Study of micromotion in modular acetabular components during gait and subluxation: a finite element investigation.

Polyethylene wear after total hip arthroplasty may occur as a result of normal gait and as a result of subluxation and relocation with impact. Relocation of a subluxed hip may impart a moment to the cup creating sliding as well as compression at the cup liner interface. The purpose of the current study is to quantify, by a validated finite element model, the forces generated in a hip arthroplasty as a result of subluxation relocation and compare them to the forces generated during normal gait. The micromotion between the liner and acetabular shell was quantified by computing the sliding track and the deformation at several points of the interface. A finite element analysis of polyethylene liner stress and liner/cup micromotion in total hip arthroplasty was performed under two dynamic profiles. The first profile was a gait loading profile simulating the force vectors developed in the hip arthroplasty during normal gait. The second profile is generated during subluxation and subsequent relocation of the femoral head. The forces generated by subluxation relocation of a total hip arthroplasty can exceed those forces generated during normal gait. The induced micromotion at the cup polyethylene interface as a result of subluxation can exceed micromotion as a result of the normal gait cycle. This may play a significant role in the generation of backsided wear. Minimizing joint subluxation by restoring balance to the hip joint after arthroplasty should be explored as a strategy to minimize backsided wear.

[1]  D A Dennis,et al.  An in vivo determination of total hip arthroplasty pistoning during activity. , 2000, The Journal of arthroplasty.

[2]  T. Pace Clinical evaluation of a new total hip prosthetic design: 100 consecutive cementless total hip arthroplasties using Sulzermedica's "Natural Hip" with two- to six-year clinical and radiographic follow-up. , 2000, Critical reviews in biomedical engineering.

[3]  B M Wroblewski,et al.  The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. , 1995, The Journal of bone and joint surgery. American volume.

[4]  T. Kubo,et al.  A 10- to 13-year follow-up study of Harris-Galante type prosthesis in total hip arthroplasty , 2000, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[5]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[6]  D. Bartel,et al.  The role of backside polishing, cup angle, and polyethylene thickness on the contact stresses in metal-backed acetabular components. , 1997, Journal of biomechanics.

[7]  E Y Chao,et al.  A survey of finite element analysis in orthopedic biomechanics: the first decade. , 1983, Journal of biomechanics.

[8]  Jaroslav Mackerle,et al.  FINITE AND BOUNDARY ELEMENT METHODS IN BIOMECHANICS: A BIBLIOGRAPHY (1976–1991) , 1992 .

[9]  G. Bergmann,et al.  Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.

[10]  T. Bauer,et al.  Three-Dimensional Analysis of Multiple Wear Vectors in Retrieved Acetabular Cups* , 1997, The Journal of bone and joint surgery. American volume.

[11]  O. Nercessian,et al.  Clinical and radiographic results of cementless AML total hip arthroplasty in young patients. , 2001, The Journal of arthroplasty.

[12]  A. Kapandji,et al.  Cementless primary total hip replacement , 1998, International Orthopaedics.

[13]  W. Harris,et al.  The problem is osteolysis. , 1995, Clinical orthopaedics and related research.

[14]  R A Brand,et al.  Mathematical modelling of stress in the hip during gait. , 1999, Journal of biomechanics.

[15]  R. Brand,et al.  Comparison of hip force calculations and measurements in the same patient. , 1994, The Journal of arthroplasty.

[16]  C. D. Han,et al.  Effect of polyethylene wear on osteolysis in cementless primary total hip arthroplasty: minimal 5-year follow-up study. , 1999, The Journal of arthroplasty.

[17]  A. Unsworth,et al.  The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement. , 1999, Journal of biomedical materials research.

[18]  R Huiskes,et al.  From structure to process, from organ to cell: recent developments of FE-analysis in orthopaedic biomechanics. , 1993, Journal of biomechanical engineering.

[19]  C. V. White,et al.  Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. , 1998, Journal of biomechanics.

[20]  S H Teoh,et al.  An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty. , 2002, Journal of biomechanics.

[21]  T P Schmalzried,et al.  The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. , 1994, The Journal of bone and joint surgery. American volume.

[22]  R. Bourne,et al.  Uncemented total hip arthroplasty in patients 50 years of age or younger. , 1997, The Journal of arthroplasty.

[23]  M Honl,et al.  Duration and frequency of every day activities in total hip patients. , 2001, Journal of biomechanics.

[24]  D A Dennis,et al.  "In vivo" determination of hip joint separation and the forces generated due to impact loading conditions. , 2001, Journal of biomechanics.

[25]  A Rohlmann,et al.  Hip Joint Forces During Load Carrying , 1997, Clinical orthopaedics and related research.

[26]  E. Schneider,et al.  The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation. , 2001, Journal of biomechanics.

[27]  D L Bartel,et al.  The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. , 1985, Journal of biomechanical engineering.

[28]  R. Barrack,et al.  Pelvic Lysis and Polyethylene Wear at 5–8 Years in an Uncemented Total Hip , 1997, Clinical orthopaedics and related research.

[29]  C. V. White,et al.  Simulation of initial frontside and backside wear rates in a modular acetabular component with multiple screw holes. , 1999, Journal of biomechanics.

[30]  P. Rullkoetter,et al.  Finite element simulation of early creep and wear in total hip arthroplasty. , 2005, Journal of biomechanics.

[31]  Mark H. Gonzalez,et al.  AN EXPERIMENTAL ANALYSIS OF MICROMOTION OF A CEMENTLESS MODULAR ACETABULAR COMPONENT IN TOTAL HIP ARTHROPLASTY : EVALUATION OF THE BONE AND CUP LINER INTERFACES UNDER PHYSIOLOGIC LOADS , 2002 .

[32]  Olof Calonius,et al.  Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. , 2002, Journal of biomechanics.

[33]  S. G. Capps,et al.  Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty. , 2001, The Journal of arthroplasty.

[34]  Michael Tanzer,et al.  Primary cementless total hip arthroplasty using a modular femoral component: a minimum 6-year follow-up. , 2001, The Journal of arthroplasty.