A distributed current stimulator ASIC for high density neural stimulation

This paper presents a novel distributed neural stimulator scheme. Instead of a single stimulator ASIC in the package, multiple ASICs are embedded at each electrode site for stimulation with a high density electrode array. This distributed architecture enables the simplification of wiring between electrodes and stimulator ASIC that otherwise could become too complex as the number of electrode increases. The individual ASIC chip is designed to have a shared data bus that independently controls multiple stimulating channels. Therefore, the number of metal lines is determined by the distributed ASICs, not by the channel number. The function of current steering is also implemented within each ASIC in order to increase the effective number of channels via pseudo channel stimulation. Therefore, the chip area can be used more efficiently. The designed chip was fabricated with area of 0.3 mm2 using 0.18 μm BCDMOS process, and the bench-top test was also conducted to validate chip performance.

[1]  Fan-Gang Zeng,et al.  Cochlear Implants: System Design, Integration, and Evaluation , 2008, IEEE Reviews in Biomedical Engineering.

[2]  Richard H. Bayford,et al.  A Tripolar Current-Steering Stimulator ASIC for Field Shaping in Deep Brain Stimulation , 2012, IEEE Transactions on Biomedical Circuits and Systems.

[3]  S. Rauch,et al.  Deep Brain Stimulation of the Ventral Capsule/Ventral Striatum for Treatment-Resistant Depression , 2009, Biological Psychiatry.

[4]  J. Weiland,et al.  A variable range bi-phasic current stimulus driver circuitry for an implantable retinal prosthetic device , 2005, IEEE Journal of Solid-State Circuits.

[5]  David Daomin Zhou,et al.  Implantable Neural Prostheses 2 , 2010 .

[6]  P R Troyk,et al.  Injectable electronic identification, monitoring, and stimulation systems. , 1999, Annual review of biomedical engineering.

[7]  David Guiraud,et al.  A distributed architecture for activating the peripheral nervous system , 2009, Journal of neural engineering.

[8]  Justin C. Williams,et al.  Flexible polyimide-based intracortical electrode arrays with bioactive capability , 2001, IEEE Transactions on Biomedical Engineering.

[9]  R. Yuste,et al.  The Brain Activity Map Project and the Challenge of Functional Connectomics , 2012, Neuron.

[10]  Linh Hoang,et al.  An Integrated 256-Channel Epiretinal Prosthesis , 2010, IEEE Journal of Solid-State Circuits.

[11]  Rahul Sarpeshkar,et al.  A Low-Power Blocking-Capacitor-Free Charge-Balanced Electrode-Stimulator Chip With Less Than 6 nA DC Error for 1-mA Full-Scale Stimulation , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[12]  Sung June Kim,et al.  Design for a Simplified Cochlear Implant System , 2007, IEEE Transactions on Biomedical Engineering.

[13]  William M. Rabinowitz,et al.  Better speech recognition with cochlear implants , 1991, Nature.

[14]  David M. Landsberger,et al.  Virtual channel discrimination is improved by current focusing in cochlear implant recipients , 2009, Hearing Research.

[15]  Joonsoo Jeong,et al.  Monolithic Encapsulation of Implantable Neuroprosthetic Devices Using Liquid Crystal Polymers , 2011, IEEE Transactions on Biomedical Engineering.

[16]  P. Peckham,et al.  Functional electrical stimulation for neuromuscular applications. , 2005, Annual review of biomedical engineering.