Methods to Determine Ductility of Structural Members: A Review

Ductility plays a crucial role in ensuring the safety of a structure, as its inadequacy can lead to sudden and brittle failure. Despite its significance, there is no explicit method for determining, leading to inconsistency and confusion in selecting appropriate techniques. Misjudging a structure’s ductile behaviour can have catastrophic consequences. Therefore, this study examined several preliminary studies and identified twenty-one methods for computing ductility indices. These indices were categorized into three types, namely conventional, displacement-based, and energy-based. The conventional ductility indices are commonly applied to steel-reinforced members, deformation-based ductility indices to FRP-reinforced members, and energy-based ductility indices to earthquake-resistant and static-load structures. Conventional ductility indices are specific to ductile reinforcements, while displacement-based and energy-based ductility indices apply to both ductile and non-ductile reinforcements. However, different calculation methods can lead to significant variations in the computed ductility, particularly for those involving the first crack, and load factor, thereby leading to different ductility requirements for ensuring structural safety. Additionally, not all methods are explicit, and it is crucial to avoid indiscriminately applying requirements from one method to another.

[1]  Zhishen Wu,et al.  Long-term flexural behavior of concrete beams with hybrid FRP and steel reinforcements in simulated marine environment , 2021 .

[2]  Lim Yong Tat,et al.  Experimental Study on the Flexural Behavior of Reinforced Polystyrene Blocks in Concrete Beams , 2021 .

[3]  Ahmed W. Al Zand,et al.  Characteristics of experimental ductility energy index of hybrid-CFRP reinforced concrete deep beams , 2021, SN Applied Sciences.

[4]  Yinghao Zhu,et al.  Stiffness assessment of cracked post-tensioned concrete beams with unbonded tendons based on the cracking pattern , 2020 .

[5]  Effects of Transverse Circular Opening in Reinforced Concrete Beam Subjected to Incremental Static Load , 2019, Borneo Journal of Sciences and Technology.

[6]  318-19 Building Code Requirements for Structural Concrete and Commentary , 2019 .

[7]  Mohamed E. El Madawy,et al.  Effect of glass-fiber rods on the ductile behaviour of reinforced concrete beams , 2018 .

[8]  Cheng-Cheng Chen,et al.  Effect of Intermediate Stiffeners on the Behaviors of Partially Concrete Encased Steel Beams , 2018, Advances in Civil Engineering.

[9]  A. N. Dancygier,et al.  Cracking localization and reduced ductility in fiber-reinforced concrete beams with low reinforcement ratios , 2016 .

[10]  B. Praveen,et al.  Ductility of Reinforced Concrete Beams , 2015 .

[11]  Mehrollah Rakhshanimehr,et al.  Flexural ductility of reinforced concrete beams with lap-spliced bars , 2014 .

[12]  M. Eatherton,et al.  Concrete filled steel plate composite coupling beams: Experimental study , 2014 .

[13]  A. Ghallab Ductility of externally prestressed continuous concrete beams , 2014, KSCE Journal of Civil Engineering.

[14]  F. Oudah,et al.  A new ductility model of reinforced concrete beams strengthened using Fiber Reinforced Polymer reinforcement , 2012 .

[15]  Manuel L. Romero,et al.  Ductility of slender reinforced concrete columns under monotonic flexure and constant axial load , 2012 .

[16]  H. Wang,et al.  Ductility characteristics of fiber-reinforced-concrete beams reinforced with FRP rebars , 2011 .

[17]  I. Jang,et al.  On the Ductility of High-Strength Concrete Beams , 2008 .

[18]  Frederic Legeron,et al.  Confinement Reinforcement Design for Reinforced Concrete Columns , 2008 .

[19]  Yufei Wu New Avenue of Achieving Ductility for Reinforced Concrete Members , 2006 .

[20]  Suchart Limkatanyu,et al.  Failure Mode Analyses of Reinforced Concrete Beams Strengthened in Flexure with Externally Bonded Fiber-Reinforced Polymers , 2004 .

[21]  R. Delpak,et al.  DUCTILITY AND DEFORMABILITY OF FIBRE-REINFORCED POLYMER-STRENGTHENED REINFORCED CONCRETE BEAMS , 2004 .

[22]  Patrick X.W. Zou,et al.  Flexural Behavior and Deformability of Fiber Reinforced Polymer Prestressed Concrete Beams , 2003 .

[23]  A. E. Naaman,et al.  FRP REINFORCEMENTS IN STRUCTURAL CONCRETE: ASSESSMENT, PROGRESS AND PROSPECTS , 2003 .

[24]  Akh Kwan,et al.  Flexural strength and ductility of reinforced normal- and high-strength concrete beams , 2001 .

[25]  R. N. Swamy,et al.  Strength and Ductility of RC Beams Repaired with Bonded CFRP Laminates , 2001 .

[26]  Samir A. Ashour,et al.  Effect of compressive strength and tensile reinforcement ratio on flexural behavior of high-strength concrete beams , 2000 .

[27]  Mo Shing Cheung,et al.  Canadian Bridge Design Code Provisions for Fiber-Reinforced Structures , 2000 .

[28]  Abdulrahman Alhozaimy,et al.  Ductility of Concrete Beams Reinforced with FRP Bars and Steel Fibers , 1999 .

[29]  Nabil F. Grace,et al.  Behavior and Ductility of Simple and Continuous FRP Reinforced Beams , 1998 .

[30]  Michèle Thériault,et al.  Effects of FRP Reinforcement Ratio and Concrete Strength on Flexural Behavior of Concrete Beams , 1998 .

[31]  Paolo Emilio Pinto,et al.  DUCTILITY REQUIREMENTS FOR REINFORCEMENT UNDER EUROCODES , 1996 .

[32]  Sami H. Rizkalla,et al.  Test Model for the First Canadian Smart Highway Bridge , 1995 .

[33]  Sami H. Rizkalla,et al.  Horizontal Connections for Precast Concrete Shear Walls Subjected to Cyclic Deformations Part 1: Mild Steel Connections , 1995 .

[34]  A. Pan,et al.  Lateral Displacement Ductility of Reinforced Concrete Flat Plates , 1989 .

[35]  Nasr Z. Hassan,et al.  Study Behavior of Hollow Reinforced Concrete Beams , 2018 .

[36]  J. Ho Flexural strength and ductility of reinforced concrete beams , 2013 .

[37]  I. Imran,et al.  EXPERIMENTAL STUDY OF CONFINED LOW, MEDIUM AND HIGH-STRENGTH CONCRETE SUBJECTED TO CONCENTRIC COMPRESSION , 2012 .

[38]  R. N. Swamy,et al.  Strengthening and Upgrading Structures with Bonded CFRP Sheets: Design Aspects for Structural Integrity , 1997 .

[39]  G Tadros,et al.  DEFORMABILITY VERSUS DUCTILITY IN CONCRETE BEAMS WITH FRP REINFORCEMENT , 1996 .

[40]  Sang-Mo Jeong,et al.  Evaluation of ductility in prestressed concrete beams using fiber-reinforced plastic tendons. , 1994 .

[41]  Gert Heshe,et al.  DS/ENV 1992-1-1 NAD. National Application Document for Eurocode 2: Design of Concrete Structures, Part 1-1: General Rules and Rules for Buildings , 1993 .

[42]  H. Wright Proceedings of the Institution of Civil Engineers - Structures and Buildings , 1992 .