Radiation Effects on the Silicon Semiconductor Detectors for the ASTRO-H Mission

Abstract Hard X-ray Imager (HXI) and Soft Gamma-ray Detector (SGD) onboard the 6th Japanese X-ray satellite, ASTRO–H, utilize double-sided silicon strip detectors (DSSD) and pixel array-type silicon sensors (Si-pad), respectively. The DSSD with a 3.4 cm×3.4 cm area has an imaging capability in the lower energy band for the HXI covering 5–80 keV. The Si-pad consists of 16×16 pixels with a 5.4 cm×5.4 cm area and measures a photon direction with the Compton kinematics in 10–600 keV. Since the ASTRO–H will be operated in a low earth orbit, these detectors will be damaged by irradiation of cosmic-ray protons mainly in the South Atlantic Anomaly. In order to evaluate damage effects of the sensors, we have carried out irradiation tests with 150 MeV proton beams and 60 Co gamma-rays with a total dose of 10–20 years irradiation level. In both experiments, the leakage current has increased by ∼ 0.2 − − 1.1 nA / cm 2 under an expected operation temperature at −15 °C, which resulted in the noise level within a tolerance of 20 years. In this report, we present a summary of the basic performance of silicon detectors, and radiation effects on them by the irradiation tests.

[1]  Yasushi Fukazawa,et al.  A high-energy resolution 4 cm-wide double-sided silicon strip detector , 2007 .

[2]  Yasushi Fukazawa,et al.  Development of double-sided silicon strip detectors (DSSD) for a Compton telescope , 2007 .

[3]  Krzysztof Iniewski Radiation Effects in Semiconductors , 2010 .

[4]  G. S. Varner,et al.  Improvement of radiation hardness of double-sided silicon strip detector for Belle SVD upgrade , 2000 .

[5]  Tuneyoshi Kamae,et al.  Hard X-Ray Detector (HXD) on Board Suzaku , 2006, astro-ph/0611232.

[6]  B. Reddell,et al.  Observations of the SAA radiation distribution by Liulin-E094 instrument on ISS , 2006 .

[7]  Hideo Hirayama,et al.  Radiation damage in silicon microstrip detectors , 1988 .

[8]  Hartmut Sadrozinski,et al.  An amplifier-discriminator chip for the GLAST silicon-strip tracker , 1997 .

[9]  J. R. Srour Radiation effects on and dose enhancement of electronic materials , 1984 .

[10]  Rene Donaldson,et al.  Proceedings of the 1984 Summer Study on the Design and Utilization of the Superconducting Super Collider, June 23-July 13, 1984, Snowmass, Colorado , 1984 .

[11]  Kazuhiro Nakazawa,et al.  Evaluation of 0.5-mm thick double-sided silicon strip detector for Compton telescope , 2007, SPIE Optical Engineering + Applications.

[12]  T. Takahashi,et al.  Design and performance of soft gamma-ray detector for NeXT mission , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[13]  B. Ramsey,et al.  IBIS: The Imager on-board INTEGRAL , 2003 .

[14]  P. Borgeaud,et al.  The effect of radiation on the energy resolution of ion-implanted silicon detectors , 1983 .

[15]  Yasushi Fukazawa,et al.  Development of low-noise double-sided silicon strip detector for cosmic soft gamma-ray compton camera , 2005 .