhancement (LACE), and combinations. DSR shows a significant performance improvement at low velocities, a moderate improvement at medium velocities where smear becomes apparent, and no benefit at high speed. Performance with LACE is close to optimized gain and level setting by hand. Static performance and dynamic performance at 0.57 pixel/frame containing significant smear were compared with earlier published identification performance data for two-hand held systems collected under a variety of signal processing conditions. It shows that the ratio M75 between the 75% correct threshold size for the two-hand held objects and the TOD triangle is preserved under all conditions measured. Thus, TA range prediction based on the TOD is robust against a complex combination of conditions, including motion, smear, and the types of image enhancement applied. © 2012 Society of Photo-Optical Instrumentation Engineers (SPIE).

[1]  Klamer Schutte,et al.  Signal conditioning algorithms for enhanced tactical sensor imagery , 2003, SPIE Defense + Commercial Sensing.

[2]  Piet Bijl Visual image quality assessment with sensor motion: effect of recording and presentation velocity. , 2010, Applied optics.

[3]  Piet Bijl,et al.  Target acquisition performance: effects of target aspect angle, dynamic imaging, and signal processing , 2008, SPIE Defense + Commercial Sensing.

[4]  Jim Thomas,et al.  Super-resolution for flash ladar imagery. , 2010, Applied optics.

[5]  S. Susan Young,et al.  Superresolution performance for undersampled imagers , 2004, SPIE Defense + Commercial Sensing.

[6]  Piet Bijl,et al.  T-CAT: a new thermal camera acuity tester , 2000, Defense, Security, and Sensing.

[7]  Patrick O'Shea,et al.  IR system field performance with superresolution , 2007, SPIE Defense + Commercial Sensing.

[8]  Klamer Schutte,et al.  Applicability of TOD, MTDP, MRT and DMRT for dynamic image enhancement techniques , 2006, SPIE Defense + Commercial Sensing.

[9]  Piet Bijl,et al.  Triangle orientation discrimination: the alternative to minimum resolvable temperature difference and minimum resolvable contrast , 1998 .

[10]  W. A. Wagenaar Note on the construction of digram-balanced Latin squares. , 1969 .

[11]  Piet Bijl,et al.  Guidelines for accurate TOD measurement , 1999, Defense, Security, and Sensing.

[12]  Ronald G. Driggers,et al.  Current infrared target acquisition approach for military sensor design and wargaming , 2006, SPIE Defense + Commercial Sensing.

[13]  Ronald G Driggers,et al.  Target-acquisition performance in undersampled infrared imagers: static imagery to motion video. , 2005, Applied optics.

[14]  S. Susan Young,et al.  Superresolution performance for undersampled imagers , 2005 .

[15]  Piet Bijl,et al.  NVThermIP vs TOD: matching the target acquisition range criteria , 2007, SPIE Defense + Commercial Sensing.