On the use of S-transform for fault feeder detection based on two phase currents in distribution power systems

The paper presents a procedure for fault feeder detection in distribution power systems, based on the use of the amplitude-time and argument-time by S-transform of the zero-module bus voltage and two phase currents transients associated with the fault-originated traveling waves. The analysis carried out shows that the argument of currents have difference 180° between fault feeder and sound feeders at fault-originated which make fault feeder detectible. A large number of simulation results demonstrate the feasibility and validity of the procedure.

[1]  Dong Hai-bo STUDY ON EARTHED FAULT LOCATION METHOD IN INDIRECTLY GROUNDING POWER SYSTEM USING MAXIMUM VALUE OFABSOLUTE VALUE SUMMATION OF MEASUREMENT ADMITTANCE MUTUAL DIFFERENCE , 2005 .

[2]  Jiang Na A CORRELATION ANALYSIS BASED METHOD TO DETECT FAULTY LINE UNDER SINGLE PHASE TO GROUND FAULT OCCURRED IN DISTRIBUTION NETWORK WITH SMALL CURRENT NEUTRAL GROUNDING , 2004 .

[3]  Ding Yi-feng,et al.  S-TRANSFORM-BASED CLASSIFICATION OF POWER QUALITY DISTURBANCE SIGNALS BY SUPPORT VECTOR MACHINES , 2005 .

[4]  Si Da-jun New approach for fault line selection in distribution system with arc suppressing coil grounding using decaying DC component , 2006 .

[5]  Zhao Xing-bing,et al.  A New Approach to Detect Fault Line in Resonant Earthed System Using Simulation After Test , 2008 .

[6]  Zhang Jie Adaptive Method for Fault Circuit Selection in Arc Suppression Coils System by Using Transient Energy , 2006 .

[7]  Wang Yao-nan A NEW CRITERION FOR EARTH FAULT LINE SELECTION BASED ON WAVELET PACKETS IN SMALL CURRENT NEUTRAL GROUNDING SYSTEM , 2004 .

[8]  Bi Jian-guang Test of Fault Line Selector Based on Current Traveling Wave , 2006 .

[9]  Zhao Xing-bing A New Fault Line Detection Method for Hybrid Transmission Lines of Distribution Network , 2008 .

[10]  Li Xinbin,et al.  Singularity Detection for Phase-to-ground Fault in Non-effective Grounded Power Networks Based on Multi-frequency Bands Analysis , 2007 .

[11]  Wang Yong-hui A study of earth fault detection by comparing phase of initial transient traveling wave , 2008 .

[12]  Pradipta Kishore Dash,et al.  S-transform-based intelligent system for classification of power quality disturbance signals , 2003, IEEE Trans. Ind. Electron..

[13]  Lalu Mansinha,et al.  Localization of the complex spectrum: the S transform , 1996, IEEE Trans. Signal Process..

[14]  Yang Hua A NEW PRINCIPLE OF TRANSIENT CURRENT GROUNDED RELAY FOR FEEDER IN UNGROUNDED DISTRIBUTION SYSTEMS , 2004 .