Sensitive electrochemical detection of horseradish peroxidase at disposable screen-printed carbon electrode.

A rapid, simple and sensitive electrochemical assay of horseradish peroxidase (HRP) performed on disposable screen-printed carbon electrode was developed. HRP activities were monitored by square-wave voltammetric (SWV) measuring the electroactive enzymatic product in the presence of o-aminophenol and hydrogen peroxide substrate solution. SWV analysis demonstrated a greater sensitivity and shorter analysis time than the widely used amperometric and differential-pulsed voltammetric methods. The voltammetric characteristics of substrate and enzymatic product as well as the parameters of SWV analysis were optimized. Under optimized conditions, a linear response for HRP from 0.003 - 0.1 U/mL and a detection limit of 0.002 U/mL (1.25×10(-15) mol in 25 μL) were obtained with a good precision (RSD = 8%; n = 6). This rapid and sensitive HRP assay with microliters-assay volume could be readily integrated to portable devices and point-of-care (POC) diagnosis applications.

[1]  J. Lanciego,et al.  Detection of two different mRNAs in a single section by dual in situ hybridization: A comparison between colorimetric and fluorescent detection , 2007, Journal of Neuroscience Methods.

[2]  Huangxian Ju,et al.  Layer-by-layer hydroxymethyl ferrocene modified sensor for one-step flow/stop-flow injection amperometric immunoassay of alpha-fetoprotein. , 2007, Biosensors & bioelectronics.

[3]  P. Gill,et al.  Production of Anti‐Digoxigenin Antibody HRP Conjugate for PCR‐ELISA DIG Detection System , 2006, Journal of immunoassay & immunochemistry.

[4]  Guodong Liu,et al.  Bioelectrochemical Magnetic Immunosensing of Trichloropyridinol: A Potential Insecticide Biomarker , 2006 .

[5]  C. O’Sullivan,et al.  Electrocatalytic oxidation of hydrazine at o-aminophenol grafted modified glassy carbon electrode: Reusable hydrazine amperometric sensor , 2006 .

[6]  Yuehe Lin,et al.  Amperometric glucose biosensor based on self-assembling glucose oxidase on carbon nanotubes , 2006 .

[7]  Guodong Liu,et al.  Biosensor based on self-assembling acetylcholinesterase on carbon nanotubes for flow injection/amperometric detection of organophosphate pesticides and nerve agents. , 2006, Analytical chemistry.

[8]  Dan Du,et al.  Electrochemical immunoassay for CA125 based on cellulose acetate stabilized antigen/colloidal gold nanoparticles membrane , 2006 .

[9]  J. Raba,et al.  Continuous-flow/stopped-flow system for enzyme immunoassay using a rotating bioreactor: determination of Chagas disease. , 2005, Biosensors & bioelectronics.

[10]  Agustín Costa-García,et al.  Amperometric detection in TMB/HRP-based assays , 2005, Analytical and bioanalytical chemistry.

[11]  J. Raba,et al.  Continuous-flow/stopped-flow system using an immunobiosensor for quantification of human serum IgG antibodies to Helicobacter pylori. , 2005, Analytical biochemistry.

[12]  Wassana Yantasee,et al.  Carbon nanotubes (CNTs) for the development of electrochemical biosensors. , 2005, Frontiers in bioscience : a journal and virtual library.

[13]  Levi A. Gheber,et al.  Construction of amperometric immunosensors based on the electrogeneration of a permeable biotinylated polypyrrole film. , 2004, Analytical chemistry.

[14]  H. Ju,et al.  Chemiluminescent immunosensor for CA19-9 based on antigen immobilization on a cross-linked chitosan membrane. , 2004, Journal of immunological methods.

[15]  Guo-Li Shen,et al.  Amperometric immunosensor for Schistosoma japonicum antigen using antibodies loaded on a nano-Au monolayer modified chitosan-entrapped carbon paste electrode , 2003 .

[16]  Jerry Lanfear,et al.  Immunohistochemical localization of PDE10A in the rat brain , 2003, Brain Research.

[17]  H. Akhavan-Tafti,et al.  Characterization of new fluorescent peroxidase substrates. , 2003, Talanta.

[18]  F. Fonnum,et al.  Evaluation of the probes 2',7'-dichlorofluorescin diacetate, luminol, and lucigenin as indicators of reactive species formation. , 2003, Biochemical pharmacology.

[19]  Yuehe Lin,et al.  Voltammetric detection of lead(II) and mercury(II) using a carbon paste electrode modified with thiol self-assembled monolayer on mesoporous silica (SAMMS). , 2003, The Analyst.

[20]  Y. L. Loukas,et al.  Determination of umbilical cord and maternal plasma concentrations of fentanyl by using novel spectrophotometric and chemiluminescence enzyme immunoassays , 2002 .

[21]  G. Shen,et al.  Renewable amperometric immunosensor for complement 3 (C3) assay in human serum , 2001 .

[22]  G. Shen,et al.  Renewable amperometric immunosensor for Schistosoma japonium antibody assay. , 2001, Analytical chemistry.

[23]  Huang-Hao Yang,et al.  Study of tetra-substituted amino aluminum phthalocyanine as a new red-region substrate for the fluorometric determination of peroxidase and hydrogen peroxide , 2001 .

[24]  Shusheng Zhang,et al.  Electrochemical detection for horseradish peroxidase-based enzyme immunoassay using p-aminophenol as substrate and its application in detection of plant virus , 2001 .

[25]  B. Limoges,et al.  Hybridization assay at a disposable electrochemical biosensor for the attomole detection of amplified human cytomegalovirus DNA. , 2000, Analytical biochemistry.

[26]  Qiu-Mao Chen,et al.  Application of Manganese-Tetrasulfonatophthalocyanine as a New Mimetic Peroxidase in the Determination of Hydrogen Peroxide in Marine Surface Water Samples with p-Hydroxyphenylacetic Acid as a Substrate , 2000 .

[27]  G. Shen,et al.  Renewable amperometric immunosensor based on paraffin-graphite-transferrin antiserum biocomposite for transferrin assay. , 2000, The Analyst.

[28]  Henkens,et al.  Multichannel Electrochemical Detection System for Quantitative Monitoring of PCR Amplification. , 1999, Clinical chemistry.

[29]  K. Jiao,et al.  Detection of ferritin in human serum with a MAP-H(2)O(2)-HRP voltammetric enzyme-linked immunoassay system. , 1999, Talanta.

[30]  Hongyuan Chen,et al.  Investigation of Voltammetric Enzyme-Linked Immunoassay Based on a New System of OAP-H2O2-HRP , 1999 .

[31]  Giuseppe Palleschi,et al.  3,3′,5,5′-Tetramethylbenzidine as electrochemical substrate for horseradish peroxidase based enzyme immunoassays. A comparative study , 1998 .

[32]  Y. N. He,et al.  Differential pulse voltammetric enzyme-linked immunoassay for the determination of Helicobacter pylori specific immunoglobulin G (IgG) antibody. , 1997, Talanta.

[33]  Y. Ci,et al.  Synthesis and Characteristics of a New Fluorogenic Substrate for Horseradish Peroxidase , 1996 .

[34]  X. Huang,et al.  The effects of media properties on the horseradish peroxidase-catalyzed fluorogenic reaction. , 1994, Talanta.

[35]  A. Kudelski,et al.  Electro-oxidation of o-aminophenol studied by cyclic voltammetry and surface enhanced Raman scattering (SERS) , 1993 .

[36]  Joseph Wang,et al.  On-line organic-phase enzyme detector , 1993 .

[37]  C. Barbero,et al.  Formation of a novel electroactive film by electropolymerization of ortho-aminophenol: Study of its chemical structure and formation mechanism. Electropolymerization of analogous compounds , 1989 .

[38]  R. Newton,et al.  Quantitation of related proteins by Western blot analysis. , 1988, Journal of immunological methods.

[39]  K. Zaitsu,et al.  New fluorogenic substrates for horseradish peroxidase: rapid and sensitive assays for hydrogen peroxide and the peroxidase. , 1980, Analytical biochemistry.