Relative expression software tool (REST©) for group-wise comparison and statistical analysis of relative expression results in real-time PCR

Real-time reverse transcription followed by polymerase chain reaction (RT-PCR) is the most suitable method for the detection and quantification of mRNA. It offers high sensitivity, good reproducibility and a wide quantification range. Today, relative expression is increasingly used, where the expression of a target gene is standardised by a non-regulated reference gene. Several mathematical algorithms have been developed to compute an expression ratio, based on real-time PCR efficiency and the crossing point deviation of an unknown sample versus a control. But all published equations and available models for the calculation of relative expression ratio allow only for the determination of a single transcription difference between one control and one sample. Therefore a new software tool was established, named REST (relative expression software tool), which compares two groups, with up to 16 data points in a sample and 16 in a control group, for reference and up to four target genes. The mathematical model used is based on the PCR efficiencies and the mean crossing point deviation between the sample and control group. Subsequently, the expression ratio results of the four investigated transcripts are tested for significance by a randomisation test. Herein, development and application of REST is explained and the usefulness of relative expression in real-time PCR using REST is discussed. The latest software version of REST and examples for the correct use can be downloaded at http://www.wzw.tum.de/gene-quantification/.

[1]  N. Sivasubramanian,et al.  Rapid Cycle Real-Time PCR — Methods and Applications , 2002, Springer Berlin Heidelberg.

[2]  C Lockey,et al.  Real-time fluorescence detection of a single DNA molecule. , 1998, BioTechniques.

[3]  C. Mannhalter,et al.  Evaluation of RNA Isolation Methods and Reference Genes for RT-PCR Analyses of Rare Target RNA , 2000, Clinical chemistry and laboratory medicine.

[4]  M P Murtaugh,et al.  Regulation of hypoxanthine phosphoribosyltransferase, glyceraldehyde-3-phosphate dehydrogenase and beta-actin mRNA expression in porcine immune cells and tissues. , 1998, Animal biotechnology.

[5]  N. Steuerwald,et al.  Analysis of gene expression in single oocytes and embryos by real-time rapid cycle fluorescence monitored RT-PCR. , 1999, Molecular human reproduction.

[6]  G. Haberhausen,et al.  Comparative Study of Different Standardization Concepts in Quantitative Competitive Reverse Transcription-PCR Assays , 1998, Journal of Clinical Microbiology.

[7]  T. Grisar,et al.  Housekeeping genes as internal standards: use and limits. , 1999, Journal of biotechnology.

[8]  A. W. Kemp,et al.  Randomization, Bootstrap and Monte Carlo Methods in Biology , 1997 .

[9]  C. Chi,et al.  Up-regulation of beta-actin, cyclophilin and GAPDH in N1S1 rat hepatoma. , 1998, Oncology reports.

[10]  J. Ordovás,et al.  Quantification of mRNA by polymerase chain reaction (PCR) using an internal standard and a nonradioactive detection method. , 1998, Methods in molecular biology.

[11]  C. Heid,et al.  A novel method for real time quantitative RT-PCR. , 1996, Genome research.

[12]  C. Marquis,et al.  Comparison of the efficiency of Moloney Murine Leukaemia Virus (M-MuLV) reverse transcriptase, RNase H--M-MuLV reverse transcriptase and Avian Myeloblastoma Leukaemia Virus (AMV) reverse transcriptase for the amplification of human immunoglobulin genes , 1998 .

[13]  Russell Higuchi,et al.  Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions , 1993, Bio/Technology.

[14]  R. Rasmussen Quantification on the LightCycler , 2001 .

[15]  J. Bereta,et al.  Stimulation of glyceraldehyde-3-phosphate dehydrogenase mRNA levels by endogenous nitric oxide in cytokine-activated endothelium. , 1995, Biochemical and biophysical research communications.

[16]  S. Snyder,et al.  Nitric oxide stimulates auto-ADP-ribosylation of glyceraldehyde-3-phosphate dehydrogenase. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[17]  M. Pfaffl Development and Validation of an Externally Standardised Quantitative Insulin-like Growth Factor-1 RT-PCR Using LightCycler SYBR Green I Technology , 2001 .

[18]  D. Straus,et al.  Effect of amino acid limitation on the expression of 19 genes in rat hepatoma cells , 1994, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[19]  U J Balis,et al.  The LightCycler: a microvolume multisample fluorimeter with rapid temperature control. , 1997, BioTechniques.

[20]  S. Bustin Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays. , 2000, Journal of molecular endocrinology.

[21]  M. Pazzagli,et al.  Developments in Quantitative PCR , 1998, Clinical chemistry and laboratory medicine.

[22]  P Kainz,et al.  The PCR plateau phase - towards an understanding of its limitations. , 2000, Biochimica et biophysica acta.

[23]  W. Taylor,et al.  Comparison of glyceraldehyde-3-phosphate dehydrogenase and 28S-ribosomal RNA gene expression as RNA loading controls for northern blot analysis of cell lines of varying malignant potential. , 1994, Analytical biochemistry.

[24]  M. Pfaffl,et al.  A new mathematical model for relative quantification in real-time RT-PCR. , 2001, Nucleic acids research.

[25]  M. Pfaffl,et al.  Validities of mRNA quantification using recombinant RNA and recombinant DNA external calibration curves in real-time RT-PCR , 2001, Biotechnology Letters.

[26]  M. Pfaffl,et al.  Quantification of insulin-like growth factor-1 (IGF-1) mRNA: Development and validation of an internally standardised competitive reverse transcription-polymerase chain reaction , 2009, Experimental and clinical endocrinology & diabetes : official journal, German Society of Endocrinology [and] German Diabetes Association.