Effect of the homogeneity of the column set on the performance of a simulated moving bed unit. I. Theory.

Although it is impossible to manufacture identical columns for use in a simulated moving bed (SMB) process, theoretical studies assume that all the columns in an SMB unit have identical characteristics. In practice, calculations in modeling and optimization studies are made with the average values of each column parameter set. In this report, the effects on SMB process performance caused by column-to-column fluctuations of the parameters are discussed. As a first step, we show how the differences in porosity of the columns may be taken into account with a revised set of separation conditions. Reductions in the purity of the extract and the raffinate streams are quantitatively related to the column-to-column fluctuations of the retention times of the two components arising from these porosity differences. For the sake of simplicity, the discussion first addresses the case of a four-column SMB operating under linear conditions. Then, the scope is extended to the cases of SMB units incorporating several columns in each section and to SMB units operating under nonlinear conditions.

[1]  F. Antia,et al.  Enantioseparation of a chiral epoxide by simulated moving bed chromatography using Chiralcel-OD , 1995 .

[2]  Enantioseparation of 1-phenyl-1-propanol by simulated moving bed under linear and nonlinear conditions. , 2000, Journal of chromatography. A.

[3]  E. Glueckauf,et al.  239. Theory of chromatography. Part II. Chromatograms of a single solute , 1947 .

[4]  Gerard Hotier,et al.  Remote Raman spectroscopy for process control , 1995 .

[5]  M. Morbidelli,et al.  On-line monitoring of enantiomer concentration in chiral simulated moving bed chromatography. , 2000, Journal of chromatography. A.

[6]  G. Guiochon,et al.  Effect of column efficiency on the internal concentration profiles and the performance of a simulated moving-bed unit in the case of a linear isotherm , 1997 .

[7]  T. L. Hill,et al.  An Introduction to Statistical Thermodynamics , 1960 .

[8]  G. Guiochon,et al.  Experimental study of the influence of the flow rates in SMB chromatography , 1997 .

[9]  Massimo Morbidelli,et al.  Simulated moving‐bed units with extra‐column dead volume , 1999 .

[10]  Andreas Seidel-Morgenstern,et al.  Design of the simulated moving bed process based on adsorption isotherm measurements using a perturbation method , 1998 .

[11]  G. Guiochon,et al.  Thermodynamics of the adsorption of Tröger's base enantiomers from ethanol on cellulose triacetate , 1993 .

[12]  G. Grévillot,et al.  Equilibria and activity coefficients for non-ideal adsorbed mixtures from perturbation chromatography , 1998 .

[13]  Design and performance of a simulated countercurrent moving‐bed separator , 1993 .

[14]  M. Douglas LeVan,et al.  Fundamentals of Adsorption , 1996 .

[15]  Massimo Morbidelli,et al.  Experimental analysis of a chiral separation through simulated moving bed chromatography , 1999 .

[16]  Roger-Marc Nicoud,et al.  Complete design of a simulated moving bed , 1995 .

[17]  Georges Guiochon,et al.  Analytical solution for the linear ideal model of simulated moving bed chromatography , 1996 .

[18]  Zidu Ma,et al.  Optimization of throughput and desorbent consumption in simulated moving-bed chromatography for paclitaxel purification. , 1999, Journal of chromatography. A.

[19]  Massimo Morbidelli,et al.  Optimal operation of simulated moving bed units for nonlinear chromatographic separations , 1997 .

[20]  Masakazu Negawa,et al.  Optical resolution by simulated moving-bed adsorption technology , 1992 .

[21]  S. Harris,et al.  Silica-bonded calixarenes in chromatography: I. Synthesis and characterization by solid-state NMR spectroscopy , 1996 .

[22]  Ernst Dieter Gilles,et al.  Automatic control of the simulated moving bed process for C8 aromatics separation using asymptotically exact input/output-linearization , 1999 .

[23]  G. Guiochon,et al.  Study of the operating conditions of axial compression columns for preparative chromatography , 1995 .

[24]  Massimo Morbidelli,et al.  Design of Simulated Moving Bed Units under Nonideal Conditions , 1999 .

[25]  F. Meunier Fundamentals of adsorption 6 , 1998 .

[26]  Sebastian Engell,et al.  Model-based optimization and control of chromatographic processes , 2000 .

[27]  F. G. Sánchez,et al.  Resolution of deltamethrin, permethrin, and cypermethrin enantiomers by high-performance liquid chromatography with diode-laser polarimetric detection , 1998 .

[28]  C. Ching,et al.  Preparative resolution of praziquantel enantiomers by simulated counter-current chromatography , 1993 .

[29]  Georges Guiochon,et al.  Adsorption isotherm and overloaded elution profiles of phenyldodecane on porous carbon in liquid chromatography , 1991 .

[30]  P. Hubert,et al.  Comparative evaluation of four detectors in the high-performance liquid chromatographic analysis of chiral nonaromatic alcohols. , 2000, Journal of chromatographic science.

[31]  M. Morbidelli,et al.  Design and optimisation of a simulated moving bed unit: role of deviations from equilibrium theory. , 2000, Journal of chromatography. A.

[32]  D. Ruthven,et al.  Counter-current and simulated counter-current adsorption separation processes , 1989 .

[33]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[34]  G. Ganetsos,et al.  Preparative and Production Scale Chromatography , 1992 .

[35]  Yoshihito Shirai,et al.  A simulated moving-bed adsorber for the separation of tricomponents , 1993 .

[36]  G. Guiochon,et al.  Theoretical analysis of the behavior of an heterogeneously packed chromatographic column , 1998 .

[37]  D. Goodall Chiral analysis based on polarimetric detection , 1993 .

[38]  Massimo Morbidelli,et al.  Optimal design of multicomponent countercurrent adsorption separation processes involving nonlinear equilibria , 1989 .

[39]  Massimo Morbidelli,et al.  Robust design of binary countercurrent adsorption separation processes , 1993 .

[40]  S. Sekulic,et al.  APPLICATIONS OF A SENSITIVE LASER POLARIMETRIC HPLC DETECTOR: CONFIRMATION OF ENANTIOMERIC EXCESS FOR DANOFLOXACIN AND ANALYSIS OF A NOVEL MACROLIDE , 2000 .

[41]  A. Rodrigues,et al.  Enantiomers separation by simulated moving bed chromatography. Non-instantaneous equilibrium at the solid-fluid interface. , 1999, Journal of Chromatography A.

[42]  Massimo Morbidelli,et al.  Continuous chromatographic separation through simulated moving beds under linear and nonlinear conditions , 1998 .

[43]  G. Guiochon,et al.  On the reproducibility of column performance in liquid chromatography and the role of the packing density , 1997 .