Adaptive optics microscopy with direct wavefront sensing using fluorescent protein guide stars.

We introduce a direct wavefront sensing method using structures labeled with fluorescent proteins in tissues as guide stars. An adaptive optics confocal microscope using this method is demonstrated for imaging of mouse brain tissue. A dendrite and a cell body of a neuron labeled with yellow fluorescent protein are tested as guide stars without injection of other fluorescent labels. Photobleaching effects are also analyzed. The results shows increased image contrast and 3× improvement in the signal intensity for fixed mouse tissues at depths of 70 μm.

[1]  Xiaodong Tao,et al.  Adaptive optics confocal microscopy using direct wavefront sensing. , 2011, Optics letters.

[2]  Martin J. Booth,et al.  Adaptive optics in microscopy , 2003, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[3]  Stephen A Burns,et al.  In vivo fluorescent imaging of the mouse retina using adaptive optics. , 2007, Optics letters.

[4]  Sidney Udenfriend,et al.  PRINCIPLES OF FLUORESCENCE , 1969 .

[5]  Donald T. Gavel,et al.  Performance of MEMS-based visible-light adaptive optics at Lick Observatory: closed- and open-loop control , 2010, Astronomical Telescopes + Instrumentation.

[6]  J C Dainty,et al.  Single-pass measurements of the wave-front aberrations of the human eye by use of retinal lipofuscin autofluorescence. , 1999, Optics letters.

[7]  R V Shack,et al.  Measurement of the three‐dimensional microscope point spread function using a Shack–Hartmann wavefront sensor , 2002, Journal of microscopy.

[8]  D. Gavel,et al.  Adaptive optics wide-field microscopy using direct wavefront sensing. , 2011, Optics letters.

[9]  Tony Wilson,et al.  Image-based adaptive optics for two-photon microscopy. , 2009, Optics letters.

[10]  Lisa A Poyneer,et al.  Fast wave-front reconstruction in large adaptive optics systems with use of the Fourier transform. , 2002, Journal of the Optical Society of America. A, Optics, image science, and vision.

[11]  Gerard Rousset,et al.  Comparison of centroid computation algorithms in a Shack–Hartmann sensor , 2006 .

[12]  Donald Gavel,et al.  Adaptive optics wide-field microscope corrections using a MEMS DM and Shack-Hartmann wavefront sensor , 2011, MOEMS-MEMS.

[13]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[14]  Daren Dillon,et al.  Wavefront aberration measurements and corrections through thick tissue using fluorescent microsphere reference beacons , 2010, Optics express.

[15]  W. Denk,et al.  Adaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing , 2006, Proceedings of the National Academy of Sciences.