Fiberglass Grids as Sustainable Reinforcement of Historic Masonry

Fiber-reinforced composite (FRP) materials have gained an increasing success, mostly for strengthening, retrofitting and repair of existing historic masonry structures and may cause a significant enhancement of the mechanical properties of the reinforced members. This article summarizes the results of previous experimental activities aimed at investigating the effectiveness of GFRP (Glass Fiber Reinforced Polymers) grids embedded into an inorganic mortar to reinforce historic masonry. The paper also presents innovative results on the relationship between the durability and the governing material properties of GFRP grids. Measurements of the tensile strength were made using specimens cut off from GFRP grids before and after ageing in aqueous solution. The tensile strength of a commercially available GFRP grid has been tested after up 450 days of storage in deionized water and NaCl solution. A degradation in tensile strength and Young’s modulus up to 30.2% and 13.2% was recorded, respectively. This degradation indicated that extended storage in a wet environment may cause a decrease in the mechanical properties.

[1]  P. Gazzola,et al.  The Venice Charter: International Charter for the Conservation and Restoration of Monuments and Sites , 1964 .

[2]  Brahim Benmokrane,et al.  Durability of GFRP bars: a critical review of the literature , 2005 .

[3]  T. Triantafillou Strengthening of Masonry Structures Using Epoxy-Bonded FRP Laminates , 1998 .

[4]  JULIAN F. Johnson,et al.  Mechanical Properties of Polymers: The Influence of Molecular Weight and Molecular Weight Distribution , 1972 .

[5]  Natalino Gattesco,et al.  Diagonal compression tests on masonry walls strengthened with a GFRP mesh reinforced mortar coating , 2015, Bulletin of Earthquake Engineering.

[6]  Antonio Borri,et al.  Masonry wall panels with GFRP and steel-cord strengthening subjected to cyclic shear: An experimental study , 2014 .

[7]  V. Karbhari,et al.  Durability evaluation of moderate temperature cured E-glass/vinylester systems , 2004 .

[8]  T. Triantafillou,et al.  Seismic strengthening of masonry-infilled RC frames with TRM: Experimental study , 2015 .

[9]  Filip Van Rickstal,et al.  Grout injection of masonry, scientific approach and modeling , 2000 .

[10]  D. Bournas,et al.  Textile-reinforced mortar (TRM) versus fiber-reinforced polymers (FRP) in shear strengthening of concrete beams , 2015 .

[11]  C. Modena,et al.  Shear behavior of masonry panels strengthened by FRP laminates , 2002 .

[12]  M. Corradi,et al.  An experimental study on the influence of composite materials used to reinforce masonry ring beams , 2016 .

[13]  Müge Akkar Ercan How to Achieve Sustainable Conservation in the Historic Housing Neighborhoods of Istanbul? , 2010 .

[14]  Pedro F. Silva,et al.  Strengthening of Masonry Walls by FRP Structural Repointing , 2001 .

[15]  T. Uomoto DURABILITY DESIGN OF GFRP RODS FOR CONCRETE REINFORCEMENT , 2003 .

[16]  Elizabeth Vintzileou,et al.  Three-Leaf Stone Masonry Strengthened by Injecting Cement Grouts , 1995 .

[17]  Paul J. Hogg,et al.  Temperature and environmental effects on glass fibre rebar: modulus, strength and interfacial bond strength with concrete , 2005 .

[18]  M. Corradi,et al.  Behavior of thin masonry arches repaired using composite materials , 2016 .

[19]  José M. Álvarez,et al.  Compositional changes in lime-based mortars exposed to different environments , 2005 .

[20]  Carl R. Schultheisz,et al.  Effects of environmental aging on the properties of pultruded GFRP , 1999 .

[21]  J. Lanas,et al.  Masonry repair lime-based mortars: factors affecting the mechanical behavior , 2003 .

[22]  Luca Righetti,et al.  Durability of GFRP grids for masonry structures , 2016 .

[23]  S. Bagherpour Fibre Reinforced Polyester Composites , 2012 .

[24]  Antonio Borri,et al.  Shear strengthening of wall panels through jacketing with cement mortar reinforced by GFRP grids , 2014 .

[25]  B. Benmokrane,et al.  Durability Gap Analysis for Fiber-Reinforced Polymer Composites in Civil Infrastructure , 2003 .

[26]  Thanasis Triantafillou,et al.  Analytical modeling of masonry-infilled RC frames retrofitted with textile-reinforced mortar , 2015 .

[27]  Thanasis C. Triantafillou,et al.  Textile reinforced mortar (TRM) versus FRP as strengthening material of URM walls: out-of-plane cyclic loading , 2008 .

[28]  Julio F. Davalos,et al.  Accelerated aging tests for evaluations of durability performance of FRP reinforcing bars for concrete structures , 2007 .

[29]  Claudio Modena,et al.  Repair and investigation techniques for stone masonry walls , 1997 .