Self-sensing of temperature rises on light emitting diode based optrodes

Abstract Objective. This work presents a method to determine the surface temperature of microphotonic medical implants like LEDs. Our inventive step is to use the photonic emitter (LED) employed in an implantable device as its own sensor and develop readout circuitry to accurately determine the surface temperature of the device. Approach. There are two primary classes of applications where microphotonics could be used in implantable devices; opto-electrophysiology and fluorescence sensing. In such scenarios, intense light needs to be delivered to the target. As blue wavelengths are scattered strongly in tissue, such delivery needs to be either via optic fibres, two-photon approaches or through local emitters. In the latter case, as light emitters generate heat, there is a potential for probe surfaces to exceed the 2 °C regulatory. However, currently, there are no convenient mechanisms to monitor this in situ. Main results. We present the electronic control circuit and calibration method to monitor the surface temperature change of implantable optrode. The efficacy is demonstrated in air, saline, and brain. Significance. This paper, therefore, presents a method to utilize the light emitting diode as its own temperature sensor.

[1]  Stefan R. Pulver,et al.  Ultra-sensitive fluorescent proteins for imaging neuronal activity , 2013, Nature.

[2]  Ahmed Soltan,et al.  High density, high radiance μLED matrix for optogenetic retinal prostheses and planar neural stimulation , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[3]  F. Udrea,et al.  CMOS temperature sensors - concepts, state-of-the-art and prospects , 2008, 2008 International Semiconductor Conference.

[4]  Pleun Maaskant,et al.  High-Speed Substrate-Emitting Micro-Light-Emitting Diodes for Applications Requiring High Radiance , 2013 .

[5]  H. A. Alzaher,et al.  A CMOS fully balanced second-generation current conveyor , 2003 .

[6]  E. Fred Schubert,et al.  Transport-mechanism analysis of the reverse leakage current in GaInN light-emitting diodes , 2011 .

[7]  Samir Ben Salem,et al.  A high performances CMOS CCII and high frequency applications , 2006 .

[8]  G. Buzsáki,et al.  An implantable neural probe with monolithically integrated dielectric waveguide and recording electrodes for optogenetics applications , 2013, Journal of neural engineering.

[9]  Erika Pastrana,et al.  Optogenetics: controlling cell function with light , 2011, Nature Methods.

[10]  O. Paul,et al.  Miniaturized 3×3 optical fiber array for optogenetics with integrated 460 nm light sources and flexible electrical interconnection , 2015, 2015 28th IEEE International Conference on Micro Electro Mechanical Systems (MEMS).

[11]  A. Demchenko Introduction to Fluorescence Sensing , 2008, Springer International Publishing.

[12]  K. Mathieson,et al.  Thermal and optical characterization of micro-LED probes for in vivo optogenetic neural stimulation. , 2013, Optics letters.

[13]  E. Bamberg,et al.  Channelrhodopsin-2, a directly light-gated cation-selective membrane channel , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[14]  Kenji F. Tanaka,et al.  The manipulation of neural and cellular activities by ectopic expression of melanopsin , 2013, Neuroscience Research.

[15]  Patrick Degenaar,et al.  Arrays of MicroLEDs and Astrocytes: Biological Amplifiers to Optogenetically Modulate Neuronal Networks Reducing Light Requirement , 2014, PloS one.

[16]  Hung Cao,et al.  An Integrated μLED Optrode for Optogenetic Stimulation and Electrical Recording , 2013, IEEE Transactions on Biomedical Engineering.

[17]  R. Normann,et al.  Thermal Impact of an Active 3-D Microelectrode Array Implanted in the Brain , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[18]  Y. Ibata,et al.  Effects of heating on electrical activities of guinea pig olfactory cortical slices , 2004, Pflügers Archiv.

[19]  Patrick Degenaar,et al.  This Work Is Licensed under a Creative Commons Attribution 4.0 International License Blockade of Pathological Retinal Ganglion Cell Hyperactivity Improves Optogenetically Evoked Light Responses in Rd1 Mice , 2022 .

[20]  Ching-Hsing Luo,et al.  CMOS thermal sensing system with simplified circuits and high accuracy for biomedical application , 2006, 2006 IEEE International Symposium on Circuits and Systems.

[21]  F. Dehkhoda,et al.  Smart optrode for neural stimulation and sensing , 2015, 2015 IEEE SENSORS.

[22]  J. Barrett,et al.  Optogenetic approaches to retinal prosthesis , 2014, Visual Neuroscience.

[23]  Tien-Mo Shih,et al.  Junction-Temperature Determination in InGaN Light-Emitting Diodes Using Reverse Current Method , 2013, IEEE Transactions on Electron Devices.

[24]  Jiangang Du,et al.  Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes , 2011, PloS one.

[25]  R. A. Bianchi,et al.  CMOS-compatible smart temperature sensors , 1998 .

[26]  Feng Zhang,et al.  Multimodal fast optical interrogation of neural circuitry , 2007, Nature.

[27]  Garret D Stuber,et al.  Construction of implantable optical fibers for long-term optogenetic manipulation of neural circuits , 2011, Nature Protocols.

[28]  Roger Y. Tsien,et al.  Improved green fluorescence , 1995, Nature.

[29]  Hamish Meffin,et al.  Retinal prosthesis safety: alterations in microglia morphology due to thermal damage and retinal implant contact. , 2012, Investigative ophthalmology & visual science.

[30]  H Harasaki,et al.  Heat From an Implanted Power Source Is Mainly Dissipated by Blood Perfusion , 1997, ASAIO journal.

[31]  T. Seese,et al.  Characterization of tissue morphology, angiogenesis, and temperature in the adaptive response of muscle tissue to chronic heating. , 1998, Laboratory investigation; a journal of technical methods and pathology.

[32]  M. Dewhirst,et al.  Summary, conclusions and recommendations: adverse temperature levels in the human body , 2003, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[33]  E. Moriyama,et al.  Thermal damage threshold of brain tissue--histological study of heated normal monkey brains. , 1994, Neurologia medico-chirurgica.

[34]  Karl Deisseroth,et al.  Optogenetics in Neural Systems , 2011, Neuron.

[35]  Wei Hu,et al.  A CMOS Smart Temperature Sensor With Single-Point Calibration Method for Clinical Use , 2016, IEEE Transactions on Circuits and Systems II: Express Briefs.

[36]  Otto J. Prohaska,et al.  Stimulus-activated changes in brain tissue temperature in the anesthetized rat , 1989, Metabolic Brain Disease.

[37]  G. Buzsáki,et al.  Monolithically Integrated μLEDs on Silicon Neural Probes for High-Resolution Optogenetic Studies in Behaving Animals , 2015, Neuron.

[38]  J. Gordon,et al.  Modeling the Spatiotemporal Dynamics of Light and Heat Propagation for In Vivo Optogenetics. , 2015, Cell reports.

[40]  Che-Wei Huang,et al.  A self-powered CMOS reconfigurable multi-sensor SoC for biomedical applications , 2013, 2013 Symposium on VLSI Circuits.

[41]  June Key Lee,et al.  Leakage Current Analysis of GaN-Based Light-Emitting Diodes Using a Parasitic Diode Model , 2015, IEEE Transactions on Electron Devices.