Local tissue attenuation images based on pulsed-echo ultrasound scans

The original conventional B scan is traversed, one pixel at a time. In the vicinity of each pixel, a uniform area is determined and average attenuation is computed utilizing an extended modified Prony approach. B scans of tissue mimicking phantoms and in vivo human liver scans are used to illustrate the performance of the proposed algorithm. The results show good agreement between estimated and known attenuation values. Clinical studies demonstrate significant potential of the technique, in particular for diagnosis of diffuse liver disease.<<ETX>>

[1]  C. Riely,et al.  Quantitative US attenuation in normal liver and in patients with diffuse liver disease: importance of fat. , 1986, Radiology.

[2]  K J Parker,et al.  Ultrasonic attenuation and absorption in liver tissue. , 1983, Ultrasound in medicine & biology.

[3]  Raj Mittra,et al.  Problems and solutions associated with Prony's method for processing transient data , 1978 .

[4]  W. Huggins,et al.  Best least-squares representation of signals by exponentials , 1968 .

[5]  P He,et al.  Attenuation estimation on phantoms--a stability test. , 1986, Ultrasonic imaging.

[6]  F. Dunn,et al.  Compilation of empirical ultrasonic properties of mammalian tissues. II. , 1980, The Journal of the Acoustical Society of America.

[7]  Y. Itzchak,et al.  Ultrasonography in the staging of Hodgkin's disease: lymphangiographic correlation. , 1986, European journal of cancer & clinical oncology.

[8]  James F. Greenleaf,et al.  CLINICAL IMAGING WITH TRANSMISSIVE ULTRASONIC COMPUTERIZED TOMOGRAPHY , 1981 .

[9]  J. Cardoso,et al.  Diffraction Correction in Pulse-Echo Attenuation Measurements , 1983 .

[10]  Michael F. Insana,et al.  Analysis of ultrasound image texture via generalized rician statistics , 1986 .

[11]  Raj Mittra,et al.  Correction to "Problems and solutions associated with Prony's method for processing transient data" , 1980 .

[12]  Kevin J. Parker,et al.  Quantitative Tissue Characterzation Based on Pulsed-Echo Ultrasound Scans , 1986, IEEE Transactions on Biomedical Engineering.

[13]  C. Burckhardt Speckle in ultrasound B-mode scans , 1978, IEEE Transactions on Sonics and Ultrasonics.

[14]  Mostafa Fatemi,et al.  Digital Processing for Improvement of Ultrasonic Abdominal Images , 1983, IEEE Transactions on Medical Imaging.

[15]  R. F. Wagner,et al.  Statistics of Speckle in Ultrasound B-Scans , 1983, IEEE Transactions on Sonics and Ultrasonics.

[16]  F. Dunn,et al.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. , 1978, The Journal of the Acoustical Society of America.