Finite Time Analysis of a Tri-Generation Cycle

A review of the literature indicates that current tri-generation cycles show low thermal performance, even when optimised for maximum useful output. This paper presents a Finite Time analysis of a tri-generation cycle that is based upon coupled power and refrigeration Carnot cycles. The analysis applies equally well to Stirling cycles or any cycle that exhibits isothermal heat transfer with the environment and is internally reversible. It is shown that it is possible to obtain a significantly higher energy utilisation factor with this type of cycle by considering the energy transferred during the isothermal compression and expansion processes as useful products thus making the energy utilisation larger than the enthalpy drop of the working fluid of the power cycle. The cycle is shown to have the highest energy utilisation factor when energy is supplied from a low temperature heat source and in this case the output is biased towards heating and cooling.

[1]  Peter Salamon,et al.  Finite time optimizations of a Newton’s law Carnot cycle , 1981 .

[2]  I. Glavan,et al.  THE ANALYSIS OF TRIGENERATION ENERGY SYSTEMS AND SELECTION OF THE BEST OPTION BASED ON CRITERIA OF GHG EMISSION, COST AND EFFICIENCY , 2012 .

[3]  Saffa Riffat,et al.  Design and optimisation of a small-scale tri-generation system , 2008 .

[4]  Bjarne Andresen,et al.  Maximum work from a finite reservoir by sequential Carnot cycles , 1981 .

[5]  Brian Agnew,et al.  Optimisation of a steady-flow Carnot cycle with external irreversibilities for maximum specific output , 1997 .

[6]  D. Yogi Goswami,et al.  Thermodynamic properties of ammonia–water mixtures for power-cycle applications , 1999 .

[7]  Harvey S. Leff,et al.  Thermal efficiency at maximum work output: New results for old heat engines , 1987 .

[8]  J H Horlock Approximate Analyses of Feed and District Heating Cycles for Steam Combined Heat and Power Plant , 1987 .

[9]  F. Curzon,et al.  Efficiency of a Carnot engine at maximum power output , 1975 .

[10]  Francis Meunier,et al.  Environmental assessment of biogas co- or tri-generation units by life cycle analysis methodology , 2005 .

[11]  Francis Meunier,et al.  Co- and tri-generation contribution to climate change control , 2002 .

[12]  S. C. Kaushik,et al.  Performance evaluation of irreversible stirling and ericsson heat pump cycles , 2002 .

[13]  I Potts,et al.  A finite time analysis of combined Carnot driving and cooling cycles optimised for maximum refrigeration effect with applications to absorption refrigeration systems , 2002 .

[14]  Peter Salamon,et al.  Maximum power from a cycling working fluid , 1982 .

[15]  Xiangping Chen,et al.  Integration and optimisation of bio-fuel micro-tri-generation with energy storage , 2013 .

[16]  Tom Gaertner,et al.  Advanced Engineering Thermodynamics , 2016 .

[17]  Savvas A. Tassou,et al.  Application of tri-generation systems to the food retail industry , 2007 .

[18]  L. W. Swanson Thermodynamic Optimization of Irreversible Power Cycles With Constant External Reservoir Temperatures , 1991 .

[19]  Mohammad Ameri,et al.  Thermodynamic analysis of a tri-generation system based on micro-gas turbine with a steam ejector refrigeration system , 2010 .

[20]  Roy C. Robertson,et al.  Thermodynamic Study of Ammonia-Water Heat Power Cycles, , 1953 .

[21]  Stanislaw Sieniutycz,et al.  Optimal work flux in sequential systems with complex heat exchange , 2001 .

[22]  J H Horlock,et al.  Thermodynamic Availability and its Application to Combined Heat and Power Plant , 1985 .

[23]  J. M. Gordon,et al.  Maximum power point characteristics of heat engines as a general thermodynamic problem , 1989 .

[24]  Roberto Frias,et al.  THE CURZON-AHLBORN EFFICIENCY OF COMBINED CYCLES , 2003 .