Microfluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays

We propose a unique method for cell sorting, “Ephesia,” using columns of biofunctionalized superparamagnetic beads self-assembled in a microfluidic channel onto an array of magnetic traps prepared by microcontact printing. It combines the advantages of microfluidic cell sorting, notably the application of a well controlled, flow-activated interaction between cells and beads, and those of immunomagnetic sorting, notably the use of batch-prepared, well characterized antibody-bearing beads. On cell lines mixtures, we demonstrated a capture yield better than 94%, and the possibility to cultivate in situ the captured cells. A second series of experiments involved clinical samples—blood, pleural effusion, and fine needle aspirates— issued from healthy donors and patients with B-cell hematological malignant tumors (leukemia and lymphoma). The immunophenotype and morphology of B-lymphocytes were analyzed directly in the microfluidic chamber, and compared with conventional flow cytometry and visual cytology data, in a blind test. Immunophenotyping results using Ephesia were fully consistent with those obtained by flow cytometry. We obtained in situ high resolution confocal three-dimensional images of the cell nuclei, showing intranuclear details consistent with conventional cytological staining. Ephesia thus provides a powerful approach to cell capture and typing allowing fully automated high resolution and quantitative immunophenotyping and morphological analysis. It requires at least 10 times smaller sample volume and cell numbers than cytometry, potentially increasing the range of indications and the success rate of microbiopsy-based diagnosis, and reducing analysis time and cost.

[1]  Mehmet Toner,et al.  Isolation and Characterization of Circulating Tumor Cells from Patients with Localized and Metastatic Prostate Cancer , 2010, Science Translational Medicine.

[2]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[3]  K. Jensen,et al.  Cells on chips , 2006, Nature.

[4]  G. Hortobagyi Trastuzumab in the treatment of breast cancer. , 2005, The New England journal of medicine.

[5]  K. Geisinger,et al.  Diagnosis and subclassification of primary and recurrent lymphoma. The usefulness and limitations of combined fine-needle aspiration cytomorphology and flow cytometry. , 2000, American journal of clinical pathology.

[6]  J. Dick,et al.  Human acute myeloid leukemia is organized as a hierarchy that originates from a primitive hematopoietic cell , 1997, Nature Medicine.

[7]  G. Whitesides,et al.  Soft Lithography. , 1998, Angewandte Chemie.

[8]  M. Cretich,et al.  A new absorbed coating for DNA fragment analysis by capillary electrophoresis , 2000, Electrophoresis.

[9]  S. Digumarthy,et al.  Isolation of rare circulating tumour cells in cancer patients by microchip technology , 2007, Nature.

[10]  J. Rossier,et al.  Injection and flow control system for microchannels. , 2004, Lab on a chip.

[11]  K. Dorfman,et al.  Motion of single long DNA molecules through arrays of magnetic columns , 2005, Electrophoresis.

[12]  Hakho Lee,et al.  Rapid detection and profiling of cancer cells in fine-needle aspirates , 2009, Proceedings of the National Academy of Sciences.

[13]  J. Sturm,et al.  Continuous Particle Separation Through Deterministic Lateral Displacement , 2004, Science.

[14]  T. Kroll,et al.  Monitoring the response of circulating epithelial tumor cells to adjuvant chemotherapy in breast cancer allows detection of patients at risk of early relapse. , 2008, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[15]  Robert H. Austin,et al.  Hydrodynamic metamaterials: Microfabricated arrays to steer, refract, and focus streams of biomaterials , 2008, Proceedings of the National Academy of Sciences.

[16]  I. Ramzy,et al.  Large B‐cell lymphomas: Fine‐needle aspiration plays an important role in initial diagnosis of cases which are falsely negative by flow cytometry , 2002, Diagnostic cytopathology.

[17]  Jean-Louis Viovy,et al.  Self-Assembled Magnetic Matrices for DNA Separation Chips , 2002, Science.

[18]  Mehmet Toner,et al.  Blood-on-a-chip. , 2005, Annual review of biomedical engineering.

[19]  Robert H. Austin,et al.  Continuous microfluidic immunomagnetic cell separation , 2004 .

[20]  R. Austin,et al.  Force mapping in epithelial cell migration. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[21]  Dorian Liepmann,et al.  Biomimetic technique for adhesion-based collection and separation of cells in a microfluidic channel. , 2005, Lab on a chip.

[22]  Unyoung Kim,et al.  Multitarget magnetic activated cell sorter , 2008, Proceedings of the National Academy of Sciences.

[23]  Shi-shang Guo,et al.  Response of super-paramagnetic beads in microfluidic devices with integrated magnetic micro-columns , 2006 .

[24]  J. Walloch,et al.  Multiparameter immunophenotypic analysis of fine needle aspiration biopsies and other hematologic specimens by laser scanning cytometry. , 1997, Acta cytologica.

[25]  J. Jorgensen State of the Art Symposium: Flow cytometry in the diagnosis of lymphoproliferative disorders by fine‐needle aspiration , 2005, Cancer.

[26]  J. Kearney,et al.  B1 cells: similarities and differences with other B cell subsets. , 2001, Current opinion in immunology.

[27]  Andreas Radbruch,et al.  High gradient magnetic cell separation with MACS. , 1990, Cytometry.

[28]  Anne Vincent-Salomon,et al.  Clinical Significance of Immunocytochemical Detection of Tumor Cells Using Digital Microscopy in Peripheral Blood and Bone Marrow of Breast Cancer Patients , 2004, Clinical Cancer Research.

[29]  Charles Kervrann,et al.  Optimal Spatial Adaptation for Patch-Based Image Denoising , 2006, IEEE Transactions on Image Processing.

[30]  J. Thiery,et al.  A relevant immunomagnetic assay to detect and characterize epithelial cell adhesion molecule‐positive cells in bone marrow from patients with breast carcinoma , 2004, Cancer.

[31]  J. Bibette,et al.  Self-assembled magnetic nanowires made irreversible by polymer bridging. , 2005, Langmuir : the ACS journal of surfaces and colloids.

[32]  Jonathan W. Uhr,et al.  Tumor Cells Circulate in the Peripheral Blood of All Major Carcinomas but not in Healthy Subjects or Patients With Nonmalignant Diseases , 2004, Clinical Cancer Research.

[33]  Kevin D Dorfman,et al.  Quantitative microfluidic separation of DNA in self-assembled magnetic matrixes. , 2004, Analytical chemistry.

[34]  A. Weiss,et al.  Detection and characterization of carcinoma cells in the blood. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[35]  D. Das Value and limitations of fine‐needle aspiration cytology in diagnosis and classification of lymphomas: A review , 1999, Diagnostic cytopathology.

[36]  Wu,et al.  Field-Induced Structures in Ferrofluid Emulsions. , 1995, Physical review letters.

[37]  Mehmet Toner,et al.  A microfluidic device for practical label-free CD4(+) T cell counting of HIV-infected subjects. , 2007, Lab on a chip.

[38]  D. de Jong,et al.  A new non-Hodgkin's B-cell line (DoHH2) with a chromosomal translocation t(14;18)(q32;q21). , 1991, Leukemia.

[39]  R. Demay Practical Principles of Cytopathology , 1999 .