Material considerations for intervertebral disc replacement implants.

Cervical and lumbar disc replacements are being performed with increasing frequency. Much of the background for the development for these implants is drawn from the literature of other joint replacements that have been in evolution and use for decades. Important variables for the function and longevity of such disc arthroplasty implants are clearly defined by the material properties of the components used for their production. The most frequently considered materials are cobalt-chrome alloys, titanium alloys, stainless steels, polyethylene, polyurethane and ceramics. In addition to implant materials, the interfaces of such materials must be considered. The bearing surfaces of an implant, in particular, are at risk of wear and failure. Overall, successful, long-term total disc arthroplasty requires a thorough understanding of biomaterials and how they can be used to achieve their desired goals.

[1]  M. Müller The benefits of metal-on-metal total hip replacements. , 1995, Clinical Orthopaedics and Related Research.

[2]  L. Dorr,et al.  Total Hip Arthroplasty with Use of the Metasul Metal-on-Metal Articulation: Four to Seven-Year Results* , 2000, The Journal of bone and joint surgery. American volume.

[3]  S. Goodman,et al.  In vitro, in vivo, and tissue retrieval studies on particulate debris. , 1998, Clinical orthopaedics and related research.

[4]  Joshua J Jacobs,et al.  Spinal Implant Debris-Induced Osteolysis , 2003, Spine.

[5]  M. Reich,et al.  Systemic effects of implanted prostheses made of cobalt-chromium alloys , 2004, Archives of Orthopaedic and Trauma Surgery.

[6]  C. Sledge,et al.  Early failure of Hylamer acetabular inserts due to eccentric wear. , 1996, The Journal of arthroplasty.

[7]  Stomatology,et al.  Biocompatibility of Co-Cr-Ni Alloys , 1988, NATO ASI Series.

[8]  F. Löer,et al.  Trace element burdening of human tissues due to the corrosion of hip-joint prostheses made of cobalt-chromium alloys , 2004, Archives of orthopaedic and traumatic surgery.

[9]  N. Baldini,et al.  Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results. , 2003, Journal of biomedical materials research. Part A.

[10]  B. Cunningham,et al.  General Principles of Total Disc Replacement Arthroplasty: Seventeen Cases in a Nonhuman Primate Model , 2003, Spine.

[11]  D. Bartel,et al.  The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. , 1986, The Journal of bone and joint surgery. American volume.

[12]  Joshua J. Jacobs,et al.  Corrosion of metal orthopaedic implants. , 1998, The Journal of bone and joint surgery. American volume.

[13]  A. Sarmiento,et al.  Interface corrosion of a modular head total hip prosthesis. , 1992, The Journal of arthroplasty.

[14]  P. Campbell,et al.  Cobalt and Chromium Concentrations in Patients With Metal on Metal Total Hip Replacements , 1996, Clinical orthopaedics and related research.

[15]  H A Yuan,et al.  The artificial disc: theory, design and materials. , 1996, Biomaterials.

[16]  R. Chiesa,et al.  In vivo wear of three types of metal on metal hip prostheses during two decades of use. , 1996, Clinical orthopaedics and related research.

[17]  P. Campbell,et al.  Semi-quantitative analysis of cytokines in MM THR tissues and their relationship to metal particles. , 2003, Biomaterials.

[18]  H. Bertram,et al.  Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. , 1990, Clinical orthopaedics and related research.

[19]  H. Weber,et al.  Cobalt Chromium Molybdenum Metal Combination for Modular Hip Prostheses , 1996, Clinical orthopaedics and related research.

[20]  P. McAfee,et al.  Biomaterial Optimization in Total Disc Arthroplasty , 2003, Spine.

[21]  M. Péoc'h,et al.  Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement* , 2000, The Journal of bone and joint surgery. American volume.

[22]  C. Jewett,et al.  Radiation and chemical crosslinking promote strain hardening behavior and molecular alignment in ultra high molecular weight polyethylene during multi-axial loading conditions. , 1999, Biomaterials.

[23]  T. Schmalzried,et al.  The risk of cancer following total hip or knee arthroplasty. , 2001, The Journal of bone and joint surgery. American volume.

[24]  F. Kummer,et al.  Alternative bearing surfaces for total joint arthroplasty. , 1998, The Journal of the American Academy of Orthopaedic Surgeons.

[25]  A. Edidin,et al.  Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. , 1999, Biomaterials.

[26]  D. Howie,et al.  The response to particulate debris. , 1993, The Orthopedic clinics of North America.

[27]  A. Massè,et al.  Ion release and chromosomal damage from total hip prostheses with metal-on-metal articulation. , 2003, Journal of biomedical materials research. Part B, Applied biomaterials.

[28]  J. Jacobs,et al.  Alternative bearing surfaces in total joint replacement , 1998 .

[29]  P. Campbell,et al.  Metal on metal total hip replacement workshop consensus document. , 1996, Clinical orthopaedics and related research.

[30]  A Walter,et al.  On the material and the tribology of alumina-alumina couplings for hip joint prostheses. , 1992, Clinical orthopaedics and related research.

[31]  S. Hopfer,et al.  Cobalt, chromium, and nickel concentrations in body fluids of patients with porous‐coated knee or hip prostheses , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[32]  M. Pourbaix Electrochemical corrosion of metallic biomaterials. , 1984, Biomaterials.

[33]  D. Pienkowski,et al.  Compressive creep characteristics of extruded ultrahigh-molecular-weight polyethylene. , 1998, Journal of biomedical materials research.

[34]  P. Anderson,et al.  Wear Analysis of the Bryan Cervical Disc Prosthesis , 2003, Spine.

[35]  J. Jacobs,et al.  Metal sensitivity in patients with orthopaedic implants. , 2001, The Journal of bone and joint surgery. American volume.

[36]  M Wagner,et al.  Medium-Term Results of a Modern Metal-on-Metal System in Total Hip Replacement , 2000, Clinical orthopaedics and related research.

[37]  B. Vernon‐roberts,et al.  The Biologic Response to Particles From a Lumbar Disc Prosthesis , 2002, Spine.

[38]  J. Galante,et al.  Wear Debris in Total Joint Replacements , 1994, The Journal of the American Academy of Orthopaedic Surgeons.