Non-invasive urinary bladder volume estimation with artefact-suppressed bio-impedance measurements

Urine output is a vital parameter to gauge kidney health. Current monitoring methods include manually written records, invasive urinary catheterization or ultrasound measurements performed by highly skilled personnel. Catheterization bears high risks of infection while intermittent ultrasound measures and manual recording are time consuming and might miss early signs of kidney malfunction. Bioimpedance (BI) measurements may serve as a non-invasive alternative for measuring urine volume in vivo. However, limited robustness have prevented its clinical translation. Here, a deep learning-based algorithm is presented that processes the local BI of the lower abdomen and suppresses artefacts to measure the bladder volume quantitatively, non-invasively and without the continuous need for additional personnel. A tetrapolar BI wearable system called ANUVIS was used to collect continuous bladder volume data from three healthy subjects to demonstrate feasibility of operation, while clinical gold standards of urodynamic (n=6) and uroflowmetry tests (n=8) provided the ground truth. Optimized location for electrode placement and a model for the change in BI with changing bladder volume is deduced. The average error for full bladder volume estimation and for residual volume estimation was -29 +/-87.6 ml, thus, comparable to commercial portable ultrasound devices (Bland Altman analysis showed a bias of -5.2 ml with LoA between 119.7 ml to -130.1 ml), while providing the additional benefit of hands-free, non-invasive, and continuous bladder volume estimation. The combination of the wearable BI sensor node and the presented algorithm provides an attractive alternative to current standard of care with potential benefits in providing insights into kidney function.

[1]  M. Folke,et al.  State of the Art of Non-Invasive Technologies for Bladder Monitoring: A Scoping Review , 2023, Sensors.

[2]  Kanika S. Dheman,et al.  Towards Artefact-Free Bio-Impedance Measurements: Evaluation, Identification and Suppression of Artefacts at Multiple Frequencies , 2022, IEEE Sensors Journal.

[3]  Kyoungwoo Lee,et al.  Continuous body impedance measurement to detect bladder volume changes during urodynamic study: A prospective study in pediatric patients , 2020, Neurourology and urodynamics.

[4]  Michele Magno,et al.  Wireless, Artefact Aware Impedance Sensor Node for Continuous Bio-Impedance Monitoring , 2020, IEEE Transactions on Biomedical Circuits and Systems.

[5]  Kyung Youn Kim,et al.  A deep neural network for estimating the bladder boundary using electrical impedance tomography , 2020, Physiological measurement.

[6]  Bruno M. G. Rosa,et al.  Bladder Volume Monitoring Using Electrical Impedance Tomography With Simultaneous Multi-Tone Tissue Stimulation and DFT-Based Impedance Calculation Inside an FPGA , 2020, IEEE Transactions on Biomedical Circuits and Systems.

[7]  H. Sax,et al.  Impact of an evidence-based intervention on urinary catheter utilization, associated process indicators, and infectious and non-infectious outcomes. , 2020, The Journal of hospital infection.

[8]  T. Smieszek,et al.  Epidemiology and health-economic burden of urinary catheter-associated infection in English NHS hospitals: a probabilistic modelling study. , 2019, The Journal of hospital infection.

[9]  Jinwu Gao,et al.  Analysis of measurement electrode location in bladder urine monitoring using electrical impedance , 2019, Biomedical engineering online.

[10]  S. Leonhardt,et al.  Evaluation of electrical impedance tomography for determination of urinary bladder volume: comparison with standard ultrasound methods in healthy volunteers , 2018, Biomedical engineering online.

[11]  Monèm Jemni,et al.  Bioelectrical impedance vector analysis (BIVA) in sport and exercise: Systematic review and future perspectives , 2018, PloS one.

[12]  Marilyn Schallom,et al.  Discrepancies in measuring bladder volumes with bedside ultrasound and bladder scanning in the intensive care unit: A pilot study , 2018, Journal of the Intensive Care Society.

[13]  Brian McGinley,et al.  Supervised Learning Classifiers for Electrical Impedance-based Bladder State Detection , 2018, Scientific Reports.

[14]  C. Kalkman,et al.  Non-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting , 2018, Journal of Clinical Monitoring and Computing.

[15]  M. van Meurs,et al.  Incidence, timing and outcome of AKI in critically ill patients varies with the definition used and the addition of urine output criteria , 2017, BMC Nephrology.

[16]  P. Moalli,et al.  Role of pelvic floor in lower urinary tract function , 2016, Autonomic Neuroscience.

[17]  Milos R Popovic,et al.  A Phase-Based Electrical Plethysmography Approach to Bladder Volume Measurement , 2016, Annals of Biomedical Engineering.

[18]  E. Macedo Urine Output Assessment as a Clinical Quality Measure , 2015, Nephron.

[19]  Fatimah Ibrahim,et al.  The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status Monitoring and Diagnosis of Diseases , 2014, Sensors.

[20]  Steffen Leonhardt,et al.  Electric impedance tomography for monitoring volume and size of the urinary bladder , 2011, Biomedizinische Technik. Biomedical engineering.

[21]  C. Umscheid,et al.  Estimating the Proportion of Healthcare-Associated Infections That Are Reasonably Preventable and the Related Mortality and Costs , 2011, Infection Control & Hospital Epidemiology.

[22]  Craig A. Umscheid,et al.  Guideline for Prevention of Catheter-Associated Urinary Tract Infections 2009 , 2010, Infection Control & Hospital Epidemiology.

[23]  C. Parikh,et al.  Biomarkers of acute kidney injury: can we replace serum creatinine? , 2007, Clinical nephrology.

[24]  D. Cardo,et al.  Estimating Health Care-Associated Infections and Deaths in U.S. Hospitals, 2002 , 2007, Public health reports.

[25]  C. O. Kim,et al.  Outbreaks of Serratia marcescens bacteriuria in a neurosurgical intensive care unit of a tertiary care teaching hospital: a clinical, epidemiologic, and laboratory perspective. , 2005, American journal of infection control.

[26]  M. Elia,et al.  Bioelectrical impedance analysis-part II: utilization in clinical practice. , 2004, Clinical nutrition.

[27]  M. Elia,et al.  Bioelectrical impedance analysis--part I: review of principles and methods. , 2004, Clinical nutrition.

[28]  M. T. Rise,et al.  An Ultrasonic Bladder-Volume Sensor , 1979, IEEE Transactions on Biomedical Engineering.

[29]  A. Menciassi,et al.  Bladder Monitoring Systems: State of the Art and Future Perspectives , 2022, IEEE Access.

[30]  L. Bih,et al.  The accuracy of ultrasonic estimation of bladder volume: a comparison of portable and stationary equipment. , 2004, Archives of physical medicine and rehabilitation.

[31]  J. Abbey,et al.  Electrical impedance measurement of urinary bladder fullness. , 1983, The Journal of microwave power.